scholarly journals A Comparative Evaluation of Microleakage of Glass Ionomer Restoration with Different Surface Protectors - an In-Vitro Study

2014 ◽  
Vol 02 (02) ◽  
pp. 105-108 ◽  
Author(s):  
Nupur Ninawe ◽  
Ullal Nayak ◽  
Priya Nagar ◽  
Vishal Khandelwal ◽  
Suyash Jain ◽  
...  

Abstract Aim: All the restorative material whatsoever introduced till-date have an inherent disadvantage of micro-leakage measurable different grades. The present study comparatively evaluates the micro-leakage of glass ionomer restoration with different surface protection methods. Methodology: 36 premolars were obtained without any cracks or restorations for the study. Teeth were stored in distilled water containing thymol crystals till the beginning of the study. The teeth were randomly divided into 3 groups based on surface protectors used. Group I is GC Fuji Varnish, Group II is vaseline and Group III is G-Coat plus along with GIC restoration. Class V cavities were prepared of dimensions mesio-distal width of 3 mm, occluso-gingival length of 2 mm, and a depth of 1.5 mm on buccal and lingual surfaces with a high-speed hand-piece with air-water spray. Results: Kruskal- Wallis test was applied and Vaseline group showed significantly less micro-leakage compared to G-Coat plus i.e. G-Coat plus exhibited significantly higher microleakage compared to other groups. Conclusion: Evaluation of micro-leakage of glass ionomer cements using various surface protecting agents, Vaseline was considered the best surface protecting agent maintaining the water balance and showing no micro-leakage.

2021 ◽  
Vol 10 (33) ◽  
pp. 2769-2772
Author(s):  
Arjun Sajjeev ◽  
Ashwini Tumkur Shivkumar ◽  
Sowmya Halasabalu Kalgeri

BACKGROUND Marginal integrity of glass ionomer as a restorative material is an important factor for the longevity of the restoration. Class V and cervical abrasions are the most critical and challenging lesions for restorations. The choice of material for restoring class V and cervical abrasions is glass ionomer cement (GIC). Sensitivity to moisture contact during the early setting stages is the drawback of GIC. To overcome the drawback, modifications of glass ionomer cement were made by the addition of chitosan. Chitosan (CH) is a natural linear polysaccharide obtained partially and fully by deacetylated chitin compounds, which are found in crab and shrimp shells, with properties like nontoxicity, biodegradability, bioadhesive, biocompatibility, and biorenewabilty which has led to its use in various fields. Thus, this study intended to evaluate the microleakage of conventional glass ionomer cement and chitosan modified glass ionomer cement using a spectrophotometer. METHODS 60 teeth extracted for orthodontic propose were selected for the study and randomly divided into two groups, class V cavities were prepared on the buccal surface and samples were restored with conventional glass ionomer cement and chitosan modified glass ionomer cement respectively, teeth were immersed in 0.5 % methylene blue for 24 hours and assessed using a spectrophotometer. RESULTS The data were analysed using the Unpaired T - test, and with statistical package for social sciences (SPSS) for Windows, version 25.0 (IBM Corp., Armonk, N.Y., USA). The confidence interval was set at 95 % and values of P < 0.05 were interpreted as statistically significant. CONCLUSIONS The study concluded that the addition of chitosan improves the mechanical properties of conventional glass ionomer cement, and a spectrophotometer can be used as a better evaluation tool in assessing microleakage. KEY WORDS Chitosan Modified GIC, Glass Ionomer Cement, Microleakage, Spectrophotometer


2009 ◽  
Vol 03 (03) ◽  
pp. 178-184 ◽  
Author(s):  
Hacer Deniz Arisu ◽  
Evrim Eliguzeloglu ◽  
Mine Betul Uctasli ◽  
Huma Omurlu ◽  
Emin Turkoz

