scholarly journals Manipulation of the swirling flow instability in hydraulic turbine diffuser by different methods of water injection

2018 ◽  
Vol 180 ◽  
pp. 02090 ◽  
Author(s):  
Pavel Rudolf ◽  
Jiří Litera ◽  
Germán Alejandro Ibarra Bolanos ◽  
David Štefan

Vortex rope, which induces substantial pressure pulsations, arises in the draft tube (diffuser) of Francis turbine for off-design operating conditions. Present paper focuses on mitigation of those pulsations using active water jet injection control. Several modifications of the original Susan-Resiga’s idea were proposed. All modifications are driven by manipulation of the shear layer region, which is believed to play important role in swirling flow instability. While some of the methods provide results close to the original one, none of them works in such a wide range. Series of numerical experiments support the idea that the necessary condition for vortex rope pulsation mitigation is increasing the fluid momentum along the draft tube axis.

2009 ◽  
Vol 131 (8) ◽  
Author(s):  
Jorge Arpe ◽  
Christophe Nicolet ◽  
François Avellan

The complex three-dimensional unsteady flow developing in the draft tube of a Francis turbine is responsible for pressure fluctuations, which could prevent the whole hydropower plant from operating safely. Indeed, the Francis draft tube is subjected to inlet swirling flow, divergent cross section, and the change of flow direction. As a result, in low discharge off-design operating conditions, a cavitation helical vortex, so-called the vortex rope develops in the draft tube and induces pressure fluctuations in the range of 0.2–0.4 times the runner frequency. This paper presents the extensive unsteady wall pressure measurements performed in the elbow draft tube of a high specific speed Francis turbine scale model at low discharge and at usual plant value of the Thoma cavitation number. The investigation is undertaken for operating conditions corresponding to low discharge, i.e., 0.65–0.85 times the design discharge, which exhibits pressure fluctuations at surprisingly high frequency value, between 2 and 4 times the runner rotation frequency. The pressure fluctuation measurements performed with 104 pressure transducers distributed on the draft tube wall, make apparent in the whole draft tube a fundamental frequency value at 2.5 times the runner frequency. Moreover, the modulations between this frequency with the vortex rope precession frequency are pointed out. The phase shift analysis performed for 2.5 times the runner frequency enables the identification of a pressure wave propagation phenomenon and indicates the location of the corresponding pressure fluctuation excitation source in the elbow; hydroacoustic waves propagate from this source both upstream and downstream the draft tube.


2019 ◽  
Vol 11 (1) ◽  
pp. 168781401882446 ◽  
Author(s):  
Xing Zhou ◽  
He-gao Wu ◽  
Chang-zheng Shi

An improved method for preventing vortex rope formation and alleviating the associated pressure fluctuations in turbine draft tubes is investigated using baffles in the draft tube to hinder the swirling flow emerging from a Francis turbine runner. A strong swirl produces flow instabilities and pressure fluctuations. Partial load operating conditions at the rated water head and three flow rates are taken into consideration. It is demonstrated using a computational fluid dynamics simulation that this method effectively eliminates the vortex rope, particularly when using four baffles. The amplitude of the pressure pulsation in the draft tube modified with four baffles was 0.42 times that in a traditional draft tube. The baffles were found to reduce the tangential velocity of the flow in the draft tube and consequently hinder the development of the fierce swirling flow. This type of decrease is more significant compared to the gradual decay due to viscous effects of the solid wall in a traditional draft tube. The conclusion was verified by the results of experiments conducted using a novel device. The measured increase in turbine efficiency exceeded 3% at the evaluated partial loading point, indicating improved economic performance of the turbine.


Author(s):  
P. Pennacchi ◽  
P. Borghesani ◽  
S. Chatterton ◽  
A. Vania

Design of hydraulic turbines has often to deal with hydraulic instability. It is well-known that Francis and Kaplan types present hydraulic instability in their design power range. Even if modern CFD tools may help to define these dangerous operating conditions and optimize runner design, hydraulic instabilities may fortuitously arise during the turbine life and should be timely detected in order to assure a long-lasting operating life. In a previous paper, the authors have considered the phenomenon of helical vortex rope, which happens at low flow rates when a swirling flow, in the draft tube conical inlet, occupies a large portion of the inlet. In this condition, a strong helical vortex rope appears. The vortex rope causes mechanical effects on the runner, on the whole turbine and on the draft tube, which may eventually produce severe damages on the turbine unit and whose most evident symptoms are vibrations. The authors have already shown that vibration analysis is suitable for detecting vortex rope onset, thanks to an experimental test campaign performed during the commissioning of a 23 MW Kaplan hydraulic turbine unit. In this paper, the authors propose a sophisticated data driven approach to detect vortex rope onset at different power load, based on the analysis of the vibration signals in the order domain and introducing the so-called “residual order spectrogram”, i.e. an order-rotation representation of the vibration signal. Some experimental test runs are presented and the possibility to detect instability onset, especially in real-time, is discussed.


2014 ◽  
Vol 81 (6) ◽  
Author(s):  
Hosein Foroutan ◽  
Savas Yavuzkurt

Numerical simulations and analysis of the vortex rope formation in a simplified draft tube of a model Francis turbine are carried out in this paper, which is the first part of a two-paper series. The emphasis of this part is on the simulation and investigation of flow using different turbulence closure models. Two part-load operating conditions with same head and different flow rates (91% and 70% of the best efficiency point (BEP) flow rate) are considered. Steady and unsteady simulations are carried out for axisymmetric and three-dimensional grid in a simplified axisymmetric geometry, and results are compared with experimental data. It is seen that steady simulations with Reynolds-averaged Navier–Stokes (RANS) models cannot resolve the vortex rope and give identical symmetric results for both the axisymmetric and three-dimensional flow geometries. These RANS simulations underpredict the axial velocity (by at least 14%) and turbulent kinetic energy (by at least 40%) near the center of the draft tube, even quite close to the design condition. Moving farther from the design point, models fail in predicting the correct levels of the axial velocity in the draft tube. Unsteady simulations are performed using unsteady RANS (URANS) and detached eddy simulation (DES) turbulence closure approaches. URANS models cannot capture the self-induced unsteadiness of the vortex rope and give steady solutions while DES model gives sufficient unsteady results. Using the proper unsteady model, i.e., DES, the overall shape of the vortex rope is correctly predicted and the calculated vortex rope frequency differs only 6% from experimental data. It is confirmed that the vortex rope is formed due to the roll-up of the shear layer at the interface between the low-velocity inner region created by the wake of the crown cone and highly swirling outer flow.


2022 ◽  
Vol 2150 (1) ◽  
pp. 012001
Author(s):  
S G Skripkin ◽  
D A Suslov ◽  
I V Litvinov ◽  
E U Gorelikov ◽  
M A Tsoy ◽  
...  

Abstract This article presents a comparative analysis of flow characteristics behind a hydraulic turbine runner in air and water. Swirling flow with a precessing vortex core (PVC) was investigated using a laser Doppler anemometer and pressure pulsation sensors. The experiments were conducted on aerodynamic and hydrodynamic test rigs over a wide range of hydraulic turbine operating conditions. Part-load modes of hydraulic turbine operation were investigated using the Fourier transform of pressure pulsations obtained from acoustic sensors. The features of the swirling flow were shown for the range of operating conditions from deep partl-load to overload.


2011 ◽  
Vol 105-107 ◽  
pp. 52-55
Author(s):  
Si Qing Zhang ◽  
Chang Zhen Li ◽  
Li Xiang Zhang ◽  
Xiao Xu Zhang

The RNG turbulence model is used to carry out the 3D steady turbulent calculation on the runner and draft tube of the Francis turbine. And the prototype of the Francis turbine is HLA351. Under 8 typical operating conditions, numerical simulation on how the runner outlet urge the vortex rope in draft tube are accomplished in this paper, and the calculation models are long blade model and mixed blade model. The results show that the runner outlet of the mixed model can lead the vortex rope location to the downstream relatively, reduce the circumfluence and cushion area and the probability of the second-vortex. What’s more, the flow pattern in mixed model is superior to the long model and that benefits the operation stability and economy of the unit.


2012 ◽  
Vol 10 ◽  
pp. 48-52
Author(s):  
Ruchi Khare ◽  
Vishnu Prasad

Draft tube is an important component of the hydraulic reaction turbine and affects the overall performance of turbine to a large extent. The flow inside the draft tube is complex because of the whirling flow coming out of runner and its diffusion along the draft tube. The kinetic energy coming out of runner is recovered in draft tube and part of recovery meets the losses. In the present work, the computational fluid dynamics (CFD) has been used for flow simulation in complete mixed flow Francis turbine for performance analysis for energy recovery, losses and flow pattern in an elbow draft tube used in Francis turbine at different operating conditions. The overall performance of the turbine at some typical operating regimes is validated with the experimental results and found to be in close comparison.DOI: http://dx.doi.org/10.3126/hn.v10i0.7103 Hydro Nepal Vol.10 January 2012 48-52


Author(s):  
Xianwu Luo ◽  
An Yu ◽  
Bin Ji ◽  
Yulin Wu ◽  
Yoshinobu Tsujimoto

Hydro turbines operating at partial flow conditions usually have vortex ropes in the draft tube that generate large pressure fluctuations. This unsteady flow phenomenon is harmful to the safe operation of hydropower stations. This paper presents numerical simulations of the internal flow in the draft tube of a Francis turbine with particular emphasis on understanding the unsteady characteristics of the vortex rope structure and the underlying mechanisms for the interactions between the air and the vortices. The pressure fluctuations induced by the vortex rope are alleviated by air admission from the main shaft center, with the water-air two phase flow in the entire flow passage of a model turbine simulated based on the homogeneous flow assumption. The results show that aeration with suitable air flow rate can alleviate the pressure fluctuations in the draft tube, and the mechanism improving the flow stability in the draft tube is due to the change of vortex rope structure and distribution by aeration, i.e. a helical vortex rope at a small aeration volume while a cylindrical vortex rope with a large amount of aeration. The preferable vortex rope distribution can suppress the swirl at the smaller flow rates, and is helpful to alleviate the pressure fluctuation in the draft tube. The analysis based on the vorticity transport equation indicates that the vortex has strong stretching and dilation in the vortex rope evolution. The baroclinic torque term does not play a major role in the vortex evolution most of the time, but will much increase for some specific aeration volumes. The present study also depicts that vortex rope is mainly associated with a pair of spiral vortex stretching and dilation sources, and its swirling flow is alleviated little by the baroclinic torque term, whose effect region is only near the draft tube inlet.


Author(s):  
Muhannad Altimemy ◽  
Bashar Attiya ◽  
Cosan Daskiran ◽  
I-Han Liu ◽  
Alparslan Oztekin

Abstract Computational fluid dynamics simulations are conducted to characterize the spatial and temporal characteristics of the turbulent flow fields inside Francis turbine operating at the design and partial load regimes. High-fidelity large eddy simulations turbulence model is applied to investigate the flow-induced vibrations in the draft tube of the unit. The water injection at 4% rate from the runner cone is implemented to control the flow-induced pressure fluctuations. The simulations are conducted at the turbine design point and two partial load operations with and without water injection. It has been demonstrated that the water injection has a profound influence in the turbulent flow structure and the pressure field inside the draft tube at the partial load operating conditions. To evaluate the effectiveness of the water injection techniques in mitigating flow-induced fluctuations, the probes at various locations along the wall of the draft tube are used to monitor the pressure signals. It appears to be a reduction in the level of pressure fluctuations by the water injection at both partial load operating regimes. However, we could not draw a firm conclusion about the level of mitigation of flow-induced vibrations. Simulations should be carried out for much longer flow time. Water injection hardly influenced the unit power generation. Hence water injection can be employed effectively without a major liability on the power generation.


Author(s):  
Muhannad Altimemy ◽  
Cosan Daskiran ◽  
Bashar Attiya ◽  
I-Han Liu ◽  
Alparslan Oztekin

Computational fluid dynamics simulations were performed on Francis turbine using Reynolds-averaged Navier-Stokes (RANS) with k-ω SST turbulence model. Simulations were conducted at the turbine’s best efficiency point with a Reynolds number of 2.01 × 107. Water injection was admitted from the runner cone in the stream-wise direction. The aim of this process was to investigate the influence of water injection on the turbine performance and the pressure pulsation. The water injection did not affect the nominal value of the turbine’s power generation. Straight vortex rope was observed at the centerline of the draft tube. Moreover, helix-shaped vortex ropes were obtained near the draft tube surface. The water injection expands the central vortex rope, but it did not suppress or disrupt the helix-shaped peripheral vortex rope near the draft tube surface. The pressure fluctuation became less regular after the water injection, but the fluctuation level remained similar.


Sign in / Sign up

Export Citation Format

Share Document