scholarly journals High-power short-duration radiofrequency ablation for atrial fibrillation

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
K Kassa ◽  
Z Nagy ◽  
B Kesoi ◽  
Z Som ◽  
C Foldesi ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction In recent times, high-power short-duration (HPSD) radiofrequency ablation (RFA) has emerged as an alternative strategy for pulmonary vein isolation (PVI) in atrial fibrillation (AF). Purpose We aimed to compare HPSD approach and conventional, ablation-index (AI) guided PVI using contact force sensing ablation catheters in respect of efficacy, safety, procedural characteristics, and outcome. Methods A total of 184 consecutive AF patients with first PVI were enrolled (age: 60 ± 11 years, paroxysmal: 56.5%, persistent: 43.5%) between November 2016 and December 2019. An ablation protocol of 50W energy with 15-20 g contact force was used for a duration of 8-12 sec based on the loss of capture concept in the HPSD group (n = 91) meanwhile, PVI was achieved according to the conventional power settings (posterior wall 25W, AI: 400, anterior wall 35W, AI: 550 ) in the control group (n = 93). During 1-year follow-up, documented AF for more than 30 seconds was considered as recurrence. Results Radiofrequency time and procedural time were significantly shorter using HPSD ablation (26.0 ± 12.7 min vs. 42.9 ± 12.6 min, p < 0.001, and 91 ± 30.1 min vs. 105.3 ± 28 min, p < 0.001). The HPSD strategy significantly lowered fluoroscopy time and radiation dose (5.47 ± 4.07 min vs. 8.15 ± 10.04 min, p = 0.019, and 430.2 ± 534.06 cGycm2 vs. 604.2 ± 633.9 cGycm2, p = 0.046). The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 76.9% of patients free from AF compared to 66.7% in the control group (p = 0.037). No pericardial tamponade, periprocedural thromboembolic complication, or atrio-oesophageal fistula occurred in the HPSD group. We observed 2 pericardial tamponade and 1 periprocedural stroke in the control group. Conclusions HPSD RFA for AF was demonstrated to be safe, and lead to significantly improved 1-year outcome in our mixed patient population. HPSD protocol significantly shortened procedural and radiofrequency time with decreased fluoroscopy time and radiation exposure.

Heart Rhythm ◽  
2020 ◽  
Vol 17 (8) ◽  
pp. 1223-1231 ◽  
Author(s):  
Roger A. Winkle ◽  
R. Hardwin Mead ◽  
Gregory Engel ◽  
Melissa H. Kong ◽  
Jonathan Salcedo ◽  
...  

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Chun-Chao Chen ◽  
Po-Tseng Lee ◽  
Vu Van Ba ◽  
Chieh-Mao Chuang ◽  
Yenn-Jiang Lin ◽  
...  

Abstract Background Transmural lesion creation is essential for effective atrial fibrillation (AF) ablation. Lesion characteristics between conventional energy and high-power short-duration (HPSD) setting in contact force-guided (CF) ablation for AF remained unclear. Methods Eighty consecutive AF patients who received CF with conventional energy setting (power control: 25–30 W, force–time integral = 400 g s, n = 40) or with HPSD (power control: 40–50 W, 10 s, n = 40) ablation were analyzed. Of them, 15 patients in each conventional and HPSD group were matched by age and gender respectively for ablation lesions analysis. Type A and B lesions were defined as a lesion with and without significant voltage reduction after ablation, respectively. The anatomical distribution of these lesions and ablation outcomes among the 2 groups were analyzed. Results 1615 and 1724 ablation lesions were analyzed in the conventional and HPSD groups, respectively. HPSD group had a higher proportion of type A lesion compared to conventional group (P < 0.01). In the conventional group, most type A lesions were at the right pulmonary vein (RPV) posterior wall (50.2%) whereas in the HPSD group, most type A lesions were at the RPV anterior wall (44.0%) (P = 0.04). The procedure time and ablation time were significantly shorter in the HPSD group than that in the conventional group (91.0 ± 12.1 vs. 124 ± 14.2 min, P = 0.03; 30.7 ± 19.2 vs. 57.8 ± 21 min, P = 0.02, respectively). At a mean follow-up period of 11 ± 1.4 months, there were 13 and 7 patients with recurrence in conventional and HPSD group respectively (P = 0.03). Conclusion Optimal ablation lesion characteristics and distribution after conventional and HPSD ablation differed significantly. HPSD ablation had shorter ablation time and lower recurrence rate than did conventional ablation.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Ali H. Hachem ◽  
Joseph E. Marine ◽  
Housam A. Tahboub ◽  
Sana Kamdar ◽  
Shaffi Kanjwal ◽  
...  

