Six Cases of Leukaemia After Irradiation

1962 ◽  
Vol 2 (01) ◽  
pp. 80-86
Author(s):  
S. Plesničar ◽  
S. Modic ◽  
B. Cernelč

SummaryThe authors describe six cases of leukaemia in patients exposed to X-rays. Clinical course and blood values are given. All known details are submitted, since it is extremely important to gather all relevant information in cases of this kind.

CJEM ◽  
2020 ◽  
Vol 22 (S1) ◽  
pp. S14-S14
Author(s):  
S. Leduc ◽  
G. Wells ◽  
V. Thiruganasambandamoorthy ◽  
Z. Cantor ◽  
P. Kelly ◽  
...  

Introduction: An increasing number of Canadian paramedic services are creating Community Paramedic programs targeting treatment of long-term care (LTC) patients on-site. We explored the characteristics, clinical course and disposition of LTC patients cared for by paramedics during an emergency call, and the possible impact of Community Paramedic programs. Methods: We completed a health records review of paramedic call reports and emergency department (ED) records between April 1, 2016 and March 31, 2017. We utilized paramedic dispatch data to identify emergency calls originating from LTC centers resulting in transport to one of the two EDs of the Ottawa Hospital. We excluded patients with absent vital signs, a Canadian Triage and Acuity Scale (CTAS) score of 1, and whose transfer to hospital were deferrable or scheduled. We stratified remaining cases by month and selected cases using a random number generator to meet our apriori sample size. We collected data using a piloted standardized form. We used descriptive statistics and categorized patients into groups based on the ED care received and if the treatment received fit into current paramedic medical directives. Results: Characteristics of the 381 included patients were mean age 82.5 years, 58.5% female, 59.7% hypertension, 52.6% dementia and 52.1% cardiovascular disease. On arrival at hospital, 57.7% of patients waited in offload delay for a median time of 45 minutes (IQR 33.5-78.0). We could identify 4 groups: 1) Patients requiring no treatment or diagnostics in the ED (7.9%); 2) Patients receiving ED treatment within current paramedic medical directives and no diagnostics (3.2%); 3) Patients requiring diagnostics or ED care outside current paramedic directives (54.9%); and 4) patients requiring admission (34.1%). Most patients were discharged from the ED (65.6%), and 1.1% died. The main ED diagnoses were infection (18.6%) and musculoskeletal injury (17.9%). Of the patients that required ED care but were discharged, 64.1% required x-rays, 42.1% CT, and 3.4% ultrasound. ED care included intravenous fluids (35.7%), medication (67.5%), antibiotics (29.4%), non-opioid analgesics (29.4%) and opioids (20.7%). Overall, 11.1% of patients didn't need management beyond current paramedic capabilities. Conclusion: Many LTC patients could receive care by paramedics on-site within current medical directives and avoid a transfer to the ED. This group could potentially grow using Community Paramedics with an expanded scope of practice.


2021 ◽  
Vol 56 (2) ◽  
pp. 110-115
Author(s):  
Jonathan Roth ◽  
Tali Jonas Kimchi ◽  
Ben Shofty ◽  
Ariel Agur ◽  
Liat Ben-Sira ◽  
...  

Background: Mechanical shunt malfunction may lead to significant morbidity and mortality. Shunt series assessments help evaluate shunt integrity; however, they are of limited value in the area of the skull due to skull curvature, thickness, and air sinuses. We describe the role of 3D bone reconstruction CT (3DCT) in demonstrating the shunt integrity over the skull, comparing this technique to skull X-rays (SXR). Methods: Data were collected retrospectively for shunted patients with concurrent SXR and 3DCT and for patients presenting with shunt failures at the region of the skull, including clinical course and radiological findings. We compared the SXR and 3DCT findings. The 3DCT was reconstructed from standard diagnostic CT protocols performed during evaluation of suspected shunt malfunction and not thin-slice CT protocols. Results: Forty-eight patients with 57 shunts underwent SXR and 3DCT. Interobserver agreement was high for most variables. Both SXR and 3DCT had a high sensitivity, specificity, and accuracy identifying tubing disconnections (between 0.83 and 1). Full valve type and setting were significantly more accurate based on SXR versus 3DCT (>90 vs. <20%), and valve integrity was significantly more readily verified on 3DCT versus SXR (100 vs. 52%). Conclusions: 3DCT and SXR complement each other in diagnosing mechanical shunt malfunctions over the skull. The main limitation of 3DCT is identification of valve type and settings, which are clearer on SXR, while the main limitation of SXR is a less ability to evaluate valve integrity. 3DCT also enables an intuitive 3D understanding of the shunt tubing over the skull.


