scholarly journals Increase of Energy Efficiency of the Mechanical Ventilation System

Author(s):  
A I Sharapov ◽  
E Y Myakotina ◽  
Y V Shatskikh ◽  
A V Peshkova
Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 105
Author(s):  
Aldona Skotnicka-Siepsiak

In the present study, the real-world performance of a ground-to-air heat exchanger (GAHE) was analyzed in the Polish climate which is characterized by warm summers and cold winters. The heat exchanger’s performance was monitored over a period of three years (2017 to 2019), and real-world conditions were compared with a Typical Meteorological Year (TMY). The aim of the study was to assess the exchanger’s energy-efficiency potential in various ventilation scenarios in a single-family home under variable real-world conditions, rather than to simply determine its heating and cooling capacity. The analyzed single-family home was a modern, single-story building with a usable floor area of 115 m2. The building’s thermal insulation and airtightness met stringent energy-efficiency standards. Energy consumption in a building equipped with a natural ventilation system was compared with three other scenarios: ventilation coupled with a GAHE, mechanical ventilation with heat recovery and a high-efficiency heat exchanger (HE), and mechanical ventilation with heat recovery coupled with a GAHE. Sensible heating and cooling loads were calculated based on standard ISO 13790:2008, and latent heating and cooling loads were also included in the energy balance. During the year, the GAHE generated around 257.6 W of heating energy per hour and 124.7 W of cooling energy per hour. Presented results can be used to select the optimal HVAC system scenarios for engineering projects as well as private investors.


Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3008
Author(s):  
Agnieszka W. Lach ◽  
André V. Gaathaug

This paper presents a series of experiments on the effectiveness of existing mechanical ventilation systems during accidental hydrogen releases in confined spaces, such as underground garages. The purpose was to find the mass flow rate limit, hence the TPRD diameter limit, that will not require a change in the ventilation system. The experiments were performed in a 40 ft ISO container in Norway, and hydrogen gas was used in all experiments. The forced ventilation system was installed with a standard 315 mm diameter outlet. The ventilation parameters during the investigation were British Standard with 10 ACH and British Standard with 6 ACH. The hydrogen releases were obtained through 0.5 mm and 1 mm nozzles from different hydrogen reservoir pressures. Both types of mass flow, constant and blowdown, were included in the experimental matrix. The analysis of the hydrogen concentration of the created hydrogen cloud in the container shows the influence of the forced ventilation on hydrogen releases, together with TPRD diameter and reservoir pressure. The generated experimental data will be used to validate a CFD model in the next step.


2018 ◽  
Vol 196 ◽  
pp. 02007
Author(s):  
Arman Kostuganov ◽  
Yuri Vytchikov ◽  
Andrey Prilepskiy

The article describes development and application of self-contained ventilation systems in civil buildings. It suggests several models of air exchange within the building, compares these models and points out the variant of ventilating with self-contained mechanical systems with utilization of heat. The researchers conclude that structurally self-contained systems of mechanical ventilation with utilization of heat are most efficiently built into window constructions. This installation variant makes it possible to keep the interior, avoid building construction strengthening, shorten time and labor input of construction-assembling works, allow rational use of the vertical building envelopes area without extra space using. The paper key issue is the development of constructive solutions of self-contained ventilation systems main elements to ensure the possibility of their use in window structures. This research stage was developed with account of previous results of field tests and of such ventilation systems theoretical descriptions. The authors assess limit dimensions of the systems suitable for installment into window constructions of civil buildings in the view of modern Russian requirements to thermal protection. The research suggests a general constructive solution of such a ventilation system and a heat exchanger model which can be used as an air heat utilizer in these systems.


Complexity ◽  
2020 ◽  
Vol 2020 ◽  
pp. 1-15
Author(s):  
Liming Hao ◽  
Shuai Ren ◽  
Yan Shi ◽  
Na Wang ◽  
Yixuan Wang ◽  
...  

The synchrony of patient-ventilator interaction affects the process of mechanical ventilation which is clinically applied for respiratory support. The occurrence of patient-ventilator asynchrony (PVA) not only increases the risk of ventilator complications but also affects the comfort of patients. To solve the problem of uncertain patient-ventilator interaction in the mechanical ventilation system, a novel method to evaluate patient-ventilator synchrony is proposed in this article. Firstly, a pneumatic model is established to simulate the mechanical ventilation system, which is verified to be accurate by the experiments. Then, the PVA phenomena are classified and detected based on the analysis of the ventilator waveforms. On this basis, a novel synchrony index SIhao is established to evaluate the patient-ventilator synchrony. It not only solves the defects of previous evaluation indexes but also can be used as the response parameter in the future research of ventilator control algorithms. The accurate evaluation of patient-ventilator synchrony can be applied to the adjustment of clinical strategies and the pathological analyses of patients. This research can also reduce the burden on clinicians and help to realize the adaptive control of the mechanical ventilation and weaning process in the future.


Sign in / Sign up

Export Citation Format

Share Document