Some evidence of a time-varying thermal perception

2021 ◽  
pp. 1420326X2110345
Author(s):  
Marika Vellei ◽  
William O’Brien ◽  
Simon Martinez ◽  
Jérôme Le Dréau

Recent research suggests that a time-varying indoor thermal environment can lead to energy savings and contribute to boost buildings' energy flexibility. However, thermal comfort standardization has so far considered thermal comfort criteria as constant throughout the day. In general, very little attention has been given to the ‘ time of day' variable in the context of thermal comfort research. In this paper, we show some evidence of a time-varying thermal perception by using: (1) data from about 10,000 connected Canadian thermostats made available as part of the ‘ Donate Your Data' dataset and (2) about 22,000 samples of complete (objective + ‘ right-here-right-now' subjective) thermal comfort field data from the ASHRAE I and SCATs datasets. We observe that occupants prefer colder thermal conditions at 14:00 and progressively warmer ones in the rest of the day, indistinctively in the morning and evening. Neutral temperature differences between 08:00 and 14:00 and 14:00 and 20:00 are estimated to be of the order of 2°C. We hypothesize that the human circadian rhythm is the cause of this difference. Nevertheless, the results of this study are only based on observational data. Thermal comfort experiments in controlled environmental chambers are required to confirm these findings and to better elucidate the effects of light and circadian timing and their interaction on thermal perception.

2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2018 ◽  
Vol 22 (Suppl. 3) ◽  
pp. 785-795 ◽  
Author(s):  
Nikolina Pivac ◽  
Sandro Nizetic ◽  
Vlasta Zanki

An experimental field study has been conducted for typical educational research building facility (office building). The research data was gathered by the systematic monitoring of the offices and adaptive occupant behavior during the typical working day in the spring period. Different sensors and data loggers for temperature, relative humidity, CO2 concentration, had been mounted in order to collect data for analysis of thermal comfort conditions. Moreover, occupant surveys and interviews in form of questionnaire were also brought to examine the psychological and social impacts of the occupants? behavior regarding energy consumption. The inductive scientific method is used for data processing, i. e. descriptive and inferential statistical analysis of the results was made. Based on the analysis of the conducted study, it was found that thermal environment of the observed building is within the standards (i. e. specific parameters are within the range) and that the occupants are generally satisfied with thermal conditions in their offices. However, they do not pay much attention to conserving energy which is an important finding as it is directly related to the energy consumption. Thus, more attention should be directed to the education of the users and in general, to enable energy savings in the future.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2013 ◽  
Vol 2013 ◽  
pp. 1-8 ◽  
Author(s):  
Chuang-Hung Lin ◽  
Tzu-Ping Lin ◽  
Ruey-Lung Hwang

The paper is an effort toward thermal comfort assessment for urban parks under the climatic conditions of Taiwan to help architects achieve better climatic design. Field interviews, observations, and micrometeorological measurements were conducted in this study. The WBGT was used as the thermophysiological index to investigate the effects of thermal conditions on visitor’s thermal perception and adaptive behavior in outdoor urban spaces. In this study, behavioral adaptations used by visitors as a means of achieving comfort were evaluated. Observational results showed that the overall attendance was influenced by sun and thermal conditions. There was a robust relationship between thermal sensation votes, as well as thermal acceptability, and thermal environment, in terms of WBGT. The upper and lower limits of 80% acceptability are 26°C WBGT and 20°C WBGT, respectively.


2021 ◽  
Vol 13 (7) ◽  
pp. 3614
Author(s):  
Zeyad Amin Al-Absi ◽  
Mohd Isa Mohd Hafizal ◽  
Mazran Ismail ◽  
Azhar Ghazali

Building sector is associated with high energy consumption and greenhouse gas emissions, which contribute to climate change. Sustainable development emphasizes any actions to reduce climate change and its effect. In Malaysia, half of the energy utilized in buildings goes towards building cooling. Thermal comfort studies and adaptive thermal comfort models reflect the high comfort temperatures for Malaysians in naturally conditioned buildings, which make it possible to tackle the difference between buildings’ indoor temperature and the required comfort temperature by using proper passive measures. This study investigates the effectiveness of building’s retrofitting with phase change materials (PCMs) as a passive cooling technology to improve the indoor thermal environment for more comfortable conditions. PCM sheets were numerically investigated below the internal finishing of the walls. The investigation involved an optimization study for the PCMs transition temperatures and quantities. The results showed significant improvement in the indoor thermal environment, especially when using lower transition temperatures and higher quantities of PCMs. Therefore, the monthly thermal discomfort time has decreased completely, while the thermal comfort time has increased to as high as 98%. The PCM was effective year-round and the optimum performance for the investigated conditions was achieved when using 18mm layer of PCM27-26.