Background. Pulmonary vein isolation is commonly performed using radiofrequency energy with cryoablation gaining acceptance. We performed a meta-analysis of randomized controlled trials which compared radiofrequency versus cryoablation for patients with atrial fibrillation. Methods. A systematic search strategy identified both published and unpublished articles from inception to November 10, 2016, in multiple databases. The primary outcomes for this meta-analysis were long-term freedom from atrial fibrillation at 12-month follow-up and overall postoperative complication rates. For all included studies, the methodological quality was assessed through the Cochrane Collaboration’s tool for risk of bias. Results. A total of 247 articles were identified with eight being included in this review as they satisfied the prespecified inclusion criteria. Overall, there was no significant difference in freedom from atrial fibrillation at ≥12-month follow-up between those receiving cryoballoon and radiofrequency ablation, respectively (OR = 0.98, CI = 0.67–1.43, I2 = 56%, p=0.90). Additionally, the secondary outcomes of duration of ablation, fluoroscopy time, and ablation time failed to reach significance. Cryoballoon ablation had significantly greater odds of postoperative phrenic nerve injury at 12-month follow-up. Conclusions. Our meta-analysis suggests that cryoballoon ablation provides comparable benefits with regard to freedom from atrial fibrillation at medium-term follow-up, fluoroscopy time, ablation time, operative duration, and overall complication rate in comparison to radiofrequency ablation.


EP Europace ◽  
2020 ◽  
Vol 22 (10) ◽  
pp. 1487-1494 ◽  
Author(s):  
Katharina Schoene ◽  
Arash Arya ◽  
Friederike Grashoff ◽  
Helge Knopp ◽  
Alexander Weber ◽  
...  

Abstract Aims The aim of the study was to determine the incidence of oesophageal lesions after radiofrequency ablation (RFA) of atrial fibrillation (AF) with or without the use of oesophageal temperature probes. Methods and results Two hundred patients were prospectively randomized into two groups: the OPERA+ group underwent RFA using oesophageal probes (SensiTherm™); the OPERA− group received RFA using fixed energy levels of 25 W at the posterior wall without an oesophageal probe. All patients underwent post-interventional endoscopy and Holter-electrocardiogram after 6 months. (Clinical.Trials.gov: NCT03246594). One hundred patients were randomized in OPERA+ and 100 patients in OPERA−. The drop-out rate was 10%. In total, 18/180 (10%) patients developed endoscopically diagnosed oesophageal lesions (EDEL). There was no difference between the groups with 10/90 (11%) EDEL in OPERA+ vs. 8/90 (9%) in OPERA− (P = 0.62). Despite the higher power delivered at the posterior wall in OPERA+ [28 ± 4 vs. 25 ± 2 W (P = 0.001)], the average EDEL size was equal [5.7 ± 2.6 vs. 4.5 ± 1.7 mm (P = 0.38)]. The peak temperature did not correlate with EDEL size. During follow-up, no patient died. Only one patient in OPERA− required a specific therapy for treatment of the lesion. Cumulative AF recurrence after 6 (3–13) months was 28/87 (32%) vs. 34/88 (39%), P = 0.541. Conclusion This first randomized study demonstrates that intraoesophageal temperature monitoring using the SensiTherm™ probe does not affect the probability of developing EDEL. The peak temperature measured by the thermoprobe seems not to correlate with the incidence of EDEL. Empiric energy reduction at the posterior wall did not affect the efficacy of the procedure.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
D De Campos ◽  
L Puga ◽  
P Sousa ◽  
N Antonio ◽  
L Elvas

