In-Hole Characteristic Interface and Film Cooling Interface Model

2021 ◽  
pp. 1-43
Author(s):  
Zhen Zhang ◽  
Hui Li ◽  
Xinrong Su ◽  
Xin Yuan

Abstract The performance of film cooling is influenced by many parameters, and the non-uniform flow caused by the internal cooling system is found to largely affect the film cooling, which further complicates the in-hole flow and draws new difficulties in predicting the cooling performance. In this work, we find a very interesting phenomenon that there always exists an in-hole interface, on which distributions of many parameters, including the velocity and kinetic energy, are seldom affected by the mainstream. The existence of this specific interface can be observed for both cylindrical and shaped film holes under most operating conditions. Theoretical analysis of this interface is conducted in this work based on the characteristic decomposition of Navier-Stokes equations and this interface is named as the characteristic interface. Theoretical analysis and numerical observations suggest the film cooling system can be simplified to two weakly coupled regions separated by this interface. It also explains why existing source-term models for film cooling may fail. Based on these findings, a new prediction model is developed, which uses the Convolutional Neural Networks (CNN) to predict boundary conditions on the characteristic interface. The new model outperforms existing source-term models and yields similar accuracy as full-mesh CFD, while reducing computational cost by one order of magnitude. This model is further evaluated in LES, showing moderate success. To sum up, current work reports the characteristic interface phenomenon in film cooling holes, based on which a new and efficient prediction model is developed and verified.

2021 ◽  
pp. 1-21
Author(s):  
Z. Hao ◽  
X. Yang ◽  
Z. Feng

Abstract Particulate deposits in aero-engine turbines change the profile of blades, increase the blade surface roughness and block internal cooling channels and film cooling holes, which generally leads to the degradation of aerodynamic and cooling performance. To reveal particle deposition effects in the turbine, unsteady simulations were performed by investigating the migration patterns and deposition characteristics of the particle contaminant in a one-stage, high-pressure turbine of an aero-engine. Two typical operating conditions of the aero-engine, i.e. high-temperature take-off and economic cruise, were discussed, and the effects of particle size on the migration and deposition of fly-ash particles were demonstrated. A critical velocity model was applied to predict particle deposition. Comparisons between the stator and rotor were made by presenting the concentration and trajectory of the particles and the resulting deposition patterns on the aerofoil surfaces. Results show that the migration and deposition of the particles in the stator passage is dominated by the flow characteristics of fluid and the property of particles. In the subsequential rotor passage, in addition to these factors, particles are also affected by the stator–rotor interaction and the interference between rotors. With higher inlet temperature and larger diameter of the particle, the quantity of deposits increases and the deposition is distributed mainly on the Pressure Side (PS) and the Leading Edge (LE) of the aerofoil.


Author(s):  
Grzegorz Nowak

This paper discusses the problem of cooling system optimization within a gas turbine airfoil regarding to thermo-mechanical behavior of the component, as well as some economical aspects of turbine operation. The main goal of this paper is to show the possibilities of evolutionary approach application to the cooling system optimization. This method, despite its relatively high computational cost, seems to be a valuable tool to such technical problems. The analysis involves the optimization of location and size of internal cooling passages within an airfoil. Initially cooling is provided with circular passages and heat is transported by convection. During the optimization the number of channels can vary. The task is approached in 3D configuration. Each passage is fed with cooling air of constant parameters at the inlet. Also a constant pressure drop is assumed along the passage length. The thermal boundary conditions in passages vary with diameter and local vane temperature (passage wall temperature). The analysis is performed by means of the genetic algorithm for the optimization task and FEM for the heat transfer predictions within the component. In the present study the airfoil profile is taken as aerodynamically optimal and the objective of the search procedure is to find cooling structure variant that at given external conditions provides lower stresses, material temperature and indirectly coolant usage.


Author(s):  
D. Jackson ◽  
P. Ireland ◽  
B. Cheong

Progress in the computing power available for CFD predictions now means that full geometry, 3 dimensional predictions are now routinely used in internal cooling system design. This paper reports recent work at Rolls-Royce which has compared the flow and htc predictions in a modern HP turbine cooling system to experiments. The triple pass cooling system includes film cooling vents and inclined ribs. The high resolution heat transfer experiments show that different cooling performance features are predicted with different levels of fidelity by the CFD. The research also revealed the sensitivity of the prediction to accurate modelling of the film cooling hole discharge coefficients and a detailed comparison of the authors’ computer predictions to data available in the literature is reported. Mixed bulk temperature is frequently used in the determination of heat transfer coefficient from experimental data. The current CFD data is used to compare the mixed bulk temperature to the duct centreline temperature. The latter is measured experimentally and the effect of the difference between mixed bulk and centreline temperature is considered in detail.