2020 ◽  
pp. 014459872096921
Author(s):  
Yanru Li ◽  
Enshen Long ◽  
Lili Zhang ◽  
Xiangyu Dong ◽  
Suo Wang

In the Yangtze River zone of China, the heating operation in buildings is mainly part-time and part-space, which could affect the indoor thermal comfort while making the thermal process of building envelope different. This paper proposed to integrate phase change material (PCM) to building walls to increase the indoor thermal comfort and attenuate the temperature fluctuations during intermittent heating. The aim of this study is to investigate the influence of this kind of composite phase change wall (composite-PCW) on the indoor thermal environment and energy consumption of intermittent heating, and further develop an optimization strategy of intermittent heating operation by using EnergyPlus simulation. Results show that the indoor air temperature of the building with the composite-PCW was 2–3°C higher than the building with the reference wall (normal foamed concrete wall) during the heating-off process. Moreover, the indoor air temperature was higher than 18°C and the mean radiation temperature was above 20°C in the first 1 h after stopping heating. Under the optimized operation condition of turning off the heating device 1 h in advance, the heat release process of the composite-PCW to the indoor environment could maintain the indoor thermal environment within the comfortable range effectively. The composite-PCW could decrease 4.74% of the yearly heating energy consumption compared with the reference wall. The optimization described can provide useful information and guidance for the energy saving of intermittently heated buildings.


2019 ◽  
Vol 41 (5) ◽  
pp. 561-585 ◽  
Author(s):  
Fangliang Zhong ◽  
John K Calautit ◽  
Ben R Hughes

After winning the bid of the FIFA’s World Cup 2022, Qatar is facing the greatest challenges in terms of minimizing substantial energy consumptions for air-conditioning of stadiums and maintaining aero-thermal comfort for both players and spectators inside stadiums. This paper presents the results of temperature distributions and wind environment of the original stadium under the hot-humid climate and improvements on them for optimized scenarios of cooling jets. A combined computational fluid dynamics and building energy simulation approach was used to analyse the cooling performance and energy consumption per match of cooling air jets for 10 scenarios with different supply velocities, supply temperatures and locations of jets. The optimal scenario is to employ vertical jets above the upper tiers at supply temperature of 20°C and velocities of 2–12 m/s, integrated with horizontal jets of the same temperature at the lower tiers with 4 m/s and around the pitch with 7 m/s. This scenario can maintain the spectator tiers at an average temperature of 22°C and reduce the maximum predicted percentage of dissatisfied of thermal comfort from the original 100% to 63% for the pitch and 19% for the tiers, respectively. In terms of the energy consumption for the air-conditioning system per match, compared with one of the 2010 South Africa World Cup stadiums Royal Bafokeng stadium which consumed approximately 22.8 MWh energy for air-conditioning in winter (highest outdoor temperature 24.4°C), the maximum energy consumption of the optimal scenario in November (highest outdoor temperature 34.2°C) can reach 108 MWh. In addition, the spectator zones with scenario 8 have the potential to be resilient to the seasonal change of outdoor temperature if slight modifications of the supply velocities and precise temperature control on the spectator zones are applied. Moreover, the configurations presented in this paper can be used as a foundation of jets arrangement for future stadium retrofits in the hot climates. Practical application: This study assesses the aero-thermal conditions of a case study stadium under the hot climate of Qatar and explores the potential of applying cooling jets with different supply velocities, supply temperatures and their locations on the enhancement of both thermal and wind environment of spectator tiers and pitch. The assessment of the original stadium indicates that the ascending curved roof structure impedes the fresh air entering into the stadium and results in an asymmetric temperature distribution on the spectator tiers. The optimized design suggests a combination of vertical jets under the roof and both three arrays of horizontal jets at lower tiers and around pitch for future stadium optimizations in hot climates. It also recommends enhancing the thermal conditions on the pitch by optimizing the velocity of horizontal jets around the pitch. Moreover, the future design of the exact stadiums to be resilient to the seasonal changing outdoor temperature can be implemented based on scenario 8.


