scholarly journals Calculation of matrix permeability from velocity and attenuation of ultrasonic S-wave

2021 ◽  
Vol 18 (6) ◽  
pp. 984-994
Author(s):  
Guangquan Li ◽  
Chaodi Xie

Abstract Previously, hydrogeologists and petroleum engineers use seepage experiments to measure permeability. This paper develops a novel method to calculate matrix permeability from velocity and attenuation of an ultrasonic S-wave. At first, permeability is derived as a function of frequency when an S-wave scans a fluid-saturated rock. Substituting the permeability into a previous S-wave model gives theoretical velocity and attenuation, in which the nexus parameter is the average distance of aperture representing pores. Fitting the predicted velocity and quality factor against the measured counterparts yields permeability in the full frequency range. For Berea sandstone, the inverted permeability at low frequency (0.0376 Darcy) is comparable to Darcy permeability (0.075 Darcy), confirming that Berea sandstone is homogenous. For Boise sandstone, the inverted permeability at low frequency is 0.0457 Darcy, much lower than Darcy permeability (1 Darcy). When S-wave scans the rocks, its velocity and attenuation are dominated by matrix pore throats and the inverted permeability represents matrix permeability. Unlike Berea sandstone, Boise sandstone has fractures and widely distributed grain diameters. The fractures and the large pores (due to large grain diameter) are preferential pathways that increase Darcy permeability far more than matrix permeability.

Author(s):  
Martijn P. C. de Jong ◽  
Mart Borsboom ◽  
Jan A. M. de Bont ◽  
Bas van Vossen

The motions of (LNG) vessels moored offshore at depths ranging from about 20 to 100 m may depend significantly on the presence of (bound) low-frequency waves with periods in the order of 100 s. This is because these moored vessels show a large motion response in this frequency range and because the energy contents of low-frequency waves at these ‘intermediate’ depths is relatively large. As part of the Joint Industry Project HawaI, the operational Boussinesq-type wave model of Deltares, TRITON, was used to investigate whether this type of wave models could predict bound low-frequency waves (setdown waves) at intermediate depths. Comparison to measured and theoretical data, however, showed an underestimation of the computed levels of bound low-frequency wave heights for this depth range by a factor 2 to 4. Recently, additional tests were made with TRITON in situations for which the model has been designed: coastal engineering applications in shallow water (depths up to at most 20 m). These also showed an underestimation of the bound low-frequency wave heights, albeit smaller, up to a factor 2. In view of the importance of the energy contained in the low-frequency range for certain nearshore and shoreline processes, such as morphological processes, this underestimation is also of concern in coastal engineering. This triggered the development of a higher-order extension of the TRITON model equations (Borsboom, 2008, Wellens, 2010), with the aim to improve the accuracy of the model for long waves while still keeping computational times within acceptable (operational) limits. This paper reports on the usefulness of the extended model for the field of application considered in JIP HawaI/II: providing wave data for calculating the motions of vessels moored in intermediate depths. The results show a significant improvement of the modeling of nonlinear wave dynamics, including the prediction of bound low-frequency waves. This means that the model extension is an important step towards an operational Boussinesq-type wave model with sufficient accuracy in both the wave-frequency (sea, swell) and the low-frequency range for applications in intermediate depths.


Geophysics ◽  
1986 ◽  
Vol 51 (1) ◽  
pp. 183-189 ◽  
Author(s):  
Kenneth W. Winkler

It is generally accepted that acoustic velocities in fluid‐saturated rocks vary with frequency. Evidence comes from experimental measurements and from theoretical causality arguments. We have developed a simple analysis technique that gives estimates of total velocity dispersion between zero frequency and any measurement frequency. The technique requires compressional (P) and shear (S) wave velocity measurements on dry and fully saturated rock. Assuming that the dry velocities are independent of frequency, the Biot‐Gassmann equations are used to calculate the zero‐frequency velocities in the fully saturated rock. Any difference between the measured velocities and the calculated zero‐frequency velocities is interpreted as evidence of dispersion. Application of this analysis technique to a variety c ultrasonic data sets gives consistent results. In many rocks, dispersion between zero frequency and ultrasonic frequencies is on the order of 10 percent at low effective stress, and it decreases to only a few percent at higher stresses. Dispersion varies with degree of saturation and with fluid viscosity in the same way as do low‐frequency attenuation measurements. The results are readily interpreted in terms of the same local‐flow absorption/dispersion mechanism that has been used to explain recent laboratory attenuation measurements. This apparent dispersion places upper bounds on seismic‐to‐sonic velocity differences. It also points out possible discrepancies between seismic velocities and ultrasonic laboratory measurements.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


2001 ◽  
Vol 29 (4) ◽  
pp. 258-268 ◽  
Author(s):  
G. Jianmin ◽  
R. Gall ◽  
W. Zuomin

Abstract A variable parameter model to study dynamic tire responses is presented. A modified device to measure terrain roughness is used to measure dynamic damping and stiffness characteristics of rolling tires. The device was used to examine the dynamic behavior of a tire in the speed range from 0 to 10 km/h. The inflation pressure during the tests was adjusted to 160, 240, and 320 kPa. The vertical load was 5.2 kN. The results indicate that the damping and stiffness decrease with velocity. Regression formulas for the non-linear experimental damping and stiffness are obtained. These results can be used as input parameters for vehicle simulation to evaluate the vehicle's driving and comfort performance in the medium-low frequency range (0–100 Hz). This way it can be important for tire design and the forecasting of the dynamic behavior of tires.


