A New Method of Increasing the Measurement Accuracy in Adaptive Measurement Systems with Bank of Sensors

Author(s):  
Konrad Jedrzejewski
2021 ◽  
Vol 11 (13) ◽  
pp. 5787
Author(s):  
Toan-Thang Vu ◽  
Thanh-Tung Vu ◽  
Van-Doanh Tran ◽  
Thanh-Dong Nguyen ◽  
Ngoc-Tam Bui

The measurement speed and measurement accuracy of a displacement measuring interferometer are key parameters. To verify these parameters, a fast and high-accuracy motion is required. However, the displacement induced by a mechanical actuator generates disadvantageous features, such as slow motion, hysteresis, distortion, and vibration. This paper proposes a new method for a nonmechanical high-speed motion using an electro-optic modulator (EOM). The method is based on the principle that all displacement measuring interferometers measure the phase change to calculate the displacement. This means that the EOM can be used to accurately generate phase change rather than a mechanical actuator. The proposed method is then validated by placing the EOM into an arm of a frequency modulation interferometer. By using two lock-in amplifiers, the phase change in an EOM and, hence, the corresponding virtual displacement could be measured by the interferometer. The measurement showed that the system could achieve a displacement at 20 kHz, a speed of 6.08 mm/s, and a displacement noise level < 100 pm//√Hz above 2 kHz. The proposed virtual displacement can be applied to determine both the measurement speed and accuracy of displacement measuring interferometers, such as homodyne interferometers, heterodyne interferometers, and frequency modulated interferometers.


1997 ◽  
Vol 119 (2) ◽  
pp. 236-242 ◽  
Author(s):  
K. Peleg

The classical calibration problem is primarily concerned with comparing an approximate measurement method with a very precise one. Frequently, both measurement methods are very noisy, so we cannot regard either method as giving the true value of the quantity being measured. Sometimes, it is desired to replace a destructive or slow measurement method, by a noninvasive, faster or less expensive one. The simplest solution is to cross calibrate one measurement method in terms of the other. The common practice is to use regression models, as cross calibration formulas. However, such models do not attempt to discriminate between the clutter and the true functional relationship between the cross calibrated measurement methods. A new approach is proposed, based on minimizing the sum of squares of the differences between the absolute values of the Fast Fourier Transform (FFT) series, derived from the readings of the cross calibrated measurement methods. The line taken is illustrated by cross calibration examples of simulated linear and nonlinear measurement systems, with various levels of additive noise, wherein the new method is compared to the classical regression techniques. It is shown, that the new method can discover better the true functional relationship between two measurement systems, which is occluded by the noise.


Author(s):  
Joseph W. Palese ◽  
Sergio DiVentura ◽  
Ken Hill ◽  
Peter Maurice

Maintaining track geometry is key to the safe and efficient operations of a railroad. Failure to properly maintain geometry can lead to costly track structure failures or even more costly derailments. Currently, there exists a number of different methods for measuring track geometry and then if required, maintaining the track to return track geometry to specified levels of acceptance. Because of this need to have proper track geometry, tampers are one of the most common pieces of maintenance equipment in a railroad operation’s fleet. It is therefore paramount from both a cost and track time perspective to gain maximum efficiency from any one particular tamper. Track geometry is typically measured through a variety of contact and non-contact measurement systems which can mount on a variety of different platforms. With respect to a tamper, a push buggy projector system is typically used to measure track geometry, utilizing the tamper body as the basis for the reference system, Track geometry can be measured utilizing this technology during a prerecording run. Then, the software onboard the tamper analyzes the recorded data to determine the best fit and calculate throws that achieve a better track alignment, particularly in curves. During the tamping operation, the tamper buggy system and frame adjust the track. Due to its design, track geometry measurements can only be made at low speed (roughly 4mph) which can severely affect the efficiency of the tamper. To help decrease pre maintenance inspection times, an inertial based track geometry measurement system has been developed and integrated into the tamper’s operating software. This system can mount directly to the frame of a tamper and operate at hy-rail to very low speeds. Measurements made can be fed directly into the tamper control system to guide where and how track geometry adjustments need to be made. In addition, the capability to collect data during travel mode without the buggies extended allows for the collection of data at any time. Thus, data can be recorded when traveling back and forth to a stabling location, before and/or after grinding. This allows for synchronization of data at a later time to utilize for adjusting the track. Also, data can be collected post-work to allow for the comparison of pre and post geometry to allow for the determination of the effectiveness of a given tamping operation. Tampers equipped with this track geometry system facilitate the foundation for an enterprise solution. Data that is measured and collected can be sent to a cloud service, in real time that will provide exception reports, health status, and rail health trend analyses. Utilizing the available technology further optimizes response time in track maintenance. This paper will introduce this new method of mounting and completely integrating an inertial based track geometry system onto a tamper. In addition, studies will be presented which confirm the ability of this system to replicate the tamper’s projection based track geometry system. Finally, a comprehensive study on efficiency gains will be presented directly comparing a standard method of maintaining a segment via a tamper to this new method of using onboard inertial track geometry measurement.


