scholarly journals Evaluating the interchangeability of infrared and digital devices with the traditional mercury thermometer in hospitalized pediatric patients: an observational study

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Angelo Dante ◽  
Elona Gaxhja ◽  
Vittorio Masotta ◽  
Carmen La Cerra ◽  
Valeria Caponnetto ◽  
...  

AbstractGradual replacement of the mercury thermometers with alternative devices is ongoing around the world in a bid to protect human health and the environment from the adverse effects of mercury. However, to reduce the risks of misdiagnosis, unnecessary treatments, and omission of care in pediatric populations, more evidence on the reliability of alternative thermometers is needed. The aim of this comparative observational study was to detect any differences in temperature measurements between the use of the axillary mercury thermometer and the alternative techniques. Temperature values in degree Celsius (°C) were measured in a group of Albanian children aged up to 14 years using mercury and digital axillary thermometers, as well as forehead and tympanic infrared thermometers. The digital axillary device, compared with the mercury one, showed no clinically significant difference in the mean values (− 0.04 ± 0.29 °C) and the narrowest 95% level of agreement (+ 0.53 °C to − 0.62 °C) in the paired comparisons. For cut-off point of 37.5 °C, the digital axillary thermometer showed the highest levels of sensitivity (72.5%) and specificity (99.1%) in detecting fever. This study indicates that the digital axillary thermometer may be the better option since it adequately balances accuracy, safety, and children’s comfort.

2020 ◽  
Author(s):  
Angelo Dante ◽  
Elona Gaxhja ◽  
Vittorio Masotta ◽  
Carmen La Cerra ◽  
Valeria Caponnetto ◽  
...  

Abstract A gradual replacement of the mercury thermometers with alternative devices is ongoing around the world as effect of the global strategies to reduce mercury pollution. However, to reduce the risks of misdiagnosis, unnecessary treatments, and omission of care in the pediatric population, more evidence on the reliability and validity of alternative thermometers are needed. The aim of this comparative observational study was to detect any differences in temperature measurements between the gold-standard axillary mercury thermometer (AXLMER) and the alternative devices. Temperature values in Celsius (°C) were simultaneously measured in a group of Albanian children aged up to 14 years using both (AXLMER) and digital axillary thermometers (AXLDGT), as well as forehead and tympanic infra-red thermometers. The AXLDGT device, compared with the AXLMER, showed no clinically significant difference in the mean values (-0.04 ± 0.29 °C) and the narrowest 95% Level of Agreement (+0.53 °C to -0.62 °C) in the paired comparisons. For cut-off points of 37.0 °C and 37.5 °C, the AXLDGT showed the highest levels of sensitivity (67.4% and 72.5%) and specificity (95.3% and 99.1%) in detecting fever. This study indicates that the AXLDGT thermometer may prove the better option since it adequately balances accuracy, safety and children’s comfort.


2020 ◽  
Vol 12 (2) ◽  
pp. 67-75
Author(s):  
Subhramoy Chaudhury ◽  
Anasuya Ghosh

Objectives: Thoracic outlet syndrome (TOS) is an upper extremity disorder resulting from compression of brachial plexus structures and subclavian vessels within thoracic outlet region at any of the three primary sites- interscalene triangle, costoclavicular space and retro-pectoralis minor space. This study focused on detailed anatomic exploration and measurement of normal anatomic variability within interscalene triangle and costoclavicular space. Material and Method:  We examined 49 cadavers (22 male and 27 female) and dissected both sides to explore and examine 98 dissected areas. We measured the base width, height, angle within interscalene triangle and the vertical distance within costoclavicular space. We also calculated the area of interscalene triangle. Results: The mean values of base width, height, interscalene angulation of interscalene triangle and height of costoclavular space was 10.18±4.31 mm, 45.19±0.07mm, 10.85±0.06 degrees and 10.22±0.07 mm respectively. The mean area of interscalene triangle was 214.82±5.22sqmm. Conclusion: We have found clinically significant differences between the interscalene and costiclavicular space vertical heights; the height of costoclavicular space was clinically significantly lower than the interscalene space (p< 0.001). No clinical significant difference was found between male and female measurements. These ranges of dataset could be useful for planning treatment approaches in TOS.


Children ◽  
2022 ◽  
Vol 9 (1) ◽  
pp. 88
Author(s):  
Ana M Calvo-Maroto ◽  
Sara Llorente-González ◽  
Jaione Bezunartea-Bezunartea ◽  
Francisco Javier Hurtado-Ceña ◽  
Clara Berrozpe-Villabona ◽  
...  

