scholarly journals High-Temperature Turbine Technology Readiness

Author(s):  
M. W. Horner ◽  
A. Caruvana

Final component and technology verification tests have been completed for application to a 2600°F rotor inlet temperature gas turbine. These tests have proven the capability of combustor, turbine hot section, and IGCC fuel systems and controls to operate in a combined cycle plant burning a coal-derived gas fuel at elevated gas turbine inlet temperatures (2600–3000°F). This paper presents recent test results and summarizes the overall progress made during the DOE-HTTT Phase II program.

Author(s):  
Eric Chia ◽  
Bruce S. Kang ◽  
Min Zheng ◽  
Yang Li ◽  
Minking Chyu

Current and future designs for advanced turbine systems, such as Integrated Gasification Combined Cycle (IGCC), advanced Natural Gas Combined Cycle (NGCC), and the emerging supercritical CO2 (SCO2) systems require increasing turbine inlet temperature (TIT), which is well beyond the substrate melting temperature. The well-known approach is coating the turbine blade with thermal barrier coatings (TBC) combined with internal cooling channel in the substrate. However, due to thermally grown oxide (TGO) and thermal expansion mismatch stresses, TBC spallation failure is a major concern. Furthermore, neither the ceramic coating layer nor the metallic bond coat in current TBC system can provide structural support to house the internal cooling channels. In this research, a method to fabricate high temperature protective structural coating on top of critical gas turbine components by additive manufacturing (AM) technique using oxide dispersion strengthening (ODS) metal powder is presented. A novel combined mechanochemical bonding (MCB) plus ball milling process is utilized to produce near spherical and uniformly alloyed ODS powders. AM-processed ODS coating by direct energy deposition (DED) method on MAR-247 substrate, with laser powers from 100W to 200W were carried out. The ODS coated samples were then subjected to thermal cyclic loadings for over 2200 cycles. For comparison, in our earlier studies, under the same cyclic testing condition, typical tested TBC coupons showed spallation failure after ∼400 cycles. Correlation of the measured ODS coating Young’s modulus using a unique non-destructive micro-indentation testing method with evolution of the ODS microstructures are studied to identify optimum AM processing parameters for best performance of the ODS samples. In particular, stability of secondary γ′ phase in the ODS coating after thermal cycles is analyzed. Test results revealed a thin steady durable alpha alumina oxide layer on the best performance ODS samples. After 2,200 thermal cycles, strong bonding at ODS/substrate interface is also maintained for most of the ODS coated samples. Test results also showed stable substrate microstructure due to the protective ODS coating even after 2,200 thermal cycles. These preliminary test results showed strong potential for applications of AM-assisted ODS coating on advanced gas turbine components.


Author(s):  
Feliciano Pava´n ◽  
Marco Romo ◽  
Juan Prince

The present paper is a thermodynamics analysis, i.e. both energy and exergy analyses for a natural gas based combined cycle power plant. The analysis was performed for an existing 240 MW plant, where the steam cycle reduces the irreversibilities during heat transfer from gas to water/steam. The effect of operating variables such as pressure ratio, gas turbine inlet temperature on the performance of combined cycle power plant has been investigated. The pressure ratio and maximum temperature (gas turbine inlet temperature) are identified as the dominant parameters having impact on the combined cycle plant performance. The work output of the topping cycle is found to increase with pressure ratio, while for the bottoming cycle it decreases. However, for the same gas turbine inlet temperature the overall work output of the combined cycle plant increases up to a certain pressure ratio, and thereafter not much increase is observed. The exergy losses of the individual components in the plant are evaluated based on second law of thermodynamics. The present results form a basis on which further work can be conducted to improve the performance of these units.


1980 ◽  
Author(s):  
R. L. Graves

The difficulties encountered in past and present efforts to operate direct coal-fired gas turbines are substantial. Hence the development effort required to assure a reliable, high-temperature pressurized fluidized bed (PFBC) combined cycle may be very expensive and time consