scholarly journals Investigations on Crystallization Processes of Three Oxidic Gasifier Slag Systems

2020 ◽  
Vol 142 (7) ◽  
Author(s):  
Jan Peter Schupsky ◽  
Muxing Guo ◽  
Bart Blanpain ◽  
Michael Müller

Abstract In entrained flow gasifiers, the production of oxidic slag accompanies the gasification process. This slag forms a layer on the refractory walls, flows downwards gravitationally, and is collected in a water quench. Hence, the slag flow must be constant, since a slag blockage represents a worst-case-scenario. Crystallization of the slag increases slag viscosity, subsequently leading to a possible slag blockage. Therefore, crystallization processes in oxidic slags need to be understood and hence investigated. In this study, three artificial, coal ash related oxidic slag systems were analyzed on their crystallization behavior. Therefore, their melt behavior was investigated via hot-stage microscopy and differential thermal analysis (DTA). Additional thermochemical calculations were performed to predict crystallized phases. Subsequently, quenching experiments were conducted to generate supercooled crystallization in the slag samples. These samples were analyzed afterward via X-ray diffraction (XRD) and scanning electron microscopy (SEM), and the morphologies of crystals were characterized/described. In-situ observations on crystallization growth were performed by using a confocal laser scanning microscope (CLSM). Finally, crystallized phases were compared with results obtained from thermochemical calculations, and the impact of kinetics on the distributed phases was discussed. The knowledge on the crystallization behavior of various phases can be transferred to other slag systems and can improve general crystallization predictions made by thermochemical calculations.

2019 ◽  
Vol 809 ◽  
pp. 439-444 ◽  
Author(s):  
Henning Hasselbruch ◽  
Y. Lu ◽  
H. Messaoudi ◽  
Andreas Mehner ◽  
Frank Vollertsen

An increase of the service life of tribological systems subjected to dynamic-mechanical loads is important for numerous mechanical applications. The present study deals with the impact of several micro-structured surface topographies of graded Cr/CrNx/(Cr,W)Cy/a-C:H:W/a-C:H PVD hard coatings on their friction and wear behavior. The coatings were applied by reactive magnetron sputtering on a hardened 1.2379 steel substrates and subsequently micro-structured by laser ablation using a picosecond laser. Pin-on-disc tests were carried out against aluminum under both oil lubrication and dry conditions. The diameters of the micro-dimples were varied between 50 μm, 100 μm and 150 μm at a constant degree of coating coverage of about 60 %. The coefficients of friction and wear were determined after 20,000 cycles by confocal laser-scanning microscope (CLSM), scanning electron microscopy (SEM) and by energy-dispersive X-ray spectroscopy (EDX) to analyze possible transfer layer formations.


Author(s):  
Thomas M. Jovin ◽  
Michel Robert-Nicoud ◽  
Donna J. Arndt-Jovin ◽  
Thorsten Schormann

Light microscopic techniques for visualizing biomolecules and biochemical processes in situ have become indispensable in studies concerning the structural organization of supramolecular assemblies in cells and of processes during the cell cycle, transformation, differentiation, and development. Confocal laser scanning microscopy offers a number of advantages for the in situ localization and quantitation of fluorescence labeled targets and probes: (i) rejection of interfering signals emanating from out-of-focus and adjacent structures, allowing the “optical sectioning” of the specimen and 3-D reconstruction without time consuming deconvolution; (ii) increased spatial resolution; (iii) electronic control of contrast and magnification; (iv) simultanous imaging of the specimen by optical phenomena based on incident, scattered, emitted, and transmitted light; and (v) simultanous use of different fluorescent probes and types of detectors.We currently use a confocal laser scanning microscope CLSM (Zeiss, Oberkochen) equipped with 3-laser excitation (u.v - visible) and confocal optics in the fluorescence mode, as well as a computer-controlled X-Y-Z scanning stage with 0.1 μ resolution.


Author(s):  
Thomas J. Deerinck ◽  
Maryann E. Martone ◽  
Varda Lev-Ram ◽  
David P. L. Green ◽  
Roger Y. Tsien ◽  
...  

