Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry

EP Europace ◽  
2019 ◽  
Vol 21 (12) ◽  
pp. 1876-1889 ◽  
Author(s):  
Eyal Nof ◽  
Maria Grazia Bongiorni ◽  
Angelo Auricchio ◽  
Christian Butter ◽  
Nikolaos Dagres ◽  
...  

Abstract Aims The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved. Methods and results ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08–1.19), P < 0.0001 and OR 2.68 (1.22–5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04–0.95), P = 0.03 and OR 0.32 (0.13–0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01–4.16), P = 0.046]. Conclusion A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.

Author(s):  
Sing-Chien Yap ◽  
Rohit E. Bhagwandien ◽  
Dominic A. M. J. Theuns ◽  
Yunus Emre Yasar ◽  
John de Heide ◽  
...  

Abstract Purpose During transvenous lead extraction (TLE), the femoral snare has mainly been used as a bail-out procedure. The purpose of the present study is to evaluate the efficacy and safety of a TLE approach with a low threshold to use a combined superior and femoral approach. Methods This is a single-center observational study including all TLE procedures between 2012 till 2019. Results A total of 264 procedures (median age 63 (51–71) years, 67.0% male) were performed in the study period. The main indications for TLE were lead malfunction (67.0%), isolated pocket infection (17.0%) and systemic infection (11.7%). The median dwelling time of the oldest targeted lead was 6.8 (4.0–9.7) years. The techniques used to perform the procedure were the use of a femoral snare only (30%), combined rotational powered sheath and femoral snare (25%), manual traction only (20%), rotational powered sheath only (17%) and locking stylet only (8%). The complete and clinical procedural success rate was 90.2% and 97.7%, respectively, and complete lead removal rate was 94.1% of all targeted leads. The major and minor procedure-related complication rates were 1.1% and 10.2%, respectively. There was one case (0.4%) of emergent sternotomy for management of cardiac avulsion. Furthermore, there were 5 in-hospital non-procedure-related deaths (1.9%), of whom 4 were related to septic shock due to a Staphylococcus aureus endocarditis after an uncomplicated TLE with complete removal of all leads. Conclusion An effective and safe TLE procedure can be achieved by using the synergy between a superior and femoral approach.


Author(s):  
Kevin Fitzmartin ◽  
Aalok Kacha

Cardiac implantable electronic devices (CIEDs) are used for an increasing range of indications. With a broader range of indications, CIEDs are being implanted in increasing numbers. They are being used in older patients as well as patients with more comorbidities. As expected with these trends, the need for device extraction for a variety of reasons has steadily grown as well. These leads can often be removed via simple traction, but other techniques have been developed for circumstances where removal is more complex. To perform this procedure safely, a team-based approach is required, as is the ability to anticipate consequences of complications for each of the different methods of removal. A gold standard method has not been identified for transvenous lead extraction, but rather one has a toolbox of methods at their disposal. In this chapter, indications for lead removal, extraction techniques and devices, as well as potential complications are reviewed.


2019 ◽  
Vol 7 (15) ◽  
pp. 2447-2451
Author(s):  
Ibrahim El-Zoghby ◽  
Amr Nawar ◽  
Mohamed Soliman ◽  
Mahmoud Kenawy ◽  
Khaled Hussien ◽  
...  