2021 ◽  
Vol 11 (4) ◽  
pp. 1932
Author(s):  
Weixuan Wang ◽  
Qinyan Xing ◽  
Qinghao Yang

Based on the newly proposed generalized Galerkin weak form (GGW) method, a two-step time integration method with controllable numerical dissipation is presented. In the first sub-step, the GGW method is used, and in the second sub-step, a new parameter is introduced by using the idea of a trapezoidal integral. According to the numerical analysis, it can be concluded that this method is unconditionally stable and its numerical damping is controllable with the change in introduced parameters. Compared with the GGW method, this two-step scheme avoids the fast numerical dissipation in a low-frequency range. To highlight the performance of the proposed method, some numerical problems are presented and illustrated which show that this method possesses superior accuracy, stability and efficiency compared with conventional trapezoidal rule, the Wilson method, and the Bathe method. High accuracy in a low-frequency range and controllable numerical dissipation in a high-frequency range are both the merits of the method.


Foods ◽  
2019 ◽  
Vol 8 (11) ◽  
pp. 534 ◽  
Author(s):  
Line Elgaard ◽  
Line A. Mielby ◽  
Helene Hopfer ◽  
Derek V. Byrne

Feedback on panel performance is traditionally provided by the panel leader, following an evaluation session. However, a novel method for providing immediate feedback to panelists was proposed, the Feedback Calibration Method (FCM). The aim of the current study was to compare the performance of two panels trained by using FCM with two different approaches for ranges calibration, namely self-calibrated and fixed ranges. Both panels were trained using FCM for nine one-hour sessions, followed by a sensory evaluation of five beer samples (in replicates). Results showed no difference in sample positioning in the sensory space by the two panels. Furthermore, the panels’ discriminability was also similar, while the self-calibrated panel had the highest repeatability. The results from the average distance from target and standard deviations showed that the self-calibrated panel had the lowest distance from target and standard deviation throughout all sessions. However, the decrease in average distance from target and standard deviations over training sessions was similar among panels, meaning that the increase in performance was similar. The fact that both panels had a similar increase in performance and yielded similar sensory profiles indicates that the choice of target value calibration method is unimportant. However, the use of self-calibrated ranges could introduce an issue with the progression of the target scores over session, which is why the fixed target ranges should be applied, if available.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Magdalena Janc ◽  
Mariola Sliwinska-Kowalska ◽  
Piotr Politanski ◽  
Marek Kaminski ◽  
Magdalena Jozefowicz-Korczynska ◽  
...  

AbstractThe aim of our study was to validate the method of head-shake static posturography (HS-posturography) in healthy individuals and to establish the value of this novel method in the diagnostics of patients with unilateral vestibular lesion (UV). The study included 202 participants divided into two groups, one consisting of 133 patients with canal paresis CP > 19% and one of 69 healthy subjects. Participant was tested according to the standard protocol of static posturography (SP), and with head movements of 0.3 Hz (HS 40), 0.6 Hz (HS 70) in random order controlled by a metronome. HS-posturography revealed a similar repeatability and internal consistency as the standard posturography. In patients with UV, 4th condition revealed higher sensitivity (74%) and specificity (71%) in HS 40 than in the standard posturography (67%, 65% respectively) and HS 70 (54%, 70% respectively). Static posturography and HS- posturography revealed a high reliability of the testing method. The head movements added to static posturography improve the sensitivity and specificity of the method in group with vestibular impairment. The most important test for that purpose seems to be the one on unstable surface with the eyes closed, with low frequency of head movements.


Geophysics ◽  
1992 ◽  
Vol 57 (6) ◽  
pp. 854-859 ◽  
Author(s):  
Xiao Ming Tang

A new technique for measuring elastic wave attenuation in the frequency range of 10–150 kHz consists of measuring low‐frequency waveforms using two cylindrical bars of the same material but of different lengths. The attenuation is obtained through two steps. In the first, the waveform measured within the shorter bar is propagated to the length of the longer bar, and the distortion of the waveform due to the dispersion effect of the cylindrical waveguide is compensated. The second step is the inversion for the attenuation or Q of the bar material by minimizing the difference between the waveform propagated from the shorter bar and the waveform measured within the longer bar. The waveform inversion is performed in the time domain, and the waveforms can be appropriately truncated to avoid multiple reflections due to the finite size of the (shorter) sample, allowing attenuation to be measured at long wavelengths or low frequencies. The frequency range in which this technique operates fills the gap between the resonant bar measurement (∼10 kHz) and ultrasonic measurement (∼100–1000 kHz). By using the technique, attenuation values in a PVC (a highly attenuative) material and in Sierra White granite were measured in the frequency range of 40–140 kHz. The obtained attenuation values for the two materials are found to be reliable and consistent.


Sign in / Sign up

Export Citation Format

Share Document