Tripping of F-type RCDs for High-Frequency Residual Currents

Author(s):  
Hanan Tariq ◽  
Stanislaw Czapp
2021 ◽  
Vol 19 ◽  
pp. 67-72
Author(s):  
T. M. H. Slangen ◽  
◽  
B. R. F. Lustenhouwer ◽  
V. Cuk ◽  
J. F. G. Cobben

This research investigates the effects of high frequency currents between 50 Hz and 150 kHz on the operation of Residual Current Devices (RCDs). Nowadays, the increasing amount of large power-electronic switching devices can be a source of both harmonics (<2 kHz) and supraharmonics (2-150 kHz) currents injected to the grid. This can have several effects and possibly lead to unwanted tripping of RCDs, due to high earth-currents that can be emitted by the devices. The question is if supraharmonics can also lead to misoperation or fail-to-operate conditions for the RCDs, potentially leading to serious safety risks. A set-up is developed to introduce both 50 Hz and highfrequency leakage currents. First, the 50 Hz tripping-current of the RCDs is tested under nominal conditions. Secondly, the tripping current for non-nominal frequencies (between 50 Hz and 150 kHz) is determined to verify the possibility for false tripping. Lastly, the 50 Hz tripping current for the RCD is tested in the presence of a high-frequency current. The most important conclusion is that RCDs of type A and AC have an increased fundamental (50 Hz) tripping current when there are HFcomponents present. This potentially results in a safety risk.


2014 ◽  
Vol 31 (4) ◽  
pp. 945-966 ◽  
Author(s):  
I. I. Rypina ◽  
A. R. Kirincich ◽  
R. Limeburner ◽  
I. A. Udovydchenkov

Abstract This study investigated the correspondence between the near-surface drifters from a mass drifter deployment near Martha’s Vineyard, Massachusetts, and the surface current observations from a network of three high-resolution, high-frequency radars to understand the effects of the radar temporal and spatial resolution on the resulting Eulerian current velocities and Lagrangian trajectories and their predictability. The radar-based surface currents were found to be unbiased in direction but biased in magnitude with respect to drifter velocities. The radar systematically underestimated velocities by approximately 2 cm s−1 due to the smoothing effects of spatial and temporal averaging. The radar accuracy, quantified by the domain-averaged rms difference between instantaneous radar and drifter velocities, was found to be about 3.8 cm s−1. A Lagrangian comparison between the real and simulated drifters resulted in the separation distances of roughly 1 km over the course of 10 h, or an equivalent separation speed of approximately 2.8 cm s−1. The effects of the temporal and spatial radar resolution were examined by degrading the radar fields to coarser resolutions, revealing the existence of critical scales (1.5–2 km and 3 h) beyond which the ability of the radar to reproduce drifter trajectories decreased more rapidly. Finally, the importance of the different flow components present during the experiment—mean, tidal, locally wind-driven currents, and the residual velocities—was analyzed, finding that, during the study period, a combination of tidal, locally wind-driven, and mean currents were insufficient to reliably reproduce, with minimal degradation, the trajectories of real drifters. Instead, a minimum combination of the tidal and residual currents was required.


2021 ◽  
Vol 893 (1) ◽  
pp. 012053
Author(s):  
R Firdaus ◽  
E L Siadari ◽  
F Alfahmi

Abstract High-Frequency (HF) Radar is an instrument using radio waves to measure ocean currents and waves remotely. This technology has many advantages, including has unprecedented spatial and temporal resolution, can operate in any weather condition, and is not dangerous for the environment. However, HF Radar's research is still limited in Indonesia. This research aimed to analyze the tidal and residual current in the Bali Strait in July 2020. Radial velocity from two HF Radar sites is combined to obtain the total currents. Current data from HF Radar were compared with Acoustic Doppler Current Profiler (ADCP) data to investigate its accuracy. Surface current data were analyzed using harmonic analysis to separate tidal and residual currents. Comparison between HF Radar and ADCP data are in good agreement for meridional current with a very high correlation of 0.813 and a small RMSE value of 0.22 m/s. Harmonic analysis shows that the dominant currents are tidal currents. The current direction was northward (southward) at flood (ebb), with maximum northward (southward) velocities are 2.17 m/s (2.97 m/s), respectively. The residual current has a random pattern, slightly faster northward than southward, and has similar spectral with the wind.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

2020 ◽  
Vol 29 (3) ◽  
pp. 429-435
Author(s):  
Patricia C. Mancini ◽  
Richard S. Tyler ◽  
Hyung Jin Jun ◽  
Tang-Chuan Wang ◽  
Helena Ji ◽  
...  

Purpose The minimum masking level (MML) is the minimum intensity of a stimulus required to just totally mask the tinnitus. Treatments aimed at reducing the tinnitus itself should attempt to measure the magnitude of the tinnitus. The objective of this study was to evaluate the reliability of the MML. Method Sample consisted of 59 tinnitus patients who reported stable tinnitus. We obtained MML measures on two visits, separated by about 2–3 weeks. We used two noise types: speech-shaped noise and high-frequency emphasis noise. We also investigated the relationship between the MML and tinnitus loudness estimates and the Tinnitus Handicap Questionnaire (THQ). Results There were differences across the different noise types. The within-session standard deviation averaged across subjects varied between 1.3 and 1.8 dB. Across the two sessions, the Pearson correlation coefficients, range was r = .84. There was a weak relationship between the dB SL MML and loudness, and between the MML and the THQ. A moderate correlation ( r = .44) was found between the THQ and loudness estimates. Conclusions We conclude that the dB SL MML can be a reliable estimate of tinnitus magnitude, with expected standard deviations in trained subjects of about 1.5 dB. It appears that the dB SL MML and loudness estimates are not closely related.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


Sign in / Sign up

Export Citation Format

Share Document