scholarly journals Performance evaluation of an adsorption refrigeration system powered by solar heat storage based on Moroccan irradiation

2020 ◽  
Vol 307 ◽  
pp. 01014
Author(s):  
Hicham BOUSHABA ◽  
Abdelaziz MIMET ◽  
Mohammed El GANAOUI ◽  
Abderrahman MOURADI

The aim of this paperwork is to provide a performance comparative study of an adsorption refrigeration system powered by solar heat storage based on Moroccan irradiation. The system operates with ammonia as refrigerant and activated carbon as adsorbent. A parabolic through collector is used to collect the solar energy and store it in a heat storage tank. A dynamic simulation program interpreting the real behavior of the system has been developed. The pressure, temperature and adsorbed mass profiles in the Adsorber have been revealed. The system performance is estimated in terms of the specific cooling power (SCP) and the solar coefficient of performance (SCOP). The solar irradiation and the real ambient temperature variations corresponding to the six climatic zones in Morocco are considered. The effect of those conditions on the performance of the system has been investigated. The results show the capability of our system to realize more than one cycle and produce cold during the day. For an optimal configuration of the system and operating conditions of evaporation temperature, Tev=0 °C, condensation temperature, Tcon=30 °C and generation temperature, T3=100 °C, the process could achieve a SCP of 151 W.kg-1and its solar COP could attain 0.148. The system performances improve especially in sunny area.

2018 ◽  
Vol 26 (03) ◽  
pp. 1850025
Author(s):  
Hicham Boushaba ◽  
Abdelaziz Mimet

The aim of this paper is to provide a global study of an adsorption refrigeration machine driven by solar heat storage and collected by parabolic trough collector. The system operates with ammonia (as refrigerant) and activated carbon (as adsorbent). A mathematical model interpreting the progression of the heat and the mass transfer at each element of the prototype has been developed. The solar irradiation and the real ambient temperature variations corresponding to a usual summer day in Tetouan (Morocco) are considered. The system performance is evaluated trough specific cooling power (SCP) as well as solar coefficient of performance (SCOP), which was estimated by a dynamic simulation cycle. The pressure, temperature and adsorbed mass profiles in the Adsorber have been calculated. The effects of significant design and operating parameters on the system performance have been investigated. The results show the capability of our system to realize an encouraging performance and to overcome the intermittence of the adsorption refrigeration machines. For a daily solar irradiation of 18[Formula: see text]MJ[Formula: see text]m[Formula: see text] and operating conditions of evaporation temperature [Formula: see text]C, condensation temperature [Formula: see text]C and generation temperature [Formula: see text]C, the results show that the process could achieve an SCP of 115[Formula: see text]W[Formula: see text]kg[Formula: see text] and it could produce a daily specific cooling capacity of 3310[Formula: see text]kJ[Formula: see text]kg[Formula: see text], whereas its SCOP could attain 0.141.


2019 ◽  
Vol 969 ◽  
pp. 199-204
Author(s):  
Shaik Mohammad Hasheer ◽  
Kolla Srinivas

Now a days R134a can be used in domestic refrigerators and in air conditioning of automobiles. As per Kyoto protocol the usage of R134a is restricted due to their higher GWP value. The GWP value of this refrigerant is around 1430. So in this article, thermodynamic analysis of HFC-152a, HFO refrigerants-1234ze(E) and 1234yf was done in a household refrigeration system as direct substitute to HFC-134a.The performance of the household refrigerator was compared in terms of outlet temperature of the compressor, volumetric cooling capacity (VCC), refrigeration effect, work done by the compressor and coefficient of performance (COP). The entire analysis is carried out at various operating conditions of condenser and evaporator temperatures i.e. condensation temperature of 25°C,35°C & 45°C and evaporating temperatures ranging between −20°C to 10°C.From the theoretical results, it can be concluded that R1234yf can be used as a direct substitute to R134a.