BACKGROUND: The growing needs to extract cardiovascular implantable electronic devices warrants the need to improve the outcome and prevent complications. AIM: This study aims to analyse the findings and identify factors associated with complications of Percutaneous Transvenous Lead Extraction in the Critical Care Department, Cairo University. METHODS: We studied 52 candidates for Percutaneous Transvenous Lead extraction of a Permanent Pace Maker (PPM) regarding extraction indications, comorbidities, device type, complications and outcome. Extraction was first attempted by simple manual traction using regular non-locking stylet and if failed, locking stylet, and evolution dilator sheath were used. RESULTS: We extracted 110 leads with a mean lead age of 4.67 ± 3.6 years. The most common extraction indication was an infection (71.15%). Indications correlated significantly with comorbidities (p = 0.024), the most common being Diabetes Mellitus (40.38%). Simple traction was successful in 31 % of the leads, while 69% were extracted using locking stylet and evolution dilator sheath. The method of lead extraction correlated significantly with lead age (P ≤ 0.001). Complications were significantly higher with extraction by evolution dilator sheaths than by simple traction (P = 0.003) and in older patients (P = 0.008). Complications also correlated significantly with extractions indications (p = 0.012), type of PPM (P = 0.037), number of extracted leads (P = 0.041), and lead age (p= 0.011). CONCLUSION: Among the studied variables, extraction indications particularly infection, was the only preventable factor significantly associated with complications. While focusing on preventable factors, improving, implantation and extraction techniques should also be addressed.


2019 ◽  
Vol 2019 ◽  
pp. 1-4
Author(s):  
Caleb Norton ◽  
Benjamin Holmes ◽  
Asad Al Aboud ◽  
Eun-Jeong Kim ◽  
Holly Gonzales ◽  
...  

There is an increasing prevalence of cardiac implantable electronic devices (CIEDs) due to expanding adoption and availability of these evidence-based therapies. With the increased prevalence of these life-saving devices, there has also been an increased demand for lead removal and lead extraction. Understanding the specific subgroups of patients at high risk for complications during and after lead extraction has become imperative to properly manage endovascular CIED leads. There have been multiple published studies describing clinical variables that predict adverse outcomes in CIED system extractions; however, the risk of complications in leads placed after cardiac transplantation has not specifically been addressed to date. We present four cases of transvenous extraction and removal of pacing leads placed after cardiac transplantation. There were no major complications related to extraction in these four cases; however, three of the four patients died within one year after the procedure. While the etiology of death in these cases seemed to be unrelated to the extraction procedure, the indications for extraction (infection in the setting of immunosuppression and calcineurin-associated ESRD and poor sensing/capture possibly secondary to chronic rejection and/or frequent right heart biopsies) likely contributed at least indirectly to the subsequent death.


2019 ◽  
Vol 14 (9-10) ◽  
pp. 240-240
Author(s):  
Richard Matasić ◽  
Ivica Šafradin ◽  
Danijela Krnjić ◽  
Dubravka Milača ◽  
Davor Radić

Medicina ◽  
2019 ◽  
Vol 55 (9) ◽  
pp. 566
Author(s):  
Nesterovics ◽  
Nesterovics ◽  
Stradins ◽  
Kalejs ◽  
Ansabergs ◽  
...  

Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE and their antimicrobial resistance and to identify possible risk factors of patients who present with LRIE. Materials and Methods: The study was performed retrospectively at Pauls Stradins Clinical University Hospital (PSCUH). The study included patients who were referred to PSCUH due to LRIE for lead extraction. Patients were identified from procedural journals. Information about isolated microorganisms, patient comorbidities and visual diagnostics data was taken from patient records. Results: Forty-nine patients with CIED related infective endocarditis were included in the study, 34 (69.4%) were male, median age of all patients was 65.0 (50.5–73.0) years, median hospital stay was 15.5 (22.0–30.5) days. Successful and complete lead extraction was achieved in all patients. Thirty-two (65.3%) had received antibiotics prior to blood sample. Only in 31 (63.3%) positive culture results were seen. The most common isolated pathogens were Staphylococcus aureus (23.5%) and coagulase negative staphylococci (23.5%). Other bacteria were isolated considerably less often. The atrial lead was most common location for lead vegetations, seen in 50.0% of cases. Five (10.2%) patients have died due to the disease. Conclusions: Lead-related infective endocarditis is a major complication of cardiac implantable electronic devices with considerable morbidity and mortality, which in our study was as high as 10.2%.