Cross-sectional observation of resist patterns by focused ion beam etching

1993 ◽  
Vol 4 (3) ◽  
pp. 170-174 ◽  
Author(s):  
S Matsui
1990 ◽  
Vol 199 ◽  
Author(s):  
Kyung-ho Park

ABSTRACTA procedure for preparing cross-sectional TEM specimens by focused ion beam etching (FIB) of specific regions on an integrated circuit chip is outlined. The investigation of the morphology, structure and local chemistry of precisely selected regions of semiconductor devices becomes increasingly important since the lateral dimensions and layer thickness of device structures are continually being reduced. The standard technique of preparing specimens for TEM, whether planar or cross-sectional, cannot select particular small regions. Some techniques and a number of tools and fixtures have been proposed which allow us to prepare TEM specimen of prespecified locations in complex devices. Most of these techniques, however, are still very difficult, tedious process and time consuming.A new technique has been proposed recently involving the use of FIB. The technique ensures that the preselected area of submicron scale will be located in the electron transparent section used for TEM imaging, in preparation turn-around time of about two hours. The TEM imaging of specific contacts via hole in a VLSI chip is illustrated.


2004 ◽  
Vol 12 (1) ◽  
pp. 41-43
Author(s):  
Shane Roberts ◽  
Daniel Flatoff

Modern microelectronics have rapidly decreased in geometry to enhance the speed and processing power of computers. Advanced devices are approaching design rules of sub 0.13 micron in size, and the trend continues at the rate dictated by Moore's Law, Coupled with this reduction in device size, is a change in materials used for producing these devices. Traditional aluminum interconnect metallurgy and oxide dielectric materials are being replaced with copper and low-kmaterials in an effort to continue the trend of shrinking device sizes and higher processing capacities.These changes in materials and device sizes have provided the impetus for alternative methods for producing cross sections. Although focused ion beam instrumentation has been successfully used for preparing cross sections, a combinatorial approach using polishing and argon ion milling has been found to dramatically enhance the ability to produce high quality cross sectional samples in a reasonably short amount of time.


Author(s):  
N. Miura ◽  
K. Tsujimato ◽  
R. Kanehara ◽  
N. Tsutsui ◽  
S. Tsuji

Abstract This paper describes how faulty thin-film transistors (TFTs) having fragile structures in themselves can be characterized by cross-sectional transmission electron microscopy (X-TEM) through the achievement of pinpoint accuracy in focused ion beam (FIB) etching. We demonstrate X-TEM analysis for faulty TFTs caused by mechanical damages, microvoid in their multilayers and long aluminum whiskers growing from the electrodes. X-TEM specimen were prepared by FIB etching without losing unique structures owing to fragile locations. Cross-sectional bright-field TEM micrographs clearly showed the details of cross sectional structure of fragile location. This pin-point X-TEM is quite helpful to identify faults and to reveal root causes of failures.


2018 ◽  
Author(s):  
Sang Hoon Lee ◽  
Jeff Blackwood ◽  
Stacey Stone ◽  
Michael Schmidt ◽  
Mark Williamson ◽  
...  

Abstract The cross-sectional and planar analysis of current generation 3D device structures can be analyzed using a single Focused Ion Beam (FIB) mill. This is achieved using a diagonal milling technique that exposes a multilayer planar surface as well as the cross-section. this provides image data allowing for an efficient method to monitor the fabrication process and find device design errors. This process saves tremendous sample-to-data time, decreasing it from days to hours while still providing precise defect and structure data.


Author(s):  
Ching Shan Sung ◽  
Hsiu Ting Lee ◽  
Jian Shing Luo

Abstract Transmission electron microscopy (TEM) plays an important role in the structural analysis and characterization of materials for process evaluation and failure analysis in the integrated circuit (IC) industry as device shrinkage continues. It is well known that a high quality TEM sample is one of the keys which enables to facilitate successful TEM analysis. This paper demonstrates a few examples to show the tricks on positioning, protection deposition, sample dicing, and focused ion beam milling of the TEM sample preparation for advanced DRAMs. The micro-structures of the devices and samples architectures were observed by using cross sectional transmission electron microscopy, scanning electron microscopy, and optical microscopy. Following these tricks can help readers to prepare TEM samples with higher quality and efficiency.


Author(s):  
Chuan Zhang ◽  
Jane Y. Li ◽  
John Aguada ◽  
Howard Marks

Abstract This paper introduces a novel sample preparation method using plasma focused ion-beam (pFIB) milling at low grazing angle. Efficient and high precision preparation of site-specific cross-sectional samples with minimal alternation of device parameters can be achieved with this method. It offers the capability of acquiring a range of electrical characteristic signals from specific sites on the cross-section of devices, including imaging of junctions, Fins in the FinFETs and electrical probing of interconnect metal traces.


1998 ◽  
Vol 4 (S2) ◽  
pp. 860-861 ◽  
Author(s):  
A. Ramirez de Arellano López ◽  
W.-A. Chiou ◽  
K. T. Faber

The results of TEM analyses of materials are critically dependent on the quality of the sample prepared. Although numerous techniques have been developed in the last two decades, differential thinning of inhomogeneous materials remains a serious problem. Recently, focused ion beam (FIB) technique has been introduced for cross-sectional sample preparation for TEM and SEM.A novel system for depositing a fine-grain (∼ 200 nm) ceramic coating on a metal surface via a patent pending Small-Particle Plasma Spray (SPPS) technique has been developed at the Basic Industry Research Laboratory of Northwestern University. To understand the properties of the coated surface, the ceramic/metal interface and the microstructure of the ceramic coating must be investigated. This paper presents a comparison of the microstructure of an A12O3 coating on a mild steel substrate prepared using conventional and FEB techniques.


2021 ◽  
pp. 096739112110230
Author(s):  
Meltem Sezen ◽  
Busra Tugba Camic

The emphasis of biocompatible polymer applications in medical sciences and biotechnology has remarkably increased. Developing new low-cost, low-toxicity and lightweight composite forms of biopolymers has become even more attractive since the addition of new species into polymer matrices assist to improve biomedical activities of such materials to a higher extend. Developments in nanoscience and nanotechnology recently contribute to controlled fabrication and ultraprecise diagnosis of such materials. This study concerns the observation of solution processing effects in the fabrication of porous PLA/AGNWs bionanocomposite coatings using electron and ion processing based serial cross-sectioning and high-resolution imaging. The nanostructuring and characterization were both performed in a focused ion-beam-scanning electron microscope (FIB-SEM) platform. HR-SEM imaging was conducted on-site to track solvent based morphological property alterations of PLA and PLA/AgNWs structures. Simultaneous SEM-EDS analyses revealed the elemental distribution and the chemical composition along the cross-sectioned regions of the samples. Accordingly, it was observed that, in case of acetone dissolved materials, both pristine PLA and PLA/AgNWs samples sustained their foamy structure. When chloroform was used as the solvent, the porosity of the polymer matrices was less and the resulting structure was found to be denser than samples dissolved in acetone with a lower surface area ratio inside the material. This can be attributed to the rapid volatilization of acetone compared to chloroform, and hence the formation of interconnected pore network. For both nanocomposite biopolymers dissolved in acetone and chloroform, silver nanowires were homogeneously distributed throughout PLA matrices.


Sign in / Sign up

Export Citation Format

Share Document