2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
V. Baiju ◽  
C. Muraleedharan

This paper proposes a new approach for the performance analysis of a single-stage solar adsorption refrigeration system with activated carbon-R134a as working pair. Use of artificial neural network has been proposed to determine the performance parameters of the system, namely, coefficient of performance, specific cooling power, adsorbent bed (thermal compressor) discharge temperature, and solar cooling coefficient of performance. The ANN used in the performance prediction was made in MATLAB (version 7.8) environment using neural network tool box.In this study the temperature, pressure, and solar insolation are used in input layer. The back propagation algorithm with three different variants namely Scaled conjugate gradient, Pola-Ribiere conjugate gradient, and Levenberg-Marquardt (LM) and logistic sigmoid transfer function were used, so that the best approach could be found. After training, it was found that LM algorithm with 9 neurons is most suitable for modeling solar adsorption refrigeration system. The ANN predictions of performance parameters agree well with experimental values with R2 values close to 1 and maximum percentage of error less than 5%. The RMS and covariance values are also found to be within the acceptable limits.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4707
Author(s):  
Piotr Boruta ◽  
Tomasz Bujok ◽  
Łukasz Mika ◽  
Karol Sztekler

Adsorption refrigeration systems are promising, sustainable solutions for many cooling applications. The operating range and the performance of an adsorption cooling cycle are strongly dependent on the properties of adsorbents, adsorbates, and bed coatings. Therefore, further research and analysis may lead to improved performance of adsorption coolers. In this paper, studies on working pairs using natural refrigerants and the properties of adsorbent coatings were reviewed. The selected working pairs were then thermodynamically characterised and ranked in terms of refrigerant evaporation temperature values. This was found to be a key parameter affecting the applicability of a given adsorbent/adsorbate pair and the value of SCP (Specific Cooling Power), COP (Coefficient of Performance) parameters, which are now commonly used comparison criteria of adsorption chillers. In the analysis of the coating studies, the focus was on the effect of individual parameters on the performance of the cooling system and the effect of using coated beds compared to packed beds. It was found that a fundamental problem in comparing the performance of different cooling systems is the use of different operating conditions during the tests. Therefore, the analysis compares the performance of the systems along with the most important thermodynamic cycle parameters for the latest studies.


2015 ◽  
Vol 23 (04) ◽  
pp. 1550033 ◽  
Author(s):  
Anirban Sur ◽  
Randip K. Das

The aim of this paper is to develop a complete, precise and simple numerical model based on the thermophysical properties of an adsorptive cooling system (using activated carbon–methanol pair), analyze and discuss the heat and mass transfer processes and identify the parameters which influence the system performance. In the design of adsorption refrigeration system, the characteristics of both adsorbate–adsorbent pairs and system operating conditions are very important. So in this model, different thermophysical properties of working pair such as, specific heat, density, isosteric heat of adsorption and desorption, and different temperatures of the system are considered. A simulation code, written in FORTRAN, is carried out. The performance of the system is assessed in terms of refrigeration effect and coefficient of performance (COP).


2020 ◽  
Vol 8 (2) ◽  
pp. 3-9
Author(s):  
E.A. Belyanovskaya ◽  
◽  
G.M. Pustovoy ◽  
A.I. Sklyarenko ◽  
M.P. Sukhyy ◽  
...  