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate the effect of multiple consecutive adhesive coatings of a one-step self-etch adhesive on microleakage of Class V cavities.Methods: Standardized box shaped Class V cavities were prepared onto the buccal side of forty five non-carious human premolar teeth. The teeth were randomly divided into three groups of fifteen teeth in each and restored as: Group I- one-step self-etch adhesive resin (Clearfil S3, Kuraray Co. Ltd., Osaka, Japan) was applied according to the manufacturer�s instructions, Group II- two consecutive same one-step self-etch adhesive application was performed, and Group III- three consecutive same one-step self-etch adhesive application was performed. After the adhesive applications light curing unit was activated for 20 seconds and the cavities were restored with a composite resin. The restorations were finished with aluminum oxide discs and the specimens were stored in water at room temperature for 24 hours before they were immersed in 2% methylene blue for 48 hours. The dye penetration was examined under a stereomicroscope and the asymtotic significance were analysed with Kruskall Wallis and Mann Whitney U tests and dentin-enamel margins were compared with each other with Wilcoxon Signed Rank test.Results: The microleakage at the dentinal margins of Class V cavities were significantly decreased with two (Group II) and three (Group III) consecutive adhesive applications (P<.05). There was no significant difference between Group I, Group II and Group III at the enamel margins (P<.05). The microleakage at the dentinal margins were significantly higher than the enamel margins in Group I and Group II but in Group III there was no statistically significant difference (P<.05).Conclusions: Within the limitations of this in vitro study, it may be concluded that three consecutive applications of the one-step self-etch adhesive resin provided better sealing than the one coat of adhesive resin at the dentinal margins of Class V cavities. (Eur J Dent 2009;3:178-184)


Author(s):  
Jyoti Sharma ◽  
Bhagwat Swaroop Sharma ◽  
Dr Updesh Masih ◽  
Manisha Upadhyay ◽  
Nilotpol Kashyap ◽  
...  

Background: For the past several years, different techniques and materials have been examined to reduce microleakage in class V restorations. Thus both the quantity and quality of polymerization can be improved with proper selection of light curing modes and clinical placement techniques Aim: The aim of the present study was to evaluate and compare which is one of the best placement technique and mode of curing to reduce microleakage. Material and method: Class V cavities were prepared in 135 teeth. Teeth were divided into 3 groups of 45 each using three different placement technique with two different composite. Each group was further subdivided into 15 teeth cured by different curing modes. Results: The ‘p’ value of the mean scores of all the groups when cured with high intensity mode is 0.004 (≤0.05) indicating that the results are statistically significant. But the ‘p’ value of the mean scores of all the groups when cured with pulse delay and ramped mode is 0.603 and 2.167(≥0.05) indicating that the results are not statistically significant.  The ‘p’ value of the mean scores of group I and group II when cured with different mode is 0.065 and 0.085(≥0.05) indicating that the results are not statistically significant. But the ‘p’ value of the mean scores of the group III when cured with different mode is 0.001(≤0.05) indicating that the results are statistically significant. Conclusion: Split increment horizontal technique showed least microleakage despite of curing modes. Although curing modes did not show statistically significant results but high intensity showed least microleakage. Keywords: composite, G.V Black Classification, polymerization shrinkage, curing modes


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


Materials ◽  
2020 ◽  
Vol 13 (7) ◽  
pp. 1700
Author(s):  
Atsushi Kameyama ◽  
Aoi Saito ◽  
Akiko Haruyama ◽  
Tomoaki Komada ◽  
Setsuko Sugiyama ◽  
...  

This study aimed to examine the marginal seal between various commercial temporary restorative materials and exposed dentin/built-up composite. Sixty bovine incisors were cut above the cemento-enamel junction, and half of the dentin was removed to form a step, which was built up using flowable resin composite. The root canals were irrigated, filled with calcium hydroxide, and sealed using one of six temporary sealing materials (hydraulic temporary restorative material, temporary stopping material, zinc oxide eugenol cement, glass-ionomer cement, auto-cured resin-based temporary restorative material, and light-cured resin-based temporary restorative material) (n = 10 for each material). The samples were thermocycled 500 times and immersed in an aqueous solution of methylene blue. After 2 days, they were cut along the long axis of the tooth and the depth of dye penetration was measured at the dentin side and the built-up composite side. For the margins of the pre-endodontic resin composite build-up, the two resin-based temporary restorative materials showed excellent sealing. Hydraulic temporary restorative material had a moderate sealing effect, but the sealing effect of both zinc oxide eugenol cement and glass-ionomer cement was poorer.


2013 ◽  
Vol 14 (1) ◽  
pp. 56-60 ◽  
Author(s):  
S Nagalaxmi Reddy ◽  
DN Jayashankar ◽  
Mohanthomas Nainan

