scholarly journals Frequency and component analysis of contaminants generated in preparation of anticancer agents using closed system drug transfer devices (CSTDs)

2022 ◽  
Vol 12 (1) ◽  
Author(s):  
Satomi Sumikawa ◽  
Yoshihiro Yakushijin ◽  
Kenjiro Aogi ◽  
Takuya Yano ◽  
Hiroki ◽  
...  

AbstractOccupational exposure of anticancer agents during their preparation has been recognized as a serious hazard. Closed system drug transfer devices (CSTDs) enable “safe” preparation of agents for medical personnel and ensure a safe hospital environment. However, artificial particles of infusion materials have been reported during CSTD use. Here, the incidence of insoluble fine particles during preparation of anticancer agents using CSTDs was examined. Visible insoluble fine particles were found in 465 (9.4%) of 4948 treatment cases at Ehime University Hospital with CSTD use. Contaminants occurred more frequently during preparation of monoclonal antibodies than cytotoxic anticancer agents (19.4% vs. 4.1%, respectively, P < 0.01). A similar survey was conducted at nine hospitals to investigate the incidence of insoluble fine particles with or without CSTDs. Insoluble fine particles were detected in 113 (15.4%) of 732 treatment cases during preparation of monoclonal antibodies with CSTD use. In contrast, the occurrence of insoluble fine particles without CSTDs was found in only 3 (0.073%) of 4113 treatment cases. Contamination with CSTDs might cause harmful effects on patients during cancer therapy. We strongly recommend the use of in-line filters combined with infusion routes after CSTD use to avoid contamination-associated adverse events.

2021 ◽  
Author(s):  
Satomi Sumikawa ◽  
Yoshihiro Yakushijin ◽  
Kenjiro Aogi ◽  
Takuya Yano ◽  
Hiroki Hashimoto ◽  
...  

Abstract Occupational exposure of anticancer agents during their preparation has been recognized as a serious hazard. Closed system drug transfer devices (CSTDs) enable “safe” preparation of agents for medical personnel and ensure a safe hospital environment. However, artificial particles of infusion materials have been reported during CSTD use. Here, the incidence of insoluble fine particles during preparation of anticancer agents using CSTDs was examined. Visible insoluble fine particles were found in 465 (9.4%) of 4,948 treatment cases at Ehime University Hospital with CSTD use. Contaminants occurred more frequently during preparation of monoclonal antibodies than cytotoxic anticancer agents (19.4% versus 4.1%, respectively, P<0.01). A similar survey was conducted at nine hospitals to investigate the incidence of insoluble fine particles with or without CSTDs. Insoluble fine particles were detected in 113 (15.4%) of 732 treatment cases during preparation of monoclonal antibodies with CSTD use. In contrast, the occurrence of insoluble fine particles without CSTDs was found in only 3 (0.073%) of 4,113 treatment cases. Contamination with CSTDs might cause harmful effects on patients 4 during cancer therapy. We strongly recommend the use of in-line filters combined with infusion routes after CSTD use to avoid contamination-associated adverse events.


2020 ◽  
Vol 9 (11) ◽  
pp. 3472 ◽  
Author(s):  
Elena-Mihaela Cordeanu ◽  
Lucas Jambert ◽  
Francois Severac ◽  
Hélène Lambach ◽  
Jonathan Tousch ◽  
...  

(1) Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) penetrates respiratory epithelium through angiotensin-converting enzyme-2 binding, raising concerns about the potentially harmful effects of renin–angiotensin system inhibitors (RASi) on Human Coronavirus Disease 2019 (COVID-19) evolution. This study aimed to provide insight into the impact of RASi on SARS-CoV-2 outcomes in patients hospitalized for COVID-19. (2) Methods: This was a retrospective analysis of hospitalized adult patients with SARS-CoV-2 infection admitted to a university hospital in France. The observation period ended at hospital discharge. (3) Results: During the study period, 943 COVID-19 patients were admitted to our institution, of whom 772 were included in this analysis. Among them, 431 (55.8%) had previously known hypertension. The median age was 68 (56–79) years. Overall, 220 (28.5%) patients were placed under mechanical ventilation and 173 (22.4%) died. According to previous exposure to RASi, we defined two groups, namely, “RASi” (n = 282) and “RASi-free” (n = 490). Severe pneumonia (defined as leading to death and/or requiring intubation, high-flow nasal oxygen, noninvasive ventilation, and/or oxygen flow at a rate of ≥5 L/min) and death occurred more frequently in RASi-treated patients (64% versus 53% and 29% versus 19%, respectively). However, in a propensity score-matched cohort derived from the overall population, neither death (hazard ratio (HR) 0.93 (95% confidence interval (CI) 0.57–1.50), p = 0.76) nor severe pneumonia (HR 1.03 (95%CI 0.73–1.44), p = 0.85) were associated with RASi therapy. (4) Conclusion: Our study showed no correlation between previous RASi treatment and death or severe COVID-19 pneumonia after adjustment for confounders.