The work is focused on the development of an effective algorithm for calculating the operational characteristics of a steamcompressive chilling machine with an adsorptive chilling unit, which involves a cold box, an adsorber, an evaporator and a condenser, water being used as a refrigerant. An algorithm for calculating the operating parameters of the adsorptive chilling unit has been developed, which includes the determination of the cooling capacity of the steam compressor refrigeration unit, the heat load on the condenser, the power consumed by the compressor, the coefficient of performance of the steam compressor refrigeration unit, as well as the calculation of the mass of water, the mass of the adsorbent, the refrigerating capacity, the coefficient of performance of the adsorptive chilling unit and the coefficient of useful energy utilization of a steam compressive chilling machine with an adsorption chilling unit. The chilling capacity and the coefficient of performance of the adsorption chilling unit are estimated under the operating conditions of a typical steam compression chilling machine. The crucial factors affecting the efficiency of the adsorptive chilling unit are analyzed. It has been established that the chilling capacity, the coefficient of performance of the adsorption refrigeration module and the energy efficiency of the installation are determined by the thermal load on the condenser, and, therefore, by the mass of water that is desorbed and evaporated. The coefficient of performance of the adsorption chilling unit and the efficiency of the steam compressor chilling machine with the adsorptive chilling unit are estimated to be 0.878 and 4.64. The criteria for the selection of adsorbents for the adsorption module are analyzed. The temperature of regeneration is determined by the temperatures in the condenser, and the limit adsorption affects the mass of the adsorbent and the size of the adsorber. A comparison of the efficiency of adsorptive chi l l ing uni t based on silicoaluminophosphates and composite adsorbents «silica gel – sodium acetate» is carried out. The prospects of using composites «silica gel – СН3СООNa» are shown. The optimal composition of the composite was established, which corresponds to the minimal size of the adsorber, (80% sodium acetate and 20% silica gel). The prospects of using adsorptive conversion of thermal energy for utilization of low-potential thermal energy during the operation of steam compressive chilling machine are shown. Keywords: adsorptive conversion of heat energy, composite adsorbent, steam compressive chilling unit, adsorption, adsorptive capacity.


Author(s):  
Vikas Kumar ◽  
Gulshan Sachdeva ◽  
Sandeep Tiwari ◽  
Parinam Anuradha ◽  
Vaibhav Jain

A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system does not dissipate its heat directly to the evaporator of the ERS; instead, water circulates between the condenser of VCRS and the evaporator of ERS to exchange the heat. Seven ejectors of different geometries have been used in the ERS; however, all the ejectors could not maintain thermal equilibrium at the desired operating conditions. The compressor of the cascaded VCRS consumed 1.3 times less power than the noncascaded VCRS. Furthermore, the cascaded system provided a maximum 87.74% improvement in COP over the noncascaded system for the same operating conditions. The performance of the system remained constant until the critical condenser pressure of the ERS.


2020 ◽  
Vol 15 (3) ◽  
pp. 398-408
Author(s):  
I Ouelhazi ◽  
Y Ezzaalouni ◽  
L Kairouani

Abstract From the last few years, the use of efficient ejector in refrigeration systems has been paid a lot of attention. In this article a description of a refrigeration system that combines a basic vapor compression refrigeration cycle with an ejector cooling cycle is presented. A one-dimensional mathematical model is developed using the flow governing thermodynamic equations based on a constant area ejector flow model. The model includes effects of friction at the constant-area mixing chamber. The current model is based on the NIST-REFPROP database for refrigerant property calculations. The model has basically been used to determine the effect of the ejector geometry and operating conditions on the performance of the whole refrigeration system. The results show that the proposed model predicts ejector performance, entrainment ratio and the coefficient of performance of the system and their sensitivity to evaporating and generating temperature of the cascade refrigeration cycle. The simulated performance has been then compared with the available experimental data from the literature for validation.


2016 ◽  
Vol 138 (5) ◽  
Author(s):  
Shahram Derakhshan ◽  
Alireza Yazdani

In critical situations such as floods and earthquakes, the relief forces require a refrigeration for pharmaceuticals and vaccines, which could operate without an electrical energy and the alternative energies, such as solar energy, engine exhaust gases heat, and wind energy. In this paper, a refrigeration cycle has been modeled as an adsorption refrigeration cycle with an activated carbon/methanol as adsorbent/adsorbate pair and two sources of energy—solar energy and engine exhaust gases heat. The solar cycle had a collector with area of 1 m2 and the exhaust gas cycle included a heat exchanger with 100 °C temperature difference between inlet and outlet gases. The temperature profile in adsorbent bed, evaporator, and condenser was obtained from modeling. Moreover, the pressure profile, overall heat transfer coefficient of collector and adsorbent bed, concentration, and the solar radiation were reported. Results represented the coefficient of performance (COP) of 0.55, 0.2, and 0.56 for complete system, solar adsorption refrigeration, and exhaust heat adsorption refrigeration, respectively. In addition, exhaust heat adsorption refrigeration has a value of 2.48 of specific cooling power (SCP). These results bring out a good performance of the proposed model in the climate of Iran.


Sign in / Sign up

Export Citation Format

Share Document