Membrane Fouling and Molecular Weight Cutoff Effects on the Partitioning of Pectinesterase

1996 ◽  
Vol 44 (8) ◽  
pp. 2091-2095 ◽  
Author(s):  
Rami Snir ◽  
Louise Wicker ◽  
Phillip E. Koehler ◽  
Kevin A. Sims
2017 ◽  
Vol 23 (7) ◽  
pp. 637-645 ◽  
Author(s):  
Chiranjit Bhattacharjee ◽  
Vinod K Saxena ◽  
Suman Dutta

Raw watermelon juice was concentrated in a laboratory-scale flat-plate ultrafiltration system incorporating polyethersulfone membranes with a molecular weight cutoff of 5 kDa. The experiments have been carried out over a wide range of transmembrane pressures (100–300 kPa). The effect of ultrafiltration with molecular weight cutoff of 5 kDa polyethersulfone membrane on concentrate properties is reported. The total soluble solid content of the permeate was found to be very good, while the ascorbic acid content was on the lower side as compared to feed. The analyses of flux decay according to fouling models reported in the literature revealed that the formation of a cake layer covering the entire surface of the membrane is the main cause of the membrane fouling.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2021 ◽  
Author(s):  
Amira Abdelrasoul

The low-pressure membrane applications are considered to be the most effective and sustainable methods of addressing environmental problems in treating water and wastewater that meets or exceed stringent environmental standards. Nevertheless, membrane fouling is one of the primary operational concerns that is currently hindering a more widespread application of ultrafiltration (UF) with a variety of contaminants. Membrane fouling leads to higher operating costs, higher energy demand, reduced membrane life time, and increased cleaning frequency. As a consequence, an efficient and well-planned UF process is becoming a necessity for consistent and long-term monetary returns. Examining the source and mechanisms of foulant attachment to the membrane’s surface is critical when it comes to the research of membrane fouling and its potential practical implementation. A mathematical model was developed in this study in order to predict the amount of fouling based on an analysis of particle attachments. This model was developed using both homogeneous and heterogeneous membranes, with a uniform and non-uniform pore sizes for the UF of simulated latex effluent with a wide range of particle size distribution. The objective of this mathematical model was to effectively identify and address the common shortcomings of previous fouling models, and to account for the existing chemical attachments in membrane fouling. The mathematical model resulting from this study was capable of accurately predicting the mass of fouling retained by the membrane and the increase in transmembrane pressure (TMP). In addition, predictive models of fouling attachments were derived and now form an extensive set of mathematical models necessary for the prediction of membrane fouling at a given operating condition, as well as, the various membrane surface charges. Polycarbonate and Polysulfone flat membranes, with pore sizes of 0.05 μm and a molecular weight cut off of 60,000 respectively, were used in the experimental designs under a constant feed flow rate and a cross-flow mode in UF of the simulated latex paint effluent. The TMP estimated from the model agreed with the experimentally measured values at different operating conditions, mostly within 5.0 - 8.0 % error, and up to 13.0% error for the uniform, and non-uniform pore size membranes, respectively. Furthermore, different types of membranes with a variety of molecular weight cut-off (MWCO) values were tested so as to evaluate the accuracy of the models for a generalized application. In addition , a power consumption model, incorporating fouling attachment as well as chemical and physical factors in membrane fouling, was developed in order to ensure accurate prediction and scale-up. Innovative remediation techniques were likewise developed and applied in order to minimize membrane fouling, enhance the membrane performance, and save energy. Fouling remediation methodologies included the pre-treating of the latex effluent, so as to limit its fouling propensity by using different types of surfactants as cationic and anionic, in addition to the pH change. The antifouling properties of the membranes were improved through the implementation of the membrane pH treatment and anionic surfactant treatment. Increasing the ionic strength of latex effluent or enhancing the membrane surface hydrophilicity facilitated a significant increase in the cumulative permeate flux, a substantial decrease in the total mass of fouling, and a noticeable decrease in the specific power consumption.


2019 ◽  
Vol 137 (5) ◽  
pp. 48327 ◽  
Author(s):  
Priyesh Wagh ◽  
John Spencer ◽  
Brandon Steele ◽  
Isabel C. Escobar

1980 ◽  
Vol 26 (11) ◽  
pp. 1334-1339 ◽  
Author(s):  
M. Trudel ◽  
P. Payment

Large volumes of rubella virus were produced in Vero cell monolayers which were grown in the Corbeil-Bellco TM system. Infectious tissue culture fluids were concentrated at least 600 times in less than 4 h by ultrafiltration on hollow fibers with a molecular weight cutoff of 100 000. Recovery of the hemagglutinating activity was 75%. Rubella virus was purified by three successive sucrose density gradient centrifugations using a combination of discontinuous and linear gradients. Specific activity was increased 1000-fold.


2017 ◽  
Vol 17 (4) ◽  
pp. 1178-1184 ◽  
Author(s):  
M. Schulz ◽  
J. Winter ◽  
H. Wray ◽  
B. Barbeau ◽  
P. Bérubé

The natural organic matter (NOM) removal efficiency and regeneration behavior of ion-exchange filters with promoted biological activity (BIEX) was compared to operation where biological activity was suppressed (i.e. abiotic conditions). The impact of BIEX pre-treatment on fouling in subsequent ultrafiltration was also investigated. Biological operation enhanced NOM removal by approximately 50% due to an additional degradation of smaller humic substances, building blocks and low molecular weight acids. Promotion of biological activity significantly increased the time to breakthrough of the filters and, therefore, is expected to lower the regeneration frequency as well as the amount of regenerate of which to dispose. Pre-treatment using BIEX filters resulted in a significant decrease in total and irreversible fouling during subsequent ultrafiltration. The decrease was attributed to the effective removal of medium and low molecular weight NOM fractions. The results indicate that BIEX filtration is a robust, affordable and easy-to-operate pre-treatment approach to minimize fouling in ultrafiltration systems and enhance the quality of the produced permeate.


Sign in / Sign up

Export Citation Format

Share Document