1986 ◽  
Vol 96 (2) ◽  
pp. 231-238 ◽  
Author(s):  
M. E. Kilpatrick ◽  
N. I. Girgis ◽  
M. W. Yassin ◽  
A. A. Abu El Ella

SUMMARYIn developing countries tuberculous meningitis is a difficult infection to differentiate from other central nervous system (CNS) infections. This paper presents the history, physical findings, laboratory data, and clinical course of 100 patients who were admitted to a special ward and had CSF cultures positive for Mycobacterium tuberculosis. Fifty-four patients were comatose when admitted and 76 had meningeal signs. Mean admission CSF values were WBC 531, glucose 23 mg/dl, and protein 166 mg/dl. Only two CSF AFB smears were positive. Sixty-one percent of the chest X-rays taken were consistent with pulmonary tuberculous and 39% were normal. Twenty-four patients died within the first week after admission, before the clinical diagnosis was made and anti-tuberculous therapy could be started. Fifty-three of 76 patients given antituberculous therapy died. Neurologic sequelae developed in 48% of the survivors. The high mortality and morbidity rates in this patient-group were due to the severity of illness on admission and the predominance of children (54%).


2019 ◽  
Vol 42 ◽  
Author(s):  
Charlie Kurth

Abstract Recent work by emotion researchers indicates that emotions have a multilevel structure. Sophisticated sentimentalists should take note of this work – for it better enables them to defend a substantive role for emotion in moral cognition. Contra May's rationalist criticisms, emotions are not only able to carry morally relevant information, but can also substantially influence moral judgment and reasoning.


1994 ◽  
Vol 144 ◽  
pp. 82
Author(s):  
E. Hildner

AbstractOver the last twenty years, orbiting coronagraphs have vastly increased the amount of observational material for the whitelight corona. Spanning almost two solar cycles, and augmented by ground-based K-coronameter, emission-line, and eclipse observations, these data allow us to assess,inter alia: the typical and atypical behavior of the corona; how the corona evolves on time scales from minutes to a decade; and (in some respects) the relation between photospheric, coronal, and interplanetary features. This talk will review recent results on these three topics. A remark or two will attempt to relate the whitelight corona between 1.5 and 6 R⊙to the corona seen at lower altitudes in soft X-rays (e.g., with Yohkoh). The whitelight emission depends only on integrated electron density independent of temperature, whereas the soft X-ray emission depends upon the integral of electron density squared times a temperature function. The properties of coronal mass ejections (CMEs) will be reviewed briefly and their relationships to other solar and interplanetary phenomena will be noted.


2000 ◽  
Vol 179 ◽  
pp. 263-264
Author(s):  
K. Sundara Raman ◽  
K. B. Ramesh ◽  
R. Selvendran ◽  
P. S. M. Aleem ◽  
K. M. Hiremath

Extended AbstractWe have examined the morphological properties of a sigmoid associated with an SXR (soft X-ray) flare. The sigmoid is cospatial with the EUV (extreme ultra violet) images and in the optical part lies along an S-shaped Hαfilament. The photoheliogram shows flux emergence within an existingδtype sunspot which has caused the rotation of the umbrae giving rise to the sigmoidal brightening.It is now widely accepted that flares derive their energy from the magnetic fields of the active regions and coronal levels are considered to be the flare sites. But still a satisfactory understanding of the flare processes has not been achieved because of the difficulties encountered to predict and estimate the probability of flare eruptions. The convection flows and vortices below the photosphere transport and concentrate magnetic field, which subsequently appear as active regions in the photosphere (Rust &amp; Kumar 1994 and the references therein). Successive emergence of magnetic flux, twist the field, creating flare productive magnetic shear and has been studied by many authors (Sundara Ramanet al.1998 and the references therein). Hence, it is considered that the flare is powered by the energy stored in the twisted magnetic flux tubes (Kurokawa 1996 and the references therein). Rust &amp; Kumar (1996) named the S-shaped bright coronal loops that appear in soft X-rays as ‘Sigmoids’ and concluded that this S-shaped distortion is due to the twist developed in the magnetic field lines. These transient sigmoidal features tell a great deal about unstable coronal magnetic fields, as these regions are more likely to be eruptive (Canfieldet al.1999). As the magnetic fields of the active regions are deep rooted in the Sun, the twist developed in the subphotospheric flux tube penetrates the photosphere and extends in to the corona. Thus, it is essentially favourable for the subphotospheric twist to unwind the twist and transmit it through the photosphere to the corona. Therefore, it becomes essential to make complete observational descriptions of a flare from the magnetic field changes that are taking place in different atmospheric levels of the Sun, to pin down the energy storage and conversion process that trigger the flare phenomena.