Author(s):  
Felipe A. C. Viana ◽  
Jack Madelone ◽  
Niranjan Pai ◽  
Genghis Khan ◽  
Sanghum Baik

To achieve high efficiency, modern gas turbines operate at temperatures that exceed melting points of metal alloys used in turbine hot gas path parts. Parts exposed to hot gas are actively cooled with a portion of the compressor discharge air (e.g., through film cooling) to keep the metal temperature at levels needed to meet durability requirements. However, to preserve efficiency, it is important to optimize the cooling system to use the least amount of cooling flow. In this study, film cooling optimization is achieved by varying cooling hole diameters, hole to hole spacing, and film row placements so that the specified targets for maximum metal temperature are met while preserving (or saving) cooling flow. The computational cost of the high-fidelity physics models, the large number of design variables, the large number and nonlinearity of responses impose severe challenges to numerical optimization. Design of experiments and cheap-to-evaluate approximations (radial basis functions) are used to alleviate the computational burden. Then, the goal attainment method is used for optimizing of film cooling configuration. The results for a turbine blade design show significant improvements in temperature distribution while maintaining/reducing the amount of used cooling flow.


2016 ◽  
Vol 139 (3) ◽  
Author(s):  
Sebastien Wylie ◽  
Alexander Bucknell ◽  
Peter Forsyth ◽  
Matthew McGilvray ◽  
David R. H. Gillespie

Internal cooling passages of turbine blades have long been at risk to blockage through the deposition of sand and dust during fleet service life. The ingestion of high volumes of volcanic ash (VA) therefore poses a real risk to engine operability. An additional difficulty is that the cooling system is frequently impossible to inspect in order to assess the level of deposition. This paper reports results from experiments carried out at typical high pressure (HP) turbine blade metal temperatures (1163 K to 1293 K) and coolant inlet temperatures (800 K to 900 K) in engine scale models of a turbine cooling passage with film-cooling offtakes. Volcanic ash samples from the 2010 Eyjafjallajökull eruption were used for the majority of the experiments conducted. A further ash sample from the Chaiten eruption allowed the effect of changing ash chemical composition to be investigated. The experimental rig allows the metered delivery of volcanic ash through the coolant system at the start of a test. The key metric indicating blockage is the flow parameter (FP), which can be determined over a range of pressure ratios (1.01–1.06) before and after each experiment, with visual inspection used to determine the deposition location. Results from the experiments have determined the threshold metal temperature at which blockage occurs for the ash samples available, and characterize the reduction of flow parameter with changing particle size distribution, blade metal temperature, ash sample composition, film-cooling hole configuration and pressure ratio across the holes. There is qualitative evidence that hole geometry can be manipulated to decrease the likelihood of blockage. A discrete phase computational fluid dynamics (CFD) model implemented in Fluent has allowed the trajectory of the ash particles within the coolant passages to be modeled, and these results are used to help explain the behavior observed.


Author(s):  
Miki Koyama ◽  
Toshio Mimaki

This aims to put the fruits of the R&D; “The Hydrogen Combustion Turbine” in WE-NET Phase I Program(1993-1998) to practical use at an early stage. The topping regenerating cycle was selected as the optimum cycle, with energy efficiency expected to be more than 60%(HHV) under the conditions of the turbine inlet temperature of 1973K(1700°C) and the pressure of 4.8MPa,in it. • As the turbine inlet temperature and pressure increase, issues to be resolved include the amount of NOx emissions and the durability of super alloys for turbine blades under such thermal conditions. In this respect, the development of the highly efficient methane-oxygen combustion technology, the turbine blade cooling technology, and the ultrahigh-temperature materials including thermal barrier coatings is being carried out. • In 1999, the results made it clear that there are little error among the three analytic programs used to verify the system efficiency, it was verified that the burning rate was going to arrive at over 98% from the methane-oxygen combustion test (under the atmospheric pressure). And the type of vane “Film cooling plus recycle type with internal cooling system” was selected as the most suitable vane.