ABSTRACT Aim Aim of this study was to compare class II composite restoration using flowable composites as lining with various thickness and curing techniques by evaluating cervical marginal microleakage. Materials and methods Fifty intact molars, each prepared with two box-only class II cavities, were randomly divided into five groups: Group I, P60 filling alone; group II, ultrathin flowable composite lining (0.5-1mm) cocured with overlying composite; group III, thin lining (1-1.5) cocured with overlying composite; group IV, ultrathin lining (0.5-1 mm) precured and group V, thin lining (1-1.5) precured. The teeth were then thermocycled for 1500 cycles (between 5 and 60 °C) and immersed in dye for 24 hours. Cervical microleakage was measured as the extent of dye penetration. Results Cocured specimens (groups II and III) showed least microleakage and control specimens (group I) showed maximum microleakage. On comparison of curing techniques, cocured specimens (groups II and III) showed less microleakage than precured (groups IV and V). On comparison of lining thickness and type of curing, group IV showed less microleakage than group V. Groups II and III were statistically not significant. Conclusion It was concluded from the results that ultrathin cocured flowable composite lining specimens improved the marginal sealing with decreased microleakage. Clinical significance In this study, the application of additional flowable composite lining with various thicknesses presented different influences in marginal quality of class II box only composite restorations. A new technique applying an ultrathin flowable composite lining with cocuring technique improved the marginal sealing with decreased microleakage. Restorations with thin lining presented reduced marginal integrity after thermocycling. How to cite this article Reddy SN, Jayashankar DN, Nainan M, Shivanna V. The Effect of Flowable Composite Lining Thickness with Various Curing Techniques on Microleakage in Class II Composite Restorations: An in vitro Study. J Contemp Dent Pract 2013;14(1):56-60.


Author(s):  
CHARANTEJA VEMAGIRI ◽  
Uloopi KS ◽  
Vinay Chandrappa ◽  
Anusha Ch

Background: A successful restorative material forms a better adhesion, resist the microleakage and releases fluoride. However, existing glass ionomer cements cannot be used as a posterior restorative material in stress bearing areas. A new ionomer called Zirconomer, zirconia reinforced glass ionomer claims to exhibit high physical and biological properties. Aim: To assess and compare the microleakage, compressive strength, flexural strength and fluoride release from zirconomer with ketac silver. Materials & Methods: On twenty caries free premolar teeth (10 per each group), a class v cavity was restored with zirconomer and ketac silver. The microleakage was assessed using dye penetration test and stereomicroscope. The compressive and flexural strengths of these materials were measured using Instron Universal testing machine. The amount of fluoride released from the modified ionomers at pH 5 and pH 7 was estimated using Orion fluoride specific electrode. The obtained data was then subjected to statistical analysis. Results: Data was analysed using paired t-test for intergroup comparisons and unpaired t-test for intragroup comparisons. The overall microleakage (0.5±0.48) of zirconomer was significantly less (p=0.000) compared to ketac silver (1.9±0.83). Zirconomer demonstrated a significant higher compressive strength (330.25±60.14), flexural strength (33.058±2.36) than ketac silver (p= 0.000). Zirconomer demonstrated high fluoride release from day 1 to day 7 at both pH 5 and pH 7. Conclusion: Zirconomer demonstrated better physical and biological properties compared with ketac silver.


2017 ◽  
Vol 9 (1) ◽  
pp. 23-29
Author(s):  
Bijo Kurian

BACKGROUND AND OBJECTIVES: This study evaluated and compared the antimicrobial efficacy and minimal inhibitory concentration (MIC) of chlorhexidine 0.12% and extracts of aloe vera and mushroom against Streptococcus mutans and lactobacillus. MATERIALS & METHODOLOGY: The agar disc diffusion and broth micro dilution method was used to check the antimicrobial activity of 0.12% chlorhexidine and aqueous extracts of two medicinal plants. The test samples were divided as follows- Streptococcus mutans, group I: chlorhexidine, group II: Aloe vera and group III: Mushroom. Lactobacillus, Group I: chlorhexidine, group II: Aloe vera extract and group III: Mushroom extract. The zone of inhibition and MIC values were tabulated and the data was statistically analyzed using ANOVA and Bonferroni post- hoc tests. RESULTS: Chlorhexidine shows maximum antibacterial action against Streptococcus mutans and lactobacillus followed by mushroom extract and aloe veraextracts with the zone of inhibition of (20.3mm/ 24.13), (17.03/ 16.05), (14.09/14.26) respectively. Both the extracts had MIC value of 80µg/ ml and chlorhexidine was 40µg/ml. CONCLUSION: Within the limitations of this in- vitro study, it can be concluded that all the herbal extracts tested in this study demonstrated antibacterial activity against MS and lactobacillus. Chlorhexidine showed maximum antibacterial action against Streptococcus mutans and lactobacillus followed by mushroom extract and then aloe veraextracts with the zone of inhibition of (20.3mm/24.13), (17.03/ 16.05), (14.09/14.26) respectively. Herbal products have potent antimicrobial activity that can be looked at as an alternative to chlorhexidine. However, further in vitro and long-term in vivo studies are recommended to confirm and correlate the findings of this study clinically.


Sign in / Sign up

Export Citation Format

Share Document