2021 ◽  
pp. 107815522110306
Author(s):  
Galit Levin ◽  
Paul JM Sessink

Purpose The purpose of this study was to test the efficacy of ChemfortTM, an air filtration closed-system drug transfer device to prevent release of chemotherapy drug vapors and aerosols under extreme conditions. The air cleaning system is based on the adsorption of drug vapors by an activated carbon filter in the Vial Adaptor before the air is released out of the drug vial. The functionality of the carbon filter was also tested at the end of device’s shelf life, and after a contact period with drug vapors for 7 days. Cyclophosphamide and 5-fluorouracil were the chemotherapy drugs tested. Methods The Vial Adaptor was attached to a drug vial and both were placed in a glass vessel. A needle was punctured through the vessel stopper and the Vial Adaptor septum to allow nitrogen gas to flow into the vial and to exit the vial via the air filter into the glass vessel which was connected to a cold trap. Potential contaminated surfaces in the trap system were wiped or rinsed to collect the escaped drug. Samples were analyzed using liquid chromatography tandem mass spectrometry. Results Cyclophosphamide and 5-fluorouracil were detected on most surfaces inside the trap system for all Vial Adaptors without an activated carbon filter. Contamination did not differ between the Vial Adaptors with and without membrane filter indicating no effect of the membrane filter. The results show no release of either drug for the Vial Adaptors with an activated carbon filter even after 3 years of simulated aging and 7 days of exposure to drug vapors. Conclusions Validation of air cleaning CSTDs is important to secure vapor and aerosol containment of chemotherapy and other hazardous drugs. The presented test method has proven to be appropriate for the validation of ChemfortTM Vial Adaptors. No release of cyclophosphamide and 5- fluorouracil was found even for Vial Adaptors after 3 years of simulated aging and 7 days of exposure to drug vapors.


Author(s):  
Seon-Ju Kam ◽  
Young-Sun Yoo

Patients’ emotional responses to the hospital environment can be considered as important as medical technology and equipment. Therefore, this study investigated their experiences to determine whether the pattern using hospital identity (HI) elements, a widely used design method for patient clothing in university hospitals, can affect their emotional response and contribute to healing. It aimed to identify whether controlling the motif characteristics, arrangement, and spacing in this pattern design, and the direction between motifs, could be a method to design patient clothing for healing. To investigate patients’ emotional response and suggestions for patient clothing design, an interview-based qualitative approach was used. In-depth interviews were conducted with 12 patients discharged from Kyung Hee University Hospital Medical Center (KHUMC), Seoul. The interview questions consisted of two parts. One part featured questions about participants’ emotional responses to the medical environment and their latest patient clothing experience, and the other featured questions about their emotional response to, and suggestions for, the healing expression of pattern design using HI. The results confirmed that the motif characteristics, arrangement, and spacing, and the direction between motifs, influenced patients’ positive emotions and contributed to the healing effect. Therefore, when the HI elements of a medical institution are applied in the design of patient clothing with the characteristics of a healing design, patients perceive this as providing stability and comfort. The design of patient clothing becomes a medium that not only builds the brand image of medical institutions, but also enhances the quality of medical services centered on patient healing.


2009 ◽  
Vol 58 (2) ◽  
pp. 228-233 ◽  
Author(s):  
Magdalena Strus ◽  
Dorota Pawlik ◽  
Monika Brzychczy-Włoch ◽  
Tomasz Gosiewski ◽  
Krzysztof Rytlewski ◽  
...  

The study was arranged to assess the actual rates of colonization of pregnant women and their children with group B streptococcus (GBS) in a Polish university hospital. Resistance of these cocci to macrolides and clindamycin was also tested and routes of transmission of GBS were followed in some cases using molecular typing. Colonization with GBS was checked in 340 pregnant women living in the south-eastern region of Poland (Małopolska) in the years 2004–2006. Women with a complicated pregnancy were more often colonized than those with a normal pregnancy (20.0 % versus 17.2 %). Moreover, women with a complicated pregnancy were twice as often colonized with GBS strains with the MLSB phenotype indicating resistance to macrolides and clindamycin. Regarding neonatal colonization by GBS, we found that neonates born from the colonized mothers with a complicated pregnancy were more often colonized with GBS than those from the mothers with a normal pregnancy (35 % versus 26.7 %). By molecular typing of the GBS strains isolated from mothers and their newborns we have been able to suggest the possibility of horizontal transmission of the strains from the hospital environment to newborns. Our results clearly indicate that rates of GBS colonization among pregnant women and neonates in a Polish university hospital have reached levels comparable to those reported in other European clinical centres.


2021 ◽  
Vol 141 (1) ◽  
pp. 143-150
Author(s):  
Hiromasa Ishimaru ◽  
Yasumasa Tsuda ◽  
Hidenori Kage ◽  
Tomoaki Kawano ◽  
Shinji Takayama ◽  
...  

2011 ◽  
Vol 60 (2) ◽  
pp. 155-161 ◽  
Author(s):  
GRAŻYNA SZYMAŃSKA ◽  
MAGDALENA SZEMRAJ ◽  
ELIGIA M. SZEWCZYK

The activity of beta-lactam antibiotics (oxacillin, cloxacillin, cephalotin), vancomycin, gentamicin and rifampicin applied in vitro individually and in combination against 37 nosocomial methicillin-resistant strains of coagulase-negative staphylococci (CNS) was assessed to demonstrate the heterogeneity of this group of bacteria and estimate the chance of the efficacy of such therapy. The strains belonged to four species: Staphylococcus epidermidis, Staphylococcus haemolyticus, Staphylococcus cohnii, Staphylococcus hominis. They originated from a hospital environment and from the skin of medical staff of the intensive care unit of a paediatric ward at a university hospital. All strains were methicillin-resistant, according to CLSI standards, but individual strains differed in MIC(ox) values. Susceptibility to other tested antibiotics was also characteristic for the species. The increased susceptibility to antibiotics in combinations, tested by calculating the fractional inhibitory concentration (FIC) index, concerned 26 out of 37 investigated strains and it was a feature of a particular species. Combinations of vancomycin and cephalotin against S. epidermidis and oxacillin with vancomycin were significant, as well as cephalotin and rifampicin in growth inhibition of multiresistant S. haemolyticus strains.


Sign in / Sign up

Export Citation Format

Share Document