Author(s):  
R. F. Bils ◽  
W. F. Diller ◽  
F. Huth

Phosgene still plays an important role as a toxic substance in the chemical industry. Thiess (1968) recently reported observations on numerous cases of phosgene poisoning. A serious difficulty in the clinical handling of phosgene poisoning cases is a relatively long latent period, up to 12 hours, with no obvious signs of severity. At about 12 hours heavy lung edema appears suddenly, however changes can be seen in routine X-rays taken after only a few hours' exposure (Diller et al., 1969). This study was undertaken to correlate these early changes seen by the roengenologist with morphological alterations in the lungs seen in the'light and electron microscopes.Forty-two adult male and female Beagle dogs were selected for these exposure experiments. Treated animals were exposed to 94.5-107-5 ppm phosgene for 10 min. in a 15 m3 chamber. Roentgenograms were made of the thorax of each animal before and after exposure, up to 24 hrs.


Author(s):  
R. H. Duff

A material irradiated with electrons emits x-rays having energies characteristic of the elements present. Chemical combination between elements results in a small shift of the peak energies of these characteristic x-rays because chemical bonds between different elements have different energies. The energy differences of the characteristic x-rays resulting from valence electron transitions can be used to identify the chemical species present and to obtain information about the chemical bond itself. Although these peak-energy shifts have been well known for a number of years, their use for chemical-species identification in small volumes of material was not realized until the development of the electron microprobe.


Author(s):  
E. A. Kenik ◽  
J. Bentley

Cliff and Lorimer (1) have proposed a simple approach to thin foil x-ray analy sis based on the ratio of x-ray peak intensities. However, there are several experimental pitfalls which must be recognized in obtaining the desired x-ray intensities. Undesirable x-ray induced fluorescence of the specimen can result from various mechanisms and leads to x-ray intensities not characteristic of electron excitation and further results in incorrect intensity ratios.In measuring the x-ray intensity ratio for NiAl as a function of foil thickness, Zaluzec and Fraser (2) found the ratio was not constant for thicknesses where absorption could be neglected. They demonstrated that this effect originated from x-ray induced fluorescence by blocking the beam with lead foil. The primary x-rays arise in the illumination system and result in varying intensity ratios and a finite x-ray spectrum even when the specimen is not intercepting the electron beam, an ‘in-hole’ spectrum. We have developed a second technique for detecting x-ray induced fluorescence based on the magnitude of the ‘in-hole’ spectrum with different filament emission currents and condenser apertures.


Author(s):  
C.W. Akey ◽  
M. Szalay ◽  
S.J. Edelstein

Three methods of obtaining 20 Å resolution in sectioned protein crystals have recently been described. They include tannic acid fixation, low temperature embedding and grid sectioning. To be useful for 3-dimensional reconstruction thin sections must possess suitable resolution, structural fidelity and a known contrast. Tannic acid fixation appears to satisfy the above criteria based on studies of crystals of Pseudomonas cytochrome oxidase, orthorhombic beef liver catalase and beef heart F1-ATPase. In order to develop methods with general applicability, we have concentrated our efforts on a trigonal modification of catalase which routinely demonstrated a resolution of 40 Å. The catalase system is particularly useful since a comparison with the structure recently solved with x-rays will permit evaluation of the accuracy of 3-D reconstructions of sectioned crystals.Initially, we re-evaluated the packing of trigonal catalase crystals studied by Longley. Images of the (001) plane are of particular interest since they give a projection down the 31-screw axis in space group P3121. Images obtained by the method of Longley or by tannic acid fixation are negatively contrasted since control experiments with orthorhombic catalase plates yield negatively stained specimens with conditions used for the larger trigonal crystals.


Sign in / Sign up

Export Citation Format

Share Document