The main aim of this study was to compare refraction measurements with and without cycloplegia from two refractors devices, (TRK-2P autorefractometer (TRK-2P) and wavefront-based refraction Visionix 130 (VX130)) in children and adolescents. This descriptive observational study included 20 myopic eyes and 40 hyperopic eyes measured in two different Spanish hospitals. Cycloplegia was carried out by three drops of cyclopentolate hydrochloride 1% (Colircusí cycloplegic, Alcon Healthcare S.A., Barcelona). The mean age of the myopia group was 12.40 ± 3.48 years; for the hyperopia group, the mean age was 7.37 ± 2.47 years. In the myopia group, autorefraction and wavefront-based refraction did not show clinically significant differences in any components between with and without cycloplegia. The hyperopia group showed statistical and clinically significant differences in sphere and SE components between relaxed and non-relaxed states of accommodation, although the cylindrical components were not clinically different. In this study, we considered a value of ≥0.50D as a clinically significant difference in refraction. Therefore, both devices were capable of obtaining accurate refractions without cyclopegia in myopia children, although they did not avoid instrument myopia and accommodation involved in hyperopia children. Moreover, both refractometers could be useful for astigmatism monitoring in children without the need for cycloplegic drops.


1966 ◽  
Vol 53 (2) ◽  
pp. 177-188 ◽  
Author(s):  
P. Lund-Johansen ◽  
T. Thorsen ◽  
K. F. Støa

ABSTRACT A comparison has been made between (A), a relatively simple method for the measurement of aldosterone secretion rate, based on paper chromatography and direct densitometry of the aldosterone spot and (B) a more elaborate isotope derivative method. The mean secretion rate in 9 normal subjects was 112 ± 26 μg per 24 hours (method A) and 135 ± 35 μg per 24 hours (method B). The »secretion rate« in one adrenalectomized subject after the intravenous injection of 250 μg of aldosterone was 230 μg per 24 hours (method A) and 294 μg per 24 hours (method B). There was no significant difference in the mean values, and correlation between the two methods was good (r = 0.80). It is concluded that the densitometric method is suitable for clinical purposes as well as research, being more rapid and less expensive than the isotope derivative method. Method A also measures the urinary excretion of the aldosterone 3-oxo-conjugate, which is of interest in many pathological conditions. The densitometric method is obviously the less sensitive and a prerequisite for its use is an aldosterone secretion of 20—30 μg per 24 hours. Lower values are, however, rare in adults.


2017 ◽  
Vol 13 (1) ◽  
Author(s):  
Izabel Aparecida Soares ◽  
Mauro Sérgio Téo ◽  
Carlise DEBASTIANI ◽  
Suzymeire BARONI ◽  
Vanessa Silva RETUCI

O trabalho teve por objetivo verificar diferenças entre rendimento do concentrado proteico e proteína bruta da folha da mandioca (Manihot esculenta Crantz), obtidos a partir de três variedades comerciais: branca, cascuda e vermelha. As manivas foram plantadas seguindo o delineamento experimental inteiramente casualizado com três repetições. Nas comparações entre as variedades, considerou coletas escalonadas pós-plantio, realizadas aos 12, 14 e 16 meses. O concentrado proteico foi obtido a partir da farinha das folhas inteiras e submetido ao método de termo - coagulação ácido e a proteína bruta pelo método padrão AOAC. Os dados foram submetidos a análise de variância e comparados pelo teste de Tukey - 5% de probabilidade. Os resultados não indicaram diferença significativa entre as médias obtidas para rendimento de concentrado proteico. Para a variável porcentagem de proteína bruta a variedade Branca foi a que apresentou maior valor, com média de 46,25%, seguida pela Cascuda e Vermelha, 44,52% e 37,30%, sucessivamente. Conclui-se que outros estudos devem avaliar condições que possam influenciar no teor de proteína foliar, como clima e solo, e, avaliar os níveis de ácido cianídrico de cada variedade, indicando qual das três é a melhor para a extração do concentrado proteico das folhas. Palavras chaves: Manihot esculenta Crantz, variedades comerciais, concentrado proteico, proteína bruta. ABSTRACT: The study aimed to assess the differences between income protein concentrate, crude protein of cassava leaf (Manihot esculenta Crantz), obtained from three commercial varieties: white, red and cascuda. The cuttings were planted following the completely randomized design with three replications. Comparisons between the varieties considered after planting staggered collections, held on 12, 14 and 16 months. The protein concentrate was obtained from flour of whole sheets and subjected to the term method - acid coagulation and crude protein by AOAC standard method. The data were submitted to ANOVA and Tukey test - 5% probability. The results indicated no significant difference between the mean values obtained for protein concentrate income. For the variable percentage of crude protein White variety showed the highest, with an average of 46.25%, followed by cascuda and Red, 44.52% and 37.30%, successively. We conclude that further studies should evaluate conditions that may affect the leaf protein content, such as climate and soil, and evaluate the hydrocyanic acid levels of each variety, indicating which of the three is the best for the extraction of protein concentrate from leaves Key words: Manihot esculenta Crantz, commercial varieties, protein concentrate, crude protein.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1078.1-1079
Author(s):  
I. Yoshii

