scholarly journals Imaging low-dimensional nanostructures by very low voltage scanning electron microscopy: ultra-shallow topography and depth-tunable material contrast

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Laura Zarraoa ◽  
María U. González ◽  
Álvaro San Paulo

Abstract We demonstrate the implications of very low voltage operation (<1 kV) of a scanning electron microscope for imaging low-dimensional nanostructures where standard voltages (2–5 kV) involve a beam penetration depth comparable to the cross-section of the nanostructures. In this common situation, image sharpness, contrast quality and resolution are severely limited by emission of secondary electrons far from the primary beam incidence point. Oppositely, very low voltage operation allows reducing the beam-specimen interaction to an extremely narrow and shallow region around the incidence point, enabling high-resolution and ultra-shallow topographic contrast imaging by high-angle backscattered electrons detection on the one hand, and depth-tunable material contrast imaging by low-angle backscattered electrons detection on the other. We describe the performance of these imaging approaches on silicon nanowires obtained by the vapor-liquid-solid mechanism. Our experimental results, supported by Monte Carlo simulations of backscattered electrons emission from the nanowires, reveal the self-assembly of gold-silica core-shell nanostructures at the nanowire tips without any ad-hoc thermal oxidation step. This result demonstrates the capacity of very low voltage operation to provide optimum sharpness, contrast and resolution in low-dimensional nanostructures and to gather information about nanoscaled core-shell conformations otherwise impossible to obtain by standard scanning electron microscopy alone.

Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7511
Author(s):  
Jonathan Chuah ◽  
Anjam Khursheed

This paper presents the design of a reflection electron energy spectrometer (REELS) attachment for low voltage scanning electron microscopy (LVSEM) applications. The design is made by carrying out a scattered electron trajectory ray paths simulation. The spectrometer attachment is small enough to fit on the specimen stage of an SEM, and aims to acquire nanoscale spatially resolved REELS information. It uses a retarding field electrostatic toroidal sector energy analyzer design, which is able to lower the kinetic energies of elastically backscattered electrons to pass energies of 10 eV or less. For the capture of 1 keV BSEs emitted in the polar angular range between 40 to 50°, direct ray-tracing simulations predict that the spectrometer attachment will have an energy resolution of around 0.4 eV at a pass energy of 10 eV, and 0.2 eV at a pass energy of 5 eV. This predicted performance will make it a suitable REELS attachment for SEMs that use field emission electron sources.


Author(s):  
Klaus-Ruediger Peters

A new generation of high performance field emission scanning electron microscopes (FSEM) is now commercially available (JEOL 890, Hitachi S 900, ISI OS 130-F) characterized by an "in lens" position of the specimen where probe diameters are reduced and signal collection improved. Additionally, low voltage operation is extended to 1 kV. Compared to the first generation of FSEM (JE0L JSM 30, Hitachi S 800), which utilized a specimen position below the final lens, specimen size had to be reduced but useful magnification could be impressively increased in both low (1-4 kV) and high (5-40 kV) voltage operation, i.e. from 50,000 to 200,000 and 250,000 to 1,000,000 x respectively.At high accelerating voltage and magnification, contrasts on biological specimens are well characterized1 and are produced by the entering probe electrons in the outmost surface layer within -vl nm depth. Backscattered electrons produce only a background signal. Under these conditions (FIG. 1) image quality is similar to conventional TEM (FIG. 2) and only limited at magnifications >1,000,000 x by probe size (0.5 nm) or non-localization effects (%0.5 nm).


Author(s):  
S. J. Krause ◽  
W.W. Adams ◽  
S. Kumar ◽  
T. Reilly ◽  
T. Suziki

Scanning electron microscopy (SEM) of polymers at routine operating voltages of 15 to 25 keV can lead to beam damage and sample image distortion due to charging. Imaging polymer samples with low accelerating voltages (0.1 to 2.0 keV), at or near the “crossover point”, can reduce beam damage, eliminate charging, and improve contrast of surface detail. However, at low voltage, beam brightness is reduced and image resolution is degraded due to chromatic aberration. A new generation of instruments has improved brightness at low voltages, but a typical SEM with a tungsten hairpin filament will have a resolution limit of about 100nm at 1keV. Recently, a new field emission gun (FEG) SEM, the Hitachi S900, was introduced with a reported resolution of 0.8nm at 30keV and 5nm at 1keV. In this research we are reporting the results of imaging coated and uncoated polymer samples at accelerating voltages between 1keV and 30keV in a tungsten hairpin SEM and in the Hitachi S900 FEG SEM.


Author(s):  
Arthur V. Jones

In comparison with the developers of other forms of instrumentation, scanning electron microscope manufacturers are among the most conservative of people. New concepts usually must wait many years before being exploited commercially. The field emission gun, developed by Albert Crewe and his coworkers in 1968 is only now becoming widely available in commercial instruments, while the innovative lens designs of Mulvey are still waiting to be commercially exploited. The associated electronics is still in general based on operating procedures which have changed little since the original microscopes of Oatley and his co-workers.The current interest in low-voltage scanning electron microscopy will, if sub-nanometer resolution is to be obtained in a useable instrument, lead to fundamental changes in the design of the electron optics. Perhaps this is an opportune time to consider other fundamental changes in scanning electron microscopy instrumentation.


Author(s):  
W.W. Adams ◽  
G. Price ◽  
A. Krause

It has been shown that there are numerous advantages in imaging both coated and uncoated polymers in scanning electron microscopy (SEM) at low voltages (LV) from 0.5 to 2.0 keV compared to imaging at conventional voltages of 10 to 20 keV. The disadvantages of LVSEM of degraded resolution and decreased beam current have been overcome with the new generation of field emission gun SEMs. In imaging metal coated polymers in LVSEM beam damage is reduced, contrast is improved, and charging from irregularly shaped features (which may be unevenly coated) is reduced or eliminated. Imaging uncoated polymers in LVSEM allows direct observation of the surface with little or no charging and with no alterations of surface features from the metal coating process required for higher voltage imaging. This is particularly important for high resolution (HR) studies of polymers where it is desired to image features 1 to 10 nm in size. Metal sputter coating techniques produce a 10 - 20 nm film that has its own texture which can obscure topographical features of the original polymer surface. In examining thin, uncoated insulating samples on a conducting substrate at low voltages the effect of sample-beam interactions on image formation and resolution will differ significantly from the effect at higher accelerating voltages. We discuss here sample-beam interactions in single crystals on conducting substrates at low voltages and also present the first results on HRSEM of single crystal morphologies which show some of these effects.


2002 ◽  
Vol 10 (2) ◽  
pp. 22-23 ◽  
Author(s):  
David C Joy ◽  
Dale E Newbury

Low Voltage Scanning Electron Microscopy (LVSEM), defined as operation in the energy range below 5 keV, has become perhaps the most important single operational mode of the SEM. This is because the LVSEM offers advantages in the imaging of surfaces, in the observation of poorly conducting and insulating materials, and for high spatial resolution X-ray microanalysis. These benefits all occur because a reduction in the energy Eo of the incident beam leads to a rapid fall in the range R of the electrons since R ∼k.E01.66. The reduction in the penetration of the beam has important consequences.