2020 ◽  
Vol 15 (3) ◽  
pp. 163-170
Author(s):  
Rajan KC ◽  
Hom Bahadur Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

The energy use in residential dwellings has been increasing due to increasing use of modern electric appliances to make the lifestyle easier, entertaining and better. One of the major purposes of indoor energy use is for improving indoor thermal environment for adjusting thermal comfort. Along with the use of passive means like the use of mechanical devices, the occupants in any dwellings use active means such as the use of natural ventilation, window opening, and clothing adjustment. In fact, the use of active means when the outdoor environment is good enough might be more suitable to improve indoor thermal environment than the use of mechanical air conditioning units, which necessarily require electricity. Therefore, the people in developing countries like Nepal need to understand to what extent the occupants can use active means to manage their own indoor thermal comfort. The use of active means during good outdoor environment might be an effective way to manage increasing energy demand in the future. We have made a field survey on the occupants’ adaptive behaviors for thermal comfort in a Japanese condominium equipped with Home Energy Management System (HEMS). Online questionnaire survey was conducted in a condominium with 356 families from November 2015 to October 2016 to understand the occupants’ behaviors. The number of 17036 votes from 39 families was collected. The indoor air temperature, relative humidity and illuminance were measured at the interval of 2-10 minutes to know indoor thermal environmental conditions. The occupants were found using different active behaviors for thermal comfort adjustments even in rather harsh summer and winter. Around 80% of the occupants surveyed opened windows when the outdoor air temperature was 30⁰C in free running (FR) mode and the clothing insulation was 0.93 clo when the outdoor air temperature was 0⁰C. The result showed that the use of mechanical heating and cooling was not necessarily the first priority to improve indoor thermal environment. Our result along with other results in residential buildings showed that the adaptive behaviors of the occupants are one of the primary ways to adjust indoor thermal comfort. This fact is important in enhancing the energy saving building design.


2020 ◽  
Vol 12 (16) ◽  
pp. 6637
Author(s):  
Jiayu Li ◽  
Bohong Zheng ◽  
Xiao Chen ◽  
Yihua Zhou ◽  
Jifa Rao ◽  
...  

As the window-to-wall ratio, a microclimatic factor in residential districts, regulates the indoor thermal environment and implicates the energy consumption, this research was aimed at interpreting the microclimate effects of the window-to-wall ratio on the indoor thermal environment of the non-Hvac building located in the block from the view of a full year. Urban built parameters and building material parameters applied in Chenzhou were investigated, with the ENVI-met model serving as the analytical tool calculating the meteorological data recorded in the local national meteorological station. The thermal perception criterion of Chenzhou citizens was investigated, and thermal isotherms were employed to interpret the thermal perception distribution throughout the year. Analytical results revealed that the annual indoor thermal environment would deteriorate along with the growth of the window-to-wall ratio in Chenzhou, with the very hot thermal perception environment covering the months from March to October once the window-to-wall ratio outnumbered 60.00%. Furthermore, the hot and very hot thermal perception environments originated in the ranges of 0.00% to 20.00% and that of 20.00% to 40.00%, respectively. Furthermore, if the window-to-wall ratios (WWRs) outnumbered 40%, their effects on the indoor thermal perception environment would gradually decrease and be powerless once that exceeded 80%.


2019 ◽  
Vol 887 ◽  
pp. 428-434
Author(s):  
Dorcas A. Ayeni ◽  
Olaniyi O. Aluko ◽  
Morisade O. Adegbie

Man requires a thermal environment that is within the range of his adaptive capacity and if this fluctuates outside the normal, a reaction is required beyond its adaptive capacity which results to health challenges. Therefore, the aim of building design in the tropical region is to minimize the heat gain indoors and enhance evaporative cooling of the occupants of the space so as to achieve thermal comfort. In most cases, the passive technologies are not adequate in moderating indoor climate for human comfort thereby relying on active energy technique to provide the needed comfort for the building users. The need for the use of vegetation as a panacea for achieving comfortable indoor thermal conditions in housing is recognised by architects globally. However, the practice by architects in Nigeria is still at the lower ebb. The thrust of this paper therefore is to examine the impact of vegetation in solar control reducing thermal discomfort in housing thereby enhancing the energy performance of the buildings. Using secondary data, the paper identifies the benefits of vegetation in and around buildings to include improvement of indoor air quality through the aesthetics quality of the environment and concludes that vegetation in and around building will in no small measure contributes to saving energy consumption.