Background:Patient’s global assessment (PGA) is one important component of Boolean composite criteria for remission in treat with rheumatoid arthritis (RA). However, PGA no more than 10mm is sometimes obstacle to attain clinical remission. In recent few years, one opinion that PGA no more than 20mm may be comparable as no more than 10mm.Objectives:The aim of this study is to analyze how difference of these PGA level affect disease activity and daily activities in living, and evaluate which is optimal for the remission with Boolean remission criteria from real world setting.Methods:RA patients who were followed up for more than three years in the institute were picked up in the study. Each patient was monitored with tenderness joint count (TJC), swollen joint count (SJC), PGA, evaluator’s global assessment (EGA), serum C-reactive protein level (CRP), calculated disease activity score with simplified disease activity index(SDAI), Health Assessment Questionnaire Disability Index (HAQ-DI), and pain score using visual analog scale (PS-VAS) every consulted time from the first encounter (Baseline). Patients were classified according to achievement of Boolean remission criteria. Group 1: a patient group who attained Boolean remission wih TJC≦1, SJC≦1, CRP≦1mg/dl, and PGA≦1 (G-1), Group 2: a patient group who could not attained the Boolean remission used in the G-1 evaluation, but could attained another Boolean remission with TJC≦1, SJC≦1, CRP≦1mg/dl, and PGA≦2 (G-2), and Group 3: a patient group who could not attain Boolean remission for neither criterion.Mean values of measured parameters at Baseline and after the Baseline were compared statistically with Student T-test. Mean values of the same parameters in the G-1 and G-2 at the time of attain Boolean remission for each criteria, mean values of each of these parameters thereafter, and changes of these parameters were compared statistically with Student T-test.Results:A total of 438 patients 385 in the G-1 group, 16 in the G-2 group, and 37 in the G-3 group, were recruited. In parameters at Baseline, level of TJC, SJC, PGA, EGA, SDAI, and HAQ-DI in the G-1 was significantly lower than in the G-3, whereas no significant differences in any parameters demonstrated between in the G-2 and G-3. Level of HAQ-DI, and PS-VAS after Baseline in the G-1 was lower than in the G-3, whereas no significant difference of these parameters after Baseline demonstrated between in the G-2 and G-3. TJC, SJC, PGA, and EGA demonstrated significant less level in the G-1 than in the other two groups. The mean SDAI score at the time of first achievement of Boolean remission in the G-1 and G-2 were 1.08 and 2.57, respectively. The mean value of SDAI score after remission in the G-1 and G-2 were 3.35 and 6.44, respectively. These values and PS-VAS including change of the SDAI score demonstrated significant difference between the two groups (p<0.01), whereas HAQ-DI in the two groups demonstrated no significant difference.Conclusion:These results suggested that setting PGA as no more than 10mm should be reasonable for the evaluation of clinical remission with the Boolean criteria.Disclosure of Interests:None declared


Author(s):  
Yuko Komuro ◽  
Yuji Ohta

Conventionally, the strength of toe plantar flexion (STPF) is measured in a seated position, in which not only the target toe joints but also the knee and particularly ankle joints, are usually restrained. We have developed an approach for the measurement of STPF which does not involve restraint and considers the interactions of adjacent joints of the lower extremities. This study aimed to evaluate this new approach and comparing with the seated approach. A thin, light-weight, rigid plate was attached to the sole of the foot in order to immobilize the toe area. Participants were 13 healthy young women (mean age: 24 ± 4 years). For measurement of STPF with the new approach, participants were instructed to stand, raise the device-wearing leg slightly, plantar flex the ankle, and push the sensor sheet with the toes to exert STPF. The sensor sheet of the F-scan II system was inserted between the foot sole and the plate. For measurement with the seated approach, participants were instructed to sit and push the sensor with the toes. They were required to maintain the hip, knee, and ankle joints at 90°. The mean values of maximum STPF of the 13 participants obtained with each approach were compared. There was no significant difference in mean value of maximum STPF when the two approaches were compared (new: 59 ± 23 N, seated: 47 ± 33 N). The coefficient of variation of maximum STPF was smaller for data obtained with the new approach (new: 39%, seated: 70%). Our simple approach enables measurement of STPF without the need for the restraints that are required for the conventional seated approach. These results suggest that the new approach is a valid method for measurement of STPF.


