The Effects of Verbal Cueing for High Intended Movement Velocity on Power, Neuromuscular Activation and Performance.

Author(s):  
Michael Rheese ◽  
Eric J. Drinkwater ◽  
Hans Leung ◽  
Justin W. Andrushko ◽  
Jacob Tober ◽  
...  
2009 ◽  
Vol 23 (6) ◽  
pp. 1773-1779 ◽  
Author(s):  
Thomas A Kyriazis ◽  
Gerasimos Terzis ◽  
Konstantinos Boudolos ◽  
Georgios Georgiadis

2021 ◽  
Vol 6 (4) ◽  
pp. 96
Author(s):  
Michael O. Harris-Love ◽  
Jared M. Gollie ◽  
Justin W. L. Keogh

The goals of this narrative review are to provide a brief overview of the muscle and tendon adaptations to eccentric resistance exercise and address the applications of this form of training to aid rehabilitative interventions and enhance sports performance. This work is centered on the author contributions to the Special Issue entitled “Eccentric Exercise: Adaptations and Applications for Health and Performance”. The major themes from the contributing authors include the need to place greater attention on eccentric exercise mode selection based on training goals and individual fitness level, optimal approaches to implementing eccentric resistance exercise for therapeutic purposes, factors that affect the use of eccentric exercise across the lifespan, and general recommendations to integrate eccentric exercise in athletic training regimens. The authors propose that movement velocity and the absorption or recovery of kinetic energy are critical components of eccentric exercise programming. Regarding the therapeutic use of eccentric resistance training, patient-level factors regarding condition severity, fitness level, and stage of rehabilitation should govern the plan of care. In athletic populations, use of eccentric exercise may improve movement competency and promote improved safety and performance of sport-specific tasks. Eccentric resistance training is a viable option for youth, young adults, and older adults when the exercise prescription appropriately addresses program goals, exercise tolerability, and compliance. Despite the benefits of eccentric exercise, several key questions remain unanswered regarding its application underscoring the need for further investigation.


Motricidade ◽  
2017 ◽  
Vol 13 (1) ◽  
pp. 1 ◽  
Author(s):  
Mário C. Marques

Intensity during strength training has been commonly identified with relative load (percentage of one-repetition maximum, 1RM) or with performing a given maximal number of repetitions in each set (XRM: 5RM, 10RM, 15 RM, etc.). Yet, none of these methods can be appropriate for precisely monitoring the real training effort in each training session.The first approach requires coaches to individually assess the 1RM value for each athlete. We may agree that expressing intensity as a percentage of the maximum repetition has the advantage that it can be used to program strength training for multiple athletes simultaneously, the loads being later transformed in absolute values (kg) for each individual. Further, another advantage is that this expression of the intensity can clearly reflect the dynamics of the evolution of the training load if we understand the percentage of 1RM as an effort, and not as a simple arithmetic calculus. Nevertheless, direct assessment of 1RM has some possible disadvantages worth noting. It may be associated with risk of injury when performed incorrectly or by novice athlete’s and it is time-consuming and impractical for large groups. Moreover, the actual RM can change quite rapidly after only a few training sessions and often the obtained value is not the subject’s true maximum.The classic way to prescribe loading intensity is to determine, through trial and error, the maximum number of repetitions that one can be performed with a given submaximal weight. For example, 5RM refers to a weight that can only be lifted five times. Some studies identified the relationship between selected percentages of 1RM and the number of repetitions to failure, establishing a repetition maximum continuum. It is believed that certain performance characteristics are best trained using specific RM load ranges. This method eliminates the need for a direct 1RM test, but it is not without drawbacks either. Using exhaustive efforts is common practice in strength training, but increasing evidence (Sanborn et al., 2000; Folland et al., 2002; Izquierdo et al., 2006; Drinkwater et al., 2007) shows that training to repetition failure does not necessarily produce better strength gains and that may even be counterproductive by inducing excessive fatigue, mechanical and metabolic strain (Fry, 2004). In fact, fatigue associated with training to failure not only significantly reduces the force that a muscle can generate, but also the nervous system’s ability to voluntarily activate the muscles (Häkkinen, 1993). Consequently, this approach, besides being very tiring and having shown no advantage over other lower effort types of training, it is unrealistic because it is practically impossible to know exactly how many repetitions can be done with a given absolute load without any initial reference. In addition, if in the first set the subject has completed the maximum number of repetitions, it will be very difficult or even impossible to perform properly the same number of reps in the following sets.Movement velocity is another variable which could be of great interest for monitoring exercise intensity, but surprisingly it has been vaguely mentioned in most studies to date. The importance that monitoring movement velocity for strength training programming have already been noticed in 1991 (González-Badillo, 1991). More recently, González-Badillo and Sánchez-Medina (2010, 2011) studied this hypothesis and confirmed that movement velocity provides as a determinant of the level of effort during resistance training as well as an indicator of the degree of fatigue. Unfortunately, the lack of use of this variable is likely because until recently it was not possible to accurately measure velocity in isoinertial strength training exercises/movements.  Indeed, most research that has addressed movement velocity in strength training was basically conducted using isokinetic apparatus which, unfortunately, is not an ideal or common training practice. The actual velocity performed in each repetition could be the best reference to determine accurately the real metabolic effort for each athlete. The higher the velocity achieved against a given (absolute) load, the greater the intensity with positive consequences for training effect (González Badillo and Ribas, 2002). Therefore, movement velocity should be the main “ingredient” of training intensity. With this approach, instead of a certain amount of weight to be lifted, coaches must be encouraging to prescribe strength training according to two important variables: 1) first repetition’s mean velocity, which is intrinsically related to loading intensity; and 2) a maximum percent velocity loss to be allowed in each set. When this percent loss limit is exceeding the set must be terminated. The limit of repetition velocity loss should be set beforehand depending on the primary training goal being pursued, the particular exercise to be performed as well as the training experience and performance level of each athlete.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


1986 ◽  
Vol 50 (5) ◽  
pp. 264-267 ◽  
Author(s):  
GH Westerman ◽  
TG Grandy ◽  
JV Lupo ◽  
RE Mitchell

2008 ◽  
Vol 17 (3) ◽  
pp. 87-92
Author(s):  
Leonard L. LaPointe

Abstract Loss of implicit linguistic competence assumes a loss of linguistic rules, necessary linguistic computations, or representations. In aphasia, the inherent neurological damage is frequently assumed by some to be a loss of implicit linguistic competence that has damaged or wiped out neural centers or pathways that are necessary for maintenance of the language rules and representations needed to communicate. Not everyone agrees with this view of language use in aphasia. The measurement of implicit language competence, although apparently necessary and satisfying for theoretic linguistics, is complexly interwoven with performance factors. Transience, stimulability, and variability in aphasia language use provide evidence for an access deficit model that supports performance loss. Advances in understanding linguistic competence and performance may be informed by careful study of bilingual language acquisition and loss, the language of savants, the language of feral children, and advances in neuroimaging. Social models of aphasia treatment, coupled with an access deficit view of aphasia, can salve our restless minds and allow pursuit of maximum interactive communication goals even without a comfortable explanation of implicit linguistic competence in aphasia.


Sign in / Sign up

Export Citation Format

Share Document