Stretchable, Sensitive Strain Sensors with a Wide Workable Range and Low Detection Limit for Wearable Electronic Skins

Author(s):  
Wei Zhai ◽  
Jingzhan Zhu ◽  
Ziqi Wang ◽  
Yi Zhao ◽  
Pengfei Zhan ◽  
...  
2019 ◽  
Vol 7 (14) ◽  
pp. 4199-4209 ◽  
Author(s):  
Jiefeng Gao ◽  
Lisheng Wu ◽  
Zheng Guo ◽  
Jiye Li ◽  
Cong Xu ◽  
...  

It is desirable to develop strain sensors with large stretchability, high sensitivity, and good anti-corrosive properties, due to their promising applications in wearable electronics.


Author(s):  
J. J. Domanski ◽  
P. L. Haire ◽  
T.J. Sheets

AbstractAverage residue Ievels of DDT + TDE in flue-cured tobacco decreased from 6.1 ppm in 1970 to 0.85 ppm in 1972. DDT + TDE residues in Burley also dropped sharply from previous levels. In 1972 one sample from Kentucky contained 8.17 ppm; all other Burley samples were less than 0.25 ppm. DDT + TDE residues also declined in fire-cured and air-cured types; of these samples Tennessee dark air-cured tobacco contained the highest average residue (3.5 ppm of DDT + TDE). In 1972 over 90 % of the flue-cured samples were positive for toxaphene. Since each of our samples was a composite of tobacco from 10 farmers, we cannot conclude from this result that 90 % of the individual piles contained toxaphene. Significant amounts of toxaphene were found in other types also; for example, 50 % of the 1972 Burley samples had toxaphene concentrations greater than 0.5 ppm. Average endosulfan levels decreased between 1970 and 1972 in flue-cured and Burley tobaccos. However, in all of the dark air and dark fire-cured samples from Tennessee endosulfan residues exceeded 5 ppm. Average endrin residues were at or near the low detection limit in alI samples except fire-cured and dark air-cured tobacco from Tennessee; these averaged 0.26 and 0.17 ppm, respectively.


2021 ◽  
Author(s):  
Bo Liu ◽  
Luanying Yang ◽  
Gang Wang ◽  
Sha He ◽  
Xiaobo Wang ◽  
...  

A simple and low-cost electrochemical CEA immunosensor was investigated via the self-polymerization of dopamine and a dithiol compound spacer for the covalent immobilization of antibodies. The designed CEA immunosensor exhibited a linear response and a low detection limit.


Nanomaterials ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1701
Author(s):  
Ken Suzuki ◽  
Ryohei Nakagawa ◽  
Qinqiang Zhang ◽  
Hideo Miura

In this study, a basic design of area-arrayed graphene nanoribbon (GNR) strain sensors was proposed to realize the next generation of strain sensors. To fabricate the area-arrayed GNRs, a top-down approach was employed, in which GNRs were cut out from a large graphene sheet using an electron beam lithography technique. GNRs with widths of 400 nm, 300 nm, 200 nm, and 50 nm were fabricated, and their current-voltage characteristics were evaluated. The current values of GNRs with widths of 200 nm and above increased linearly with increasing applied voltage, indicating that these GNRs were metallic conductors and a good ohmic junction was formed between graphene and the electrode. There were two types of GNRs with a width of 50 nm, one with a linear current–voltage relationship and the other with a nonlinear one. We evaluated the strain sensitivity of the 50 nm GNR exhibiting metallic conduction by applying a four-point bending test, and found that the gauge factor of this GNR was about 50. Thus, GNRs with a width of about 50 nm can be used to realize a highly sensitive strain sensor.


Author(s):  
Ziyu Wang ◽  
Meiyun Xu ◽  
Nan Zhang ◽  
Jian-Bin Pan ◽  
Xinqi Wu ◽  
...  

A mechanism of co-reactive group poisoning (CGP) was discovered for designing efficient I2 vapor sensors for early warning of a nuclear emergency, which give an ultra-low detection limit of 0.13 ppt as well as high selectivity.


2016 ◽  
Vol 18 (34) ◽  
pp. 23795-23802 ◽  
Author(s):  
Xiaolong Wang ◽  
Lu Zhou ◽  
Wei Lai ◽  
Tao Jiang ◽  
Jun Zhou

We present a recyclable SERS-based immunoassay for CA19-9 with a low detection limit of 5 U mL−1. The linking between TiO2-NTs and 4MBA was destroyed by catalyzing 4MBA into 4-sulfobenzoate upon UV irradiation, which was clarified by UPLC/ESI-tqMS and density functional theory.


RSC Advances ◽  
2016 ◽  
Vol 6 (3) ◽  
pp. 1722-1728 ◽  
Author(s):  
Pankaj Gupta ◽  
Munetaka Oyama ◽  
Rajendra N. Goyal

Electrochemical oxidation of 8-hydroxydeoxyguanosine (8-OHdG) and its detection with low detection limit is reported at pyrolytic graphite electrode.


The Analyst ◽  
2015 ◽  
Vol 140 (10) ◽  
pp. 3557-3564 ◽  
Author(s):  
Yaoguang Wang ◽  
Yueyun Li ◽  
Hongmin Ma ◽  
Aiping Guo ◽  
Bin Du ◽  
...  

An ultrasensitive electrochemical immunosensor was developed for detecting CD146. rGO-TEPA enhanced the loading capacity of Ab1 and facilitated the electron transfer. Au and Pd nanoparticles on the TiO2 colloidal sphere facilitated the decomposition of H2O2. The immunosensor exhibited an extremely low detection limit of 1.6 pg mL−1 for CD146.


Sign in / Sign up

Export Citation Format

Share Document