2001 ◽  
Vol 92 (1) ◽  
pp. 234-250 ◽  
Author(s):  
Kenichi Kaneko ◽  
Kazuyoshi Sakamoto

Visual fatigue caused by prolonged work viewing a Visual Display Terminals (VDT) and of work reading a hard-copy were assessed by electromyogram (EMG) waveform and electrooculogram (EOG) waveform in spontaneous blinks as objective criteria, and by questionnaire of subjective feeling, and by task performance. The duration and the amplitude of the EMG of the orbicularis ocular muscle on the right side and the EOG of the vertical direction to the eyelid were measured for 10 subjects who participated in a figure task consisting of the addition of single-digit numbers on a VDT work or a work with a hard-copy. The mean values of the duration and the amplitude of the EMG and the EOG were evaluated by the averaging of 10 waveforms of the spontaneous blinks for all subjects. The time lag from the EMG to the EOG in the process of the generation of spontaneous blinks was also analyzed. These five parameters were evaluated during the work time. The mean values for the duration of the EMG increased gradually during the work time, but the amplitude did not show significant difference between the prework and a work time. There was no significant change of the duration of the EOG, but the mean amplitude of the EOG decreased as the work time progressed, and the time lag significantly extended. The blinks frequency increased relatively when using a VDT. The rate of fluctuation for these parameters was higher during use of a VDT than use of a hard-copy. The time lag at five hours of VDT work was extended by 90% based on the value at the prework. The symptoms of general fatigue and fatigue of the eyes increased linearly during the VDT work for six hours. The results indicated a significant correlation between the objective parameters for the activity of the spontaneous blinks, i.e., duration and amplitude of EMG and EOG, and the time lag between EMG and EOG, and the subjective feeling was recognized in the time course of the task. These experimental results suggested that the parameters regarding the EMG and the EOG for the spontaneous blinks were effective indices for assessing visual fatigue during prolonged VDT work.


2013 ◽  
Vol 24 (5) ◽  
pp. 482-486 ◽  
Author(s):  
Marili Doro Andrade Deonizio ◽  
Gilson Blitzkow Sydney ◽  
Antonio Batista ◽  
Roberto Pontarolo ◽  
Paulo Ricardo Bittencourt Guimarães ◽  
...  

This study evaluated the influence of apical patency, root filling removal technique and cleaning of the apical foramen, concerning the amount of debris extruded during root canal retreatment. Forty mandibular incisors were randomly assigned to 4 groups - GIM (n=10), GIIM (n=10), GIPT (n=10) and GIIPT (n=10), which were named according to leaving (I) or not (II) apical patency during canal preparation and filling removal technique (manual - M or ProTaper system - PT). After filling material removal, each specimen of each group had the apical foramen cleaned by sizes 15, 20 and 25 instruments, generating 12 subgroups: GIM15, GIM20, GIM25, GIIM15, GIIM20, GIIM25, GIPT15, GIPT20, GIPT25, GIIPT15, GIIPT20 and GIIPT25. Extruded filling debris was collected by a Milipore filtration system, an HV-durapore, 0.45 µm pore filter with a 25 mm diameter. The filters were weighed before and after the collection on an analytical scale (10–5 g), and the difference was calculated. The mean weight of extruded filling debris was analyzed statistically by Kruskal-Wallis and Friedman ANOVA tests (α=0.05). The mean values found in the groups (in mg) were: GIM (0.95±0.94), GIIM (0.47±0.62), GIPT (0.30±0.31) and GIIPT (0.32±0.44). There was no statistically significant difference among any of the groups or subgroups (p>0.05). ProTaper provided the smallest amount of extruded filling material, regardless of presence or absence of apical patency, followed by manual technique, without and with apical patency. Additional amounts of debris were collected during cleaning of the apical foramen, regardless of the instrument, presence/absence of patency or root filling removal technique.


2015 ◽  
Vol 11 (S317) ◽  
pp. 352-353
Author(s):  
G. Tautvaišienė ◽  
A. Drazdauskas ◽  
C. Lardo ◽  
S. L. Martell ◽  
E. Pancino ◽  
...  

AbstractWe provide CNO and Fe abundance investigations for a sample of up to 45 NGC 1851 giants. High-resolution spectra were obtained with the VLT UVES spectrograph in the framework of the Gaia-ESO Survey. The stars in our sample can be separated into two groups with a difference of 0.1 dex in the mean metallicity, 0.3 dex in the mean C/N, and no significant difference in the mean values of C+N+O.


Sign in / Sign up

Export Citation Format

Share Document