scholarly journals Delamination mechanism of GFRP sheet bonded on the reinforced concrete beams

2019 ◽  
Vol 258 ◽  
pp. 03009 ◽  
Author(s):  
Rudy Djamaluddin ◽  
Hijriah ◽  
Rita Irmawati ◽  
Faharuddin ◽  
Rossy T. Wahyuningsih

Fiber reinforced polymer (FRP) has been developed to be applied for a strengthening of the deteriorated structures. In the form of a sheet, the FRP may be applied for the strengthening of the structures by bonding it to the concrete surface. Glass composed FRP (GFRP) sheet is most commonly used due to its relatively lower cost compared to the other FRP materials. GFRP sheet is applied externally by bonding it on the concrete surface. The strengthened structures should be monitored periodically to ensure the health of the strengthened structures. Regarding the development of monitoring system of the strengthened structure, it is important to study the delamination phenomenon of the bonded GFRP. Therefore the delamination mechanism is important to be clarified. Many studies have been done to investigate the bonding characteristics of GFRP sheet under direct tensile loading. However, the studies on the bonding characteristics of GFRP sheet on the strengthened beams due to flexural loadings are still limited. A series of concrete beams strengthened with GFRP sheet on extreme tension surface were prepared. The beam specimens ware loaded under four-point bending test gradually up to the ultimate capacity. Results indicated that prior to final delamination, a local delamination occurred which was indicated by the suddenly decreasing of an applied load. The delamination of the GFRP sheet may be initiated by the flexural cracks occurred on the beams.

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Mehmet Mustafa Önal

Concrete beams were strengthened by wrapping the shear edges of the beams twice at 45° in opposite directions by either carbon fiber reinforced polymer (CFRP) or glass fiber reinforced polymer (GFRP). The study included 3 CFRP wrapped beams, 3 GFRP wrapped beams, and 3 control beams, all of which were 150×250×2200 mm and manufactured with C20 concrete and S420a structural steel at the Gazi University Technical Education Faculty labs, Turkey. Samples in molds were cured by watering in the open air for 21 days. Four-point bending tests were made on the beam test specimens and the data were collected. Data were evaluated in terms of load displacement, bearing strength, ductility, and energy consumption. In the CFRP and GFRP reinforced beams, compared to controls, 38% and 42%, respectively, strength increase was observed. In all beams, failure-flexural stress occurred in the center as expected. Most cracking was observed in the flexural region 4. A comparison of CFRP and GFRP materials reveals that GFRP enforced parts absorb more energy. Both materials yielded successful results. Thicker epoxy application in both CFRP and GFRP beams was considered to be effective in preventing break-ups.


2011 ◽  
Vol 255-260 ◽  
pp. 3077-3081 ◽  
Author(s):  
Lang Ni Deng ◽  
Hua Chen ◽  
Kan Kang

Four medium -scale reinforced concrete beams were constructed and tested to investigate the effectiveness of external poststrengthening with prestressed carbon fiber reinforced polymer (CFRP) plates. The various variables included the strengthening method and the amount of prestressing. The experiments consisted of one control beam, one nonprestressed CFRP-bonded beam, and two prestressed CFRP-bonded beams, all the beams were subjected to four-point bending tests. In comparison to the control beam and the nonprestressed CFRP-bonded beam, the cracking load, yield load, ultimate load and stiffness of the beams with bonded prestressed CFRP plates were increased. The failure mode of the prestressed CFRP-plated beams was not debonding, but concrete crushing. After the debonding of the CFRP plates, the behaviour of the bonded CFRP-plated beams changed to that of unbonded CFRP-plated beams due to the effect of the anchorage system. The ductility of the beams strengthened with CFRP plates having the anchorage system was considered high if the ductility index was above 3.