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Ablation Index (AI) software has been associated with better freedom from atrial arrhythmias after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF). There is conflicting data regarding the relationship between high sensitivity cardiac Troponin I (Hs-cTnI) and arrhythmia recurrence. The objective was to evaluate the impact of AI on Hs-cTnI level and on ablation effectiveness quotient (AEQ) and to assess if these markers are predictors of arrhythmia recurrence.  Methods Prospective observational study of consecutive patients referred for PVI for paroxysmal AF ablation from October 2017 to June 2018 according to a pre-specified AI protocol. Procedural endpoints and 2-year follow-up outcomes were assessed and compared to a retrospective cohort of conventional PVI contact-force-guided group .  Results A total of 56 patients were included: 29 patients the AI group and 27 patients in the control group. The mean age was 60.5 ± 10.3 years, 48% males. Left ventricular ejection fraction (60 ± 6 % AI vs 61 ± 5 % control, P = 0.07) and left atrium diameter (43 ± 7 mm AI vs 44 ± 6 mm control, P = 0.58) were comparable between groups. First-pass isolation was shown to be higher in the AI group (79% AI vs 44%, p= 0.01). Mean number of radiofrequency applications was lower in the AI group (93 ± 24 vs 111 ± 30, P = 0.02). Average contact-force was similar between groups (17.6 ± 4.1 g vs 22.6 ± 10.7 g, P =0.166). Patients that performed PVI guided by the AI had lower Hs-cTnI (1815 ± 1146 ng/L vs 3274 ± 1696 ng/L, p &lt; 0.001) and lower AEQ (1.01 ± 0.7 ng/L/s vs 1.51 ± 0.7 ng/L/s, P = 0.011) compared to patients in the control group. During a mean follow-up of 26 ± 11 months, AF recurrence was documented in 10.3% of patients in the AI group and 22.2% in the control group (P = 0.223). Neither Hs-cTnI nor AEQ levels were predictors of arrhythmia recurrence.  Conclusions These data suggest that AI-guided catheter ablation is associated with reduced levels of of Hs-cTnI and AEQ. Neither Hs-cTnI and AEQ should be used to predict arrhythmia recurrence. Abstract Figure.


Author(s):  
oluwaseun adeola ◽  
asad Al Aboud ◽  
Travis Richardson ◽  
Gregory Michaud

Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF) However AF recurrence after a single ablation procedure is common and often attributed to ineffective lesion delivery during PVI. In this issue of the Journal of Cardiovascular Electrophysiology, Chen et al reported their experience with 122 patients who underwent an ablation index-high power (AI-HP) strategy RF ablation for AF using 50W power, targeting AI values of 550 on the anterior left atrium (LA), 400 on the posterior wall and inter-lesion distance (ILD) 6mm. They achieved 1st pass PVI in 96.7% of cases, mean RF time was 11.5min and total procedure time was only 55.8min. All patients had 72h-Holter monitor and trans-telephonic follow up. They reported 89.4% arrhythmia free survival among patients with paroxysmal AF and 80.4% among patients with persistent AF at 15-month follow up. Sixty (49%) patients had luminal esophageal temperature (LET) >390C out of which 3 (2.5%) had asymptomatic endoscopic esophageal erosions/erythema. Four (3%) patients had clinically apparent steam pops during ablation with no adverse clinical sequela. While AI-HP guided RF ablation may be an attractive strategy for PVI that likely reduces procedure times and probably has comparable efficacy to conventional ablation settings, its safety requires further evaluation. Feedback from the ablated tissue may need to be incorporated into optimized ablation energy parameters to further improve outcomes.


2021 ◽  
Author(s):  
Fabricio Sarmento Vassallo ◽  
Lucas Luis Meigre ◽  
Eduardo Giestas Serpa ◽  
Christiano Lemos da Cunha ◽  
Aloyr Gonçalves Simões Jr. ◽  
...  

