Low-operating voltage-based piezoelectric ultrasonic actuator for tactile system applications

2021 ◽  
Vol 585 (1) ◽  
pp. 163-177
Author(s):  
Shalini Mukhopadhyay ◽  
Jayendra Kumar ◽  
Basudeba Behera
Author(s):  
Zhifeng Shao

Recently, low voltage (≤5kV) scanning electron microscopes have become popular because of their unprecedented advantages, such as minimized charging effects and smaller specimen damage, etc. Perhaps the most important advantage of LVSEM is that they may be able to provide ultrahigh resolution since the interaction volume decreases when electron energy is reduced. It is obvious that no matter how low the operating voltage is, the resolution is always poorer than the probe radius. To achieve 10Å resolution at 5kV (including non-local effects), we would require a probe radius of 5∽6 Å. At low voltages, we can no longer ignore the effects of chromatic aberration because of the increased ratio δV/V. The 3rd order spherical aberration is another major limiting factor. The optimized aperture should be calculated as


2019 ◽  
Vol 12 (1) ◽  
pp. 18-21
Author(s):  
V. A. Tikhonov

The influence of the periodicity of diagnostic measurements on the operational state of high-voltage transformers is considered. Examples of defects of switching devices of converter transformers and methods for their detection are given. The rationale for the importance of recognition of defects at an early stage of their occurrence is given. The influence of the multiplicity of overvoltages on the service life of converter transformers in the aluminum industry is investigated. Based on the analysis of the service life of converter transformers of one of the powerful aluminum plants, where 83% of converter transformers have exhausted their standard service life, it is shown that in 40% of cases it would be possible to avoid their failures, with timely detection and elimination of emerging defects. Examples of defects of OLR (on-load regulators) of converter transformers and methods for their detection are given. The importance of recognition of defects at an early stage of their occurrence is substantiated. A method for chromatographic analysis of dissolved gases in transformer oil has been developed for the qualitative determination of defects and ways to eliminate them. Examples of diagnostics of converter transformers at operating voltage and working load are given, providing the best quality operational characteristics of converter transformers. The periodicity of diagnostic measurements and the reduction of defects and failures has been substantiated. The question of diagnosing the state of the converter transformer TDNP-40000/10 at an enterprise of the aluminum industry is investigated. Currently, diagnostic methods are being developed based on chromatographic analysis of dissolved gases in transformer oil. The presented method of evaluating the operating parameters of transformers allows for the safe operation of high-voltage transformers and enables to increase the reliability of the power supply scheme of aluminum industry plants.


2018 ◽  
Author(s):  
T.A. Konev ◽  
V.A. Kuzmin ◽  
E. Yu. Mutovina ◽  
R.D. Puzhaykin ◽  
Vladimir Salomatov

Chemical sources of current are investigated as lines with distributed parameters. Analytical expressions are obtained for the voltage and active power values of the source at different distances from the beginning of the cell as well as dependences of the working voltage and active power on the source length. Effects of a reduction in the operating voltage and active power are due to the flow of electric current along the source during operation. The magnitude of these effects depends not only on the length of the source, but also on the ratio of characteristic resistance to the load resistance.<br>


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Jesuwanth Sugesh Ramesh Gabriel ◽  
Sivasubramanian Arunagiri

AbstractIn this paper, we report the performance of a carrier depletion Silicon PIN phase shifter with over layer of 130 nm. It is observed that an optimum intrinsic gap of 250 nm for a device length of 5 mm at 2 V, resulted in Extinction Ratio (ER) of 23.41 dB and Bit Error Rate (BER) of 1.00 × 10−7 is obtained for 50 Gbps. The phase shifter is also designed for length 2 mm with an intrinsic gap of 100 nm at an operating voltage <4 V. The study also reveals that the proposed design for Mach-Zehnder modulator operating at a data rate of 100 Gbps for the concentration of P = 7 × 1017 cm−3 and N = 5 × 1017 cm−3 gives better BER and phase performance. The proposed design was also analysed in an intra-data centre communication setup of fibre length 15 km.


Author(s):  
Yongseok Lee ◽  
Jung-Keun Yoo ◽  
Hyunyoung Park ◽  
Wonseok Ko ◽  
Jungmin Kang ◽  
...  

A nano-sized CuSO4/carbon (N-CSO/C) composite achieves outstanding electrochemical performances with a high average operating voltage of ∼2.8 V (vs. K+/K).


Electronics ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1212
Author(s):  
Kazuma Koketsu ◽  
Toru Tanzawa

This paper describes a charge pump system for a flexible thermoelectric generator (TEG). Even though the TEG has high-output impedance, the system controls the input voltage to keep it higher than the minimum operating voltage by modulating the input impedance of the charge pump using two-phase operation with low- and high-input impedance modes. The average input impedance can be matched with the output impedance of the TEG. How the system can be designed is also described in detail. A design demonstration was performed for the TEG with 400 Ω. The fabricated system was also measured with a flexible-type TEG based on carbon nanotubes. Even with an output impedance of 1.4 kΩ, the system converted thermal energy into electric power of 30 μW at 2.5 V to the following sensor ICs.


Sign in / Sign up

Export Citation Format

Share Document