The confocal laser scanning microscope has become a powerful tool in the study of the 3-dimensional distribution of proteins and specific nucleic acid sequences in cells and tissues. This is also proving to be true for a new generation of high contrast intermediate voltage electron microscopes (IVEM). Until recently, the number of labeling techniques that could be employed to allow examination of the same sample with both confocal and IVEM was rather limited. One method that can be used to take full advantage of these two technologies is fluorescence photooxidation. Specimens are labeled by a fluorescent dye and viewed with confocal microscopy followed by fluorescence photooxidation of diaminobenzidine (DAB). In this technique, a fluorescent dye is used to photooxidize DAB into an osmiophilic reaction product that can be subsequently visualized with the electron microscope. The precise reaction mechanism by which the photooxidation occurs is not known but evidence suggests that the radiationless transfer of energy from the excited-state dye molecule undergoing the phenomenon of intersystem crossing leads to the formation of reactive oxygen species such as singlet oxygen. It is this reactive oxygen that is likely crucial in the photooxidation of DAB.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


TAPPI Journal ◽  
2010 ◽  
Vol 9 (10) ◽  
pp. 7-15
Author(s):  
HANNA KOIVULA ◽  
DOUGLAS BOUSFIELD ◽  
MARTTI TOIVAKKA

In the offset printing process, ink film splitting has an important impact on formation of ink filaments. The filament size and its distribution influence the leveling of ink and hence affect ink setting and the print quality. However, ink filaments are difficult to image due to their short lifetime and fine length scale. Due to this difficulty, limited work has been reported on the parameters that influence filament size and methods to characterize it. We imaged ink filament remains and quantified some of their characteristics by changing printing speed, ink amount, and fountain solution type. Printed samples were prepared using a laboratory printability tester with varying ink levels and operating settings. Rhodamine B dye was incorporated into fountain solutions to aid in the detection of the filaments. The prints were then imaged with a confocal laser scanning microscope (CLSM) and images were further analyzed for their surface topography. Modeling of the pressure pulses in the printing nip was included to better understand the mechanism of filament formation and the origin of filament length scale. Printing speed and ink amount changed the size distribution of the observed filament remains. There was no significant difference between fountain solutions with or without isopropyl alcohol on the observed patterns of the filament remains.


2016 ◽  
Vol 6 (01) ◽  
pp. 5218
Author(s):  
Laxmi Mohandas ◽  
Anju T. R. ◽  
Sarita G. Bhat*

An assortment of redox-active phenazine compounds like pyocyanin with their characteristic blue-green colour are synthesized by Pseudomonas aeruginosa, Gram-negative opportunistic pathogens, which are also considered one of the most commercially valuable microorganisms. In this study, pyocyanin from Pseudomonas aeruginosa BTRY1 from food sample was assessed for its antibiofilm activity by micro titer plate assay against strong biofilm producers belonging to the genera Bacillus, Staphylococcus, Brevibacterium and Micrococcus. Pyocyanin inhibited biofilm activity in very minute concentrations. This was also confirmed by Scanning Electron Microscopy (SEM) and Confocal Laser Scanning Microscopy (CLSM). Both SEM and CLSM helped to visualize the biocontrol of biofilm formation by eight pathogens. The imaging and quantification by CLSM also established the impact of pyocyanin on biofilm-biocontrol mainly in the food industry.


2019 ◽  
Vol 10 ◽  
pp. 2182-2191 ◽  
Author(s):  
Tushar C Jagadale ◽  
Dhanya S Murali ◽  
Shi-Wei Chu

Nonlinear nanoplasmonics is a largely unexplored research area that paves the way for many exciting applications, such as nanolasers, nanoantennas, and nanomodulators. In the field of nonlinear nanoplasmonics, it is highly desirable to characterize the nonlinearity of the optical absorption and scattering of single nanostructures. Currently, the common method to quantify optical nonlinearity is the z-scan technique, which yields real and imaginary parts of the permittivity by moving a thin sample with a laser beam. However, z-scan typically works with thin films, and thus acquires nonlinear responses from ensembles of nanostructures, not from single ones. In this work, we present an x-scan technique that is based on a confocal laser scanning microscope equipped with forward and backward detectors. The two-channel detection offers the simultaneous quantification for the nonlinear behavior of scattering, absorption and total attenuation by a single nanostructure. At low excitation intensities, both scattering and absorption responses are linear, thus confirming the linearity of the detection system. At high excitation intensities, we found that the nonlinear response can be derived directly from the point spread function of the x-scan images. Exceptionally large nonlinearities of both scattering and absorption are unraveled simultaneously for the first time. The present study not only provides a novel method for characterizing nonlinearity of a single nanostructure, but also reports surprisingly large plasmonic nonlinearities.


Sign in / Sign up

Export Citation Format

Share Document