2021 ◽  
Vol 2021 ◽  
pp. 1-13
Author(s):  
Lei Xu ◽  
Ning Zhang ◽  
Liqing Fang ◽  
Huadong Chen ◽  
Pengfei Lin ◽  
...  

The magnetic gradient full-tensor measurement system is diverse, and the magnetometer array structure is complex. Aimed at the problem, seven magnetic gradient full-tensor measurement system models are studied in detail. The full-tensor measurement theories of the tensor measurement arrays are analyzed. Under the same baseline distance, the magnetic dipole model is used to simulate the measurement system. Based on different measurement systems, the paper quantitatively compares and analyzes the error of the structure. A more optimized magnetic gradient full-tensor measurement system is suggested. The simulation results show that the measurement accuracy of the planar measurement system is slightly higher than that of the stereo measurement system. Among them, the cross-shaped and square measurement systems have relatively smaller structural errors and higher measurement accuracy.


Author(s):  
Loc Le Xuan ◽  
Bernard Fleury ◽  
Philippe Salamitou

2011 ◽  
Vol 101-102 ◽  
pp. 593-596
Author(s):  
Shao Feng Shen ◽  
Xian Cheng Wang ◽  
Jun Hua Chen

There is a problem with non-contact measurement and detection, which reduces its measurement accuracy. Methods developed for measuring and inspecting screw thread characteristic parameters usually using a camera, which is controlled to scan the projection of thread in the parallel optical field to obtain thread images. However, with the block of screw line on the projection of the real thread form, it is impossible to acquire the real thread form from images. The traditional way is adjusting the optical axis to a suitable angle with the thread axis to acquire the real thread form projection, which has some problems, such as time consuming, high skill of operator, high-precision equipment for adjustment, inaccuracy, and so on. Hence, a new method through digital image calibration is presented. The results of relevant simulation indicated the feasibility of this new method, which improves thread measurement and detection accuracy.


2011 ◽  
Vol 495 ◽  
pp. 53-57
Author(s):  
Marco Borotto ◽  
Enrico De Cais ◽  
Marco Belloli ◽  
Andrea Bernasconi ◽  
Stefano Manzoni

The fiber Bragg grating sensors (FBGs) have been recently introduced: they present a photorecord grating on the fiber itself, which allows the reflection of a certain wavelength of the input light spectrum. The applied strain is estimated relying on changes of the reflected wavelength. One of the possible applications that has prompted us to study this type of sensors is the possibility to create smart dynamometric structures based on carbon fiber by embedding FBGs. Many papers are available in literature about some applications with smart structures but there is not yet an appropriate metrological characterization about these FBG sensors, their strengths and weaknesses: for these reasons it was deemed useful making several tests on FBG sensors in terms of measurement accuracy, signal to noise ratio, ability to compensate for thermal effects and their behavior for dynamic applications. All these results have been compared to electrical strain gauge ones, which represent the actual reference strain measurement systems. The various solutions to compensate for thermal effects have offered several information for further analyses and the basis for a future use of these sensors for static or semi-static tests. Being fully aware of FBGs characteristics allows to draw down guidelines about their integration in composite materials for the most different applications, understanding in a better way the sensor response.


2019 ◽  
Vol 13 (1) ◽  
pp. 109-116 ◽  
Author(s):  
Yuki Fujihara ◽  
Shigeo Fukunishi ◽  
Tomokazu Fukui ◽  
Shoji Nishio ◽  
Yu Takeda ◽  
...  

Introduction: We have developed and utilized the Gravity-guide (G-guide) as a simple manual instrument for intraoperative assessment and adjustment of stem anteversion (AV). Since 2013, we simultaneously measured stem AV using the G-guide and image-free navigation during THA procedure. The purpose of this study was to compare the measurement accuracy of the G-guide and navigation system using the postoperative CT results as a reference. Methods: In total, 59 hips in 56 patients who underwent primary THA using both the G-guide and image-free navigation system were included in the study. All patients underwent postoperative CT examination, and the femoral stem AV was assessed using a 3D image analysis system (Zed hip, LEXI, Japan). The AV angle derived from the postoperative CT image analysis was used as the reference value to assess the accuracy of the two intraoperative measurement systems. Results: The discrepancy between the G-guide and the postoperative CT-measured values averaged 5.0° ± 3.9°, while the corresponding value for the navigation system was 5.2° ± 4.1°. Acceptable accuracy with a measurement error of less than 10° was achieved in 86% and 90% of the cases for the G-guide and navigation measurements respectively. Conclusion: Consequently, it was shown that both navigation and G-guide measurements can achieve comparative accuracy and are clinically useful.


Sign in / Sign up

Export Citation Format

Share Document