Author(s):  
Rémy Fransen ◽  
Nicolas Gourdain ◽  
Laurent Y. M. Gicquel

This work focuses on numerical simulations of flows in blade internal cooling system. Large Eddy Simulation (LES) and Reynolds-Averaged Navier Stokes (RANS) approaches are compared in a typical blade cooling related problem. The case is a straight rib-roughened channel with high blockage ratio, computed and compared for both a periodic and full spatial domains. The configuration was measured at the Von Karman Institute (VKI) using Particle Image Velocimetry (PIV) in near gas turbine operating conditions. Results show that RANS models used fail to predict the full evolution of the flow within the channels where massive separation and large scale unsteady features are evidenced. In contrast LES succeeds in reproducing these complex flow motions and both mean and fluctuating components are clearly improved in the channels and in the near wall region. Periodic computations are gauged against the spatial computational domain and results on the heat transfer problem are addressed.


2020 ◽  
pp. 52-58
Author(s):  
Юрий Петрович Кухтин ◽  
Руслан Юрьевич Шакало

To reduce the vibration stresses arising in the working blades of turbines during resonant excitations caused by the frequency of passage of the blades of the nozzle apparatus, it is necessary to control the level of aerodynamic exciting forces. One of the ways to reduce dynamic stresses in rotor blades under operating conditions close to resonant, in addition to structural damping, maybe to reduce external exciting forces. To weaken the intensity of the exciting forces, it is possible to use a nozzle apparatus with multi-step gratings, as well as with non-radially mounted blades of the nozzle apparatus.This article presents the results of numerical calculations of exciting aerodynamic forces, as well as the results of experimental measurements of stresses arising in pairwise bandaged working blades with a frequency zCA ⋅ fn, where fn – is the rotor speed, zCA – is the number of nozzle blades. The object of research was the high-pressure turbine stage of a gas turbine engine. Two variants of a turbine stage were investigated: with the initial geometry of the nozzle apparatus having the same geometric neck area in each interscapular channel and with the geometry of the nozzle apparatus obtained by alternating two types of sectors with a reduced and initial throat area.The presented results are obtained on the basis of numerical simulation of a viscous unsteady gas flow in a transonic turbine stage using the SUnFlow home code, which implements a numerical solution of the Reynolds-averaged Navier-Stokes equations. Discontinuity of a torrent running on rotor blades is aggravated with heat drops between an ardent flow core and cold jets from film cooling of a blade and escapes on clock surfaces. Therefore, at simulation have been allowed all blowngs cooling air and drain on junctions of shelves the impeller.As a result of the replacement of the nozzle apparatus with a constant passage area by a nozzle apparatus with a variable area, a decrease in aerodynamic driving force by 12.5 % was obtained. The experimentally measured stresses arising in a pairwise bandaged blade under the action of this force decreased on average by 26 %.


Author(s):  
Sebastien Wylie ◽  
Alexander Bucknell ◽  
Peter Forsyth ◽  
Matthew McGilvray ◽  
David R. H. Gillespie

Internal cooling passages of turbine blades have long been at risk to blockage through the deposition of sand and dust during fleet service life. The ingestion of high volumes of volcanic ash therefore poses a real risk to engine operability. An additional difficulty is that the cooling system is frequently impossible to inspect in order to assess the level of deposition. This paper reports results from experiments carried out at typical HP turbine blade metal temperatures (1163K to 1293K) and coolant inlet temperatures (800K to 900K) in engine scale models of a turbine cooling passage with film-cooling offtakes. Volcanic ash samples from the 2010 Eyjafjallajökull eruption were used for the majority of the experiments conducted. A further ash sample from the Chaiten eruption allowed the effect of changing ash chemical composition to be investigated. The experimental rig allows the metered delivery of volcanic ash through the coolant system at the start of a test. The key metric indicating blockage is the flow parameter which can be determined over a range of pressure ratios (1.01–1.06) before and after each experiment, with visual inspection used to determine the deposition location. Results from the experiments have determined the threshold metal temperature at which blockage occurs for the ash samples available, and characterise the reduction of flow parameter with changing particle size distribution, blade metal temperature, ash sample composition, film-cooling hole configuration and pressure ratio across the holes. There is qualitative evidence that hole geometry can be manipulated to decrease the likelihood of blockage. A discrete phase CFD model implemented in Fluent has allowed the trajectory of the ash particles within the coolant passages to be modelled, and these results are used to help explain the behaviour observed.


Sign in / Sign up

Export Citation Format

Share Document