EP Europace ◽  
2019 ◽  
Vol 22 (3) ◽  
pp. 388-393 ◽  
Author(s):  
Marc Kottmaier ◽  
Miruna Popa ◽  
Felix Bourier ◽  
Tilko Reents ◽  
Jairo Cifuentes ◽  
...  

Abstract Aims Pulmonary vein isolation (PVI) using radiofrequency ablation (RFA) in patients with paroxysmal atrial fibrillation (PAF) is effective but hampered by pulmonary vein reconnection due to insufficient ablation lesions. High-power delivery over a short period of time (HPSD) in RFA is stated to create more efficient lesions. The aim of this study was to compare intraprocedural safety and outcome of HPSD ablation to conventional power settings in patients undergoing PVI for PAF. Methods and results We included 197 patients with PAF that were scheduled for PVI. An ablation protocol with 70 W and a duration cut-off of 7 s at the anterior left atrium (LA) and 5 s at the posterior LA (HPSD group; n = 97) was compared to a conventional power protocol with 30–40 W for 20–40 s (standard group; n = 100) in terms of periprocedural complications and a 1-year outcome. The HPSD group showed significantly less arrhythmia recurrence during 1-year follow-up with 83.1% of patients free from atrial fibrillation compared to 65.1% in the standard group (P &lt; 0.013). No pericardial tamponade, periprocedural thromboembolic complications, or atrio-oesophageal fistula occurred in either group. Mean radiofrequency time (12.4 ± 3.4 min vs. 35.6 ± 12.1 min) and procedural time (89.5 ± 23.9 min vs. 111.15 ± 27.9 min) were significantly shorter in the HPSD group compared to the standard group (both P &lt; 0.001). Conclusion High-power short-duration ablation demonstrated a comparable safety profile to conventional ablation. High-power short-duration ablation using 70 W for 5–7 s leads to significantly less arrhythmia recurrences after 1 year. Radiofrequency and procedural time were significantly shortened.


2022 ◽  
Vol 38 (3) ◽  
Author(s):  
Xiaoru Qin ◽  
Xiaofei Jiang ◽  
Qiyan Yuan ◽  
Guangli Xu ◽  
Xianzhi He

Objective: To explore the optimal ablation index (AI) parameters for radiofrequency catheter ablation (RA) for treating atrial fibrillation (AF). Method: Patients with AF (186) who underwent bilateral PVAI in the Department of Cardiology, Zhuhai People’s Hospital, Guangdong Province, from March 2018 to October 2019 and received catheter ablation as first-round treatment, were grouped according to the received AI. Control group included patients (95) who received the recommended AI ablation (350–400 for posterior wall, 400–450 for non-posterior wall). Patients in optimal AI group were ablated with optimal AI (300–330 for posterior wall, 350–380 for non-posterior wall). Results: Of 186 patients, 66 patients had paroxysmal atrial fibrillation and a mean CHA2DS2-VASc score of 2.83±1.64. Isolation rates of bilateral PVI in both groups were 91.4% and 93.6%, for patients with paroxysmal atrial fibrillation, and 81.7% and 80% for patients with persistent atrial fibrillation (P > 0.05). Left atrial function index (LAFI) decreased under the condition of sinus rhythm at the 3rd and 6th months (P < 0.05). LAFI improvement was significantly better in the optimal AI group than in the control group (P < 0.05). Rates of pain and cough during the ablation, and postoperative gastrointestinal discomfort and use of PPIs were higher in the control group (P < 0.05). Conclusion: Radiofrequency ablation of AF, guided by optimal AI combined with impedance, can minimize atrial injury, prevent atrial failure, promote the recovery of atrial function, reduces intraoperative cough, pain, and postoperative gastrointestinal discomfort and use of PPIs. doi: https://doi.org/10.12669/pjms.38.3.4971 How to cite this:Qin X, Jiang X, Yuan Q, Xu G, He X. Optimal ablation index parameters for radiofrequency ablation therapy of atrial fibrillation. Pak J Med Sci. 2022;38(3):---------. doi: https://doi.org/10.12669/pjms.38.3.4971 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Sign in / Sign up

Export Citation Format

Share Document