2010 ◽  
Vol 168-170 ◽  
pp. 549-552
Author(s):  
Yan Lei Wang ◽  
Qing Duo Hao ◽  
Jin Ping Ou

A new form of fiber reinforced polymer (FRP)-concrete composite beam is proposed in this study. The proposed composite beam consists of a GFRP box beam combined with a thin layer of concrete in the compression zone. The interaction between the GFRP beam and the concrete was obtained by bonding coarse-sand on the top flange of the GFRP beam. One GFRP box beam and one GFRP-concrete composite beam were investigated in four-point bending test. Load-deflection response, mid-span longitudinal strain distributions and interface slip between GFRP beam and the concrete for the proposed composite beam were studied. Following conclusions are drawn from this study: (1) the stiffness and strength of the composite beam has been significantly increased, and the cost-to-stiffness ratio of the composite beam has been drastically reduced comparing with GFRP-only box beam; (2) a good composite action has been achieved between the GFRP beam and the concrete; (3) crushing of concrete in compression defines flexural collapse of the proposed composite beam..


2016 ◽  
Vol 78 (5-3) ◽  
Author(s):  
Norliyati Mohd Amin ◽  
Nur Aqilah Aziz ◽  
Ilya Joohari ◽  
Anizahyati Alisibramulisi

Cracks in concrete structure have always been a big threat on the strength of the concrete. Crack is one of the common deterioration observed in reinforced concrete beams and slabs. Concrete cracking is a random process, highly variable and influenced by many factors. To restore the structural capacity of the concrete damages, retrofitting and strengthening are required. There are several techniques that are used for retrofitting and strengthening reported in the literature [1], [2], [3]. This paper investigates the strength performance of retrofitting and strengthening methods of reinforced concrete one-way slab. Flexural bending test are performed on three different concrete slab of size 1000 mm x 500 mm x 75 mm. The methods that are used for retrofit are epoxy injection and patching and for the strengthening is lamination of carbon fiber reinforced polymer. The slabs were loaded to a certain stage where the cracks were formed for retrofitting and strengthening procedure. The achieved failure mode and load capacity of the concrete slab were observed. The repaired techniques for restoring and improving the structural capacity of cracked concrete slabs were analyzed. The ultimate load achieved for the epoxy injection laminate was 19.60 kN followed by CFRP laminate and patching that were 17.64 kN and 17.03 kN respectively. While the deflection value for the three specimens were 14.42 mm, 4.49 mm and 7.036 mm.  


2011 ◽  
Vol 243-249 ◽  
pp. 621-624
Author(s):  
Gui Bing Li ◽  
Yu Gang Guo

Bonding fiber reinforced polymer (FRP) laminates to the tension face of RC members has been proven to be an effective method to improve the flexural strength. However, structural members are not only needed to have adequate strength, but also to have adequate performance of deformation at service load levels. To evaluate the deflection of externally FRP-strengthened RC beams, a total of 18 RC beams, including 16 beams strengthened with CFRP laminate under different preload levels and 2 control beams, were tested. Based on the assumption that the section of the beam behaves a tri-linear moment-curvature response characterized by pre-crack stage, post-crack stage and failure stage and the test results, this paper presents a modified model to evaluate the deflection of CFRP-strengthened RC beams. The present modified model was verified by the similar test results, and shows a good agreement with the test results.


2016 ◽  
Vol 707 ◽  
pp. 51-59 ◽  
Author(s):  
Osama Ahmed Mohamed ◽  
Rania Khattab

The behaviour of reinforced concrete beam strengthened with Carbon Fiber Reinforced Polymer (CFRP) and Glass fiber reinforced polymer GFRP laminates was investigated using finite element models and the results are presented in this paper. The numerical investigation assessed the effect of the configuration of FRP strengthening laminates on the behaviour of concrete beams. The load-deflection behaviour, and ultimate load of strengthened beam were compared to those of un-strengthened concrete beams. It was shown that using U-shaped FRP sheets increased the ultimate load. The stiffness of the strengthed beam also increased after first yielding of steel reinforcing bars. At was also observed that strengthening beams with FRP laminates to one-fourth of the beam span, modifies the failure of the beam from shear-controlled near the end of the unstrengthened beam, to flexure-controlled near mid-span. CFRP produced better results compared GFRP in terms of the ability to enhance the behavior of strengthenened reinforced concrete beams.


Sign in / Sign up

Export Citation Format

Share Document