scholarly journals Experimental Evaluation of the Ability of an Auxiliary Heating Device to Reduce the Condensation Risk around Built-in Wardrobes of Apartment Buildings in Winter

2019 ◽  
Vol 111 ◽  
pp. 01014
Author(s):  
Chae Lyn Lee ◽  
Hyun Hwa Lee ◽  
Jae Han Lim ◽  
Seung Yeong Song

Recently, there has been an increase in the condensation and mould problems of apartment buildings in Korea owing to the high insulation and high air-tightness performance of buildings, which increase energy savings. Condensation is generally found in winter on furniture back panels and adjacent surfaces of the wall, floor, and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, an auxiliary heating device that can be installed was developed. The purpose of this study was to evaluate condensation risk in the condensation vulnerable areas around built-in furniture of apartment buildings by installing an auxiliary heating device. The experimental results reveal that condensation risk can be reduced by comparing the thermal environment around the built-in furniture with and without installation of an auxiliary heating device in winter. Furthermore, they reveal that it is possible to increase the surface temperature of vulnerable areas around built-in wardrobe by applying an auxiliary heating device to minimize condensation problems by using a minimum device.

Materials ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1226
Author(s):  
Beatriz Fraga-De Cal ◽  
Antonio Garrido-Marijuan ◽  
Olaia Eguiarte ◽  
Beñat Arregi ◽  
Ander Romero-Amorrortu ◽  
...  

Prefabricated solutions incorporating thermal insulation are increasingly adopted as an energy conservation measure for building renovation. The InnoWEE European project developed three technologies from Construction and Demolition Waste (CDW) materials through a manufacturing process that supports the circular economy strategy of the European Union. Two of them consisted of geopolymer panels incorporated into an External Thermal Insulation Composite System (ETICS) and a ventilated façade. This study evaluates their thermal performance by means of monitoring data from three pilot case studies in Greece, Italy, and Romania, and calibrated building simulation models enabling the reliable prediction of energy savings in different climates and use scenarios. Results showed a reduction in energy demand for all demo buildings, with annual energy savings up to 25% after placing the novel insulation solutions. However, savings are highly dependent on weather conditions since the panels affect cooling and heating loads differently. Finally, a parametric assessment is performed to assess the impact of insulation thickness through an energy performance prediction and a cash flow analysis.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 3143 ◽  
Author(s):  
Ignacio Acosta ◽  
Miguel Ángel Campano ◽  
Samuel Domínguez-Amarillo ◽  
Carmen Muñoz

Daylight performance metrics provide a promising approach for the design and optimization of lighting strategies in buildings and their management. Smart controls for electric lighting can reduce power consumption and promote visual comfort using different control strategies, based on affordable technologies and low building impact. The aim of this research is to assess the energy efficiency of these smart controls by means of dynamic daylight performance metrics, to determine suitable solutions based on the geometry of the architecture and the weather conditions. The analysis considers different room dimensions, with variable window size and two mean surface reflectance values. DaySim 3.1 lighting software provides the simulations for the study, determining the necessary quantification of dynamic metrics to evaluate the usefulness of the proposed smart controls and their impact on energy efficiency. The validation of dynamic metrics is carried out by monitoring a mesh of illuminance-meters in test cells throughout one year. The results showed that, for most rooms more than 3.00 m deep, smart controls achieve worthwhile energy savings and a low payback period, regardless of weather conditions and for worst-case situations. It is also concluded that dimming systems provide a higher net present value and allow the use of smaller window size than other control solutions.


2004 ◽  
Vol 31 (2) ◽  
pp. 369-378 ◽  
Author(s):  
Aly Sherif ◽  
Yasser Hassan

Road and highway maintenance is vital for the safety of citizens and for enabling emergency and security services to perform their essential functions. Accumulation of snow and (or) ice on the pavement surface during the wintertime substantially increases the risk of road crashes and can have negative impact on the economy of the region. Recently, road maintenance engineers have used pavement surface temperature as a guide to the application of deicers. Stations for road weather information systems (RWIS) have been installed across Europe and North America to collect data that can be used to predict weather conditions such as air temperature. Modelling pavement surface temperature as a function of such weather conditions (air temperature, dew point, relative humidity, and wind speed) can provide an additional component that is essential for winter maintenance operations. This paper uses data collected by RWIS stations at the City of Ottawa to device a procedure that maximizes the use of a data batch containing complete, partially complete, and unusable data and to study the relationship between the pavement surface temperature and weather variables. Statistical models were developed, where stepwise regression was first applied to eliminate those variables whose estimated coefficients are not statistically significant. The remaining variables were further examined according to their contribution to the criterion of best fit and their physical relationships to each other to eliminate multicollinearities. The models were further corrected for the autocorrelation in their error structures. The final version of the developed models may then be used as a part of the decision-making process for winter maintenance operations.Key words: winter maintenance, pavement temperature, statistical modelling, RWIS.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


Baltica ◽  
2018 ◽  
Vol 30 (2) ◽  
pp. 75-85 ◽  
Author(s):  
Viktorija Rukšėnienė ◽  
Inga Dailidienė ◽  
Loreta Kelpšaitė-Rimkienė ◽  
Tarmo Soomere

This study focuses on time scales and spatial variations of interrelations between average weather conditions and sea surface temperature (SST), and long-term changes in the SST in south-eastern Baltic Sea. The analysis relies on SST samples measured in situ four times a year in up to 17 open sea monitoring stations in Lithuanian waters in 1960–2015. A joint application of non-metric multi-dimensional scaling and cluster analysis reveals four distinct SST regimes and associated sub-regions in the study area. The increase in SST has occurred during both winter and summer seasons in 1960–2015 whereas the switch from relatively warm summer to colder autumn temperatures has been shifted by 4–6 weeks over this time in all sub-regions. The annual average air temperature and SST have increased by 0.03°C yr–1 and 0.02°C yr–1, respectively, from 1960 till 2015. These data are compared with air temperatures measured in coastal meteorological stations and averaged over time intervals from 1 to 9 weeks. Statistically significant positive correlation exists between the SST and the average air temperature. This correlation is strongest for the averaging interval of 35 days.


2012 ◽  
Vol 253-255 ◽  
pp. 658-669 ◽  
Author(s):  
Serik Tokbolat ◽  
Raikhan Tokpatayeva ◽  
Sarim Al-Zubaidy

There is a distinct lack of building design literature specific to the Central Asian region. This perhaps, could be one of reasons for the only slight improvement of new building designs and construction. One does observe the highly glazed buildings are a particularly popular feature here in Astana, as like anywhere else in the world. However, excessively glazed surfaces combined with the weather extremes leads to adverse internal conditions and skyrocketing energy bills. The work presented in this paper is a part of continuing efforts to identify analyze and promote the design of ‘low energy, green and sustainable buildings with special reference to the Kazakhstan locality. In the present context, low energy buildings’ refers to buildings inherently low energy consuming by careful passive design, utilizing intelligent building technologies to automate building services and minimize wastage of energy and by incorporation of renewable technologies for its energy supply. Demonstration of improved environmental conditions and impact on energy savings will be outlined through a cause study incorporating application of passive design approach and detailed computational fluid dynamics (CFD) analysis for an existing building complex. The results indicated that there is a considerable influence of passive design and orientation on energy efficiency, wind comfort and safety.


2021 ◽  
pp. 1420326X2110345
Author(s):  
Marika Vellei ◽  
William O’Brien ◽  
Simon Martinez ◽  
Jérôme Le Dréau

Recent research suggests that a time-varying indoor thermal environment can lead to energy savings and contribute to boost buildings' energy flexibility. However, thermal comfort standardization has so far considered thermal comfort criteria as constant throughout the day. In general, very little attention has been given to the ‘ time of day' variable in the context of thermal comfort research. In this paper, we show some evidence of a time-varying thermal perception by using: (1) data from about 10,000 connected Canadian thermostats made available as part of the ‘ Donate Your Data' dataset and (2) about 22,000 samples of complete (objective + ‘ right-here-right-now' subjective) thermal comfort field data from the ASHRAE I and SCATs datasets. We observe that occupants prefer colder thermal conditions at 14:00 and progressively warmer ones in the rest of the day, indistinctively in the morning and evening. Neutral temperature differences between 08:00 and 14:00 and 14:00 and 20:00 are estimated to be of the order of 2°C. We hypothesize that the human circadian rhythm is the cause of this difference. Nevertheless, the results of this study are only based on observational data. Thermal comfort experiments in controlled environmental chambers are required to confirm these findings and to better elucidate the effects of light and circadian timing and their interaction on thermal perception.


2021 ◽  
pp. 1-13
Author(s):  
Omer Ahmed Qureshi ◽  
Peter R. Armstrong

Abstract Efficient plant operation can be achieved by properly loading and sequencing available chillers to charge and discharge a thermal energy storage (TES) reservoir at optimal rates and times. TES charging sequences are often determined by heuristic rules that typically aim to reduce utility costs under time of use rates. However, such rules of thumb may result in significantly sub optimal performance on somedays. Rigorous optimization, on the other hand, is computationally expensive and can be unreliable as well if not carefully implemented. Receding Horizon Control (RHC) using the novel finite search algorithm is reliable and can reach ~80% of achievable energy efficiency and/or peak shifting capacity has been our target. A novel algorithm is developed to reliably achieve near optimal control for charging the stratified sensible cool storage reservoir of a chiller plant. The algorithm provides a constant COP (or cost per ton-hour) for 24-hr dispatch plan under which chillers operate during most favorable weather conditions. Analysis of four hot climates, ranging from humid to dry, indicates 2.4~2.6% energy savings under a flat electricity rate relative to the same plant operating without TES. Annual cost savings from 6% to 9% was found for electricity billed under a simple (10am-10pm) time-of-use rate with no demand charge and no ratchet component.