scholarly journals Free-radical-induced formation of an 8,5′-cyclo-2′-deoxyguanosine moiety in deoxyribonucleic acid

1986 ◽  
Vol 238 (1) ◽  
pp. 247-254 ◽  
Author(s):  
M Dizdaroglu

Isolation and identification of a novel .OH-induced product, namely an 8,5′-cyclo-2′-deoxyguanosine moiety, in DNA and 2′-deoxyguanosine are described. .OH radicals were generated in dilute aqueous solutions by gamma-irradiation. Analyses of 2′-deoxyguanosine and enzymic hydrolysates of DNA by gas chromatography-mass spectrometry (g.c.-m.s.) after trimethylsilylation showed the presence of 8,5-cyclo-2′-deoxyguanosine on the basis of its fragment ions. This product was isolated by h.p.l.c. Its u.v. and n.m.r. spectra taken were in agreement with the structure suggested by its mass spectrum. Exact masses of the typical ions from the mass spectrum of the trimethylsilyl derivative of this product were measured by high-resolution m.s. The values found were in excellent agreement with the theoretical mass derived from the suggested fragmentation patterns. Both (5′R)- and (5′S)-epimers of 8,5′-cyclo-2′-deoxyguanosine were observed. These two diastereomers were separated from each other by g.c. as well as by h.p.l.c. The assignment of the epimers was accomplished on the basis of the n.m.r. data. The formation of 8,5′-cyclo-2′-deoxyguanosine was suppressed by the presence of O2 in the solutions. The use of g.c.-m.s. with the selected-ion monitoring technique facilitated the detection of 8,5′-cyclo-2′-deoxyguanosine in DNA at radiation doses as low as 1 Gy. Its mechanism of formation probably involves hydrogen atom abstraction by .OH radicals from the C-5′ of the 2′-deoxyguanosine moiety followed by intramolecular cyclization with the formation of a covalent bond between the C-5′ and C-8 and subsequent oxidation of the resulting N-7-centred radical.

1994 ◽  
Vol 40 (2) ◽  
pp. 216-220 ◽  
Author(s):  
A H Wu ◽  
D Ostheimer ◽  
M Cremese ◽  
E Forte ◽  
D Hill

Abstract Interference by substances coeluting with targeted drugs is a general problem for gas chromatographic/mass spectrometric analysis of urine. To characterize these interferences, we examined human urine samples containing benzoylecgonine and fluconazole, and other drug combinations including deuterated internal standards that coelute (ISd,c) with target drugs, by selected-ion monitoring (SIM) and full-scan mass spectrometry. We show that, by SIM analysis, detecting the presence of an interferent is dependent on the specific IS used for the assay. When an ISd,c is used, the presence of another coeluting substance (interferent) suggests that the intensity of IS ions is substantially diminished, because the interferent affects both the ISd,c and target drug. When a noncoeluting IS (ISnc) is used, the interferent cannot be discerned unless it coincidently contains one or more of the ions monitored for either the target drug or ISnc. Under full-scan analysis, a coeluting interferent is directly discernable by examining the total ion gas chromatogram.


Molecules ◽  
2021 ◽  
Vol 26 (11) ◽  
pp. 3101
Author(s):  
Mariana N. Oliveira ◽  
Oriana C. Gonçalves ◽  
Samir M. Ahmad ◽  
Jaderson K. Schneider ◽  
Laiza C. Krause ◽  
...  

This work entailed the development, optimization, validation, and application of a novel analytical approach, using the bar adsorptive microextraction technique (BAμE), for the determination of the six most common tricyclic antidepressants (TCAs; amitriptyline, mianserin, trimipramine, imipramine, mirtazapine and dosulepin) in urine matrices. To achieve this goal, we employed, for the first time, new generation microextraction devices coated with convenient sorbent phases, polymers and novel activated carbons prepared from biomaterial waste, in combination with large-volume-injection gas chromatography-mass spectrometry operating in selected-ion monitoring mode (LVI-GC-MS(SIM)). Preliminary assays on sorbent coatings, showed that the polymeric phases present a much more effective performance, as the tested biosorbents exhibited low efficiency for application in microextraction techniques. By using BAμE coated with C18 polymer, under optimized experimental conditions, the detection limits achieved for the six TCAs ranged from 0.2 to 1.6 μg L−1 and, weighted linear regressions resulted in remarkable linearity (r2 > 0.9960) between 10.0 and 1000.0 μg L−1. The developed analytical methodology (BAμE(C18)/LVI-GC-MS(SIM)) provided suitable matrix effects (90.2–112.9%, RSD ≤ 13.9%), high recovery yields (92.3–111.5%, RSD ≤ 12.3%) and a remarkable overall process efficiency (ranging from 84.9% to 124.3%, RSD ≤ 13.9%). The developed and validated methodology was successfully applied for screening the six TCAs in real urine matrices. The proposed analytical methodology proved to be an eco-user-friendly approach to monitor trace levels of TCAs in complex urine matrices and an outstanding analytical alternative in comparison with other microextraction-based techniques.


2012 ◽  
Vol 262 ◽  
pp. 561-566
Author(s):  
Chao Ding ◽  
Fang Wang ◽  
Mei Xia Pang ◽  
Xin Xin Yi ◽  
Feng Tan ◽  
...  

A new method was established for detecting a series of photoinitiators (PIs) in printed cartonboard food-packaging materials, which were benzophenone (BP), 4-methylbenzophenone (MBP), 1-hydroxycyclohexyl phenyl ketone (Irgacure184), ethyl-4-dimethylaminobenzoate (EDAB), 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB) and 2-isopropylthioxanthone (ITX) by gas chromatography–mass spectrometry (GC/MS). Extraction was carried out with ethyl acetate by ultrasonic solvent extraction. Samples were analyzed by GC/MS in selected ion monitoring (SIM) mode. The results indicated that six kinds of PIs had good linear relations (R2>0.9989) in the range of 10~200 μg/L. Limit of Detections (LODs) and Limit of Quantifications ( LOQs ) of all kinds of PIs were 0.3~2.6 μg /kg and 1~8 μg/kg, respectively. The recoveries of six kinds of PIs at three kinds of concentrations researched (0.30 μg/kg, 0.60 μg/ kg, 1.0 μg/kg) were ranging from 66.7%~89.4%, with the Relative Standard Deviation (RSD) of 4.2%~10.6% (n=6). The results also suggested that PIs were detected in food packaging materials.


2017 ◽  
Vol 15 (1) ◽  
pp. 1
Author(s):  
Sari Setianingsih ◽  
Rudi Kartika ◽  
Partomuan Simanjuntak

This study was started by extraction of Eucalyptus deglupta Blume. Using organic solvent   (n-hexane, ethyl acetate, ethanol and water) followed by phytochemical screening and toxicity test using Brine Shrimp Lethality Test (BSLT) method. Isolation and identification of chemical compounds contained in the fraction were done by column chromatography and Gas Chromatography-Mass Spectrometry (GC-MS) analysis. Phytochemical screening revealed the presence of alkaloids, flavonoids, steroids and phenolics in the extract. Toxicity test results showed that the ethyl acetate extract was potentially active with LC50 value of  617.95 ppm. The extract was continued to isolation stage and gave fraction EKEA-3.1 with LC50 value of 2759.93 ppm. Identification of chemical compounds in EKEA-3.1 with KG-MS analysis showed that EKEA-3.1 was suspected to be Stigmastan-3,5-diene.


Sign in / Sign up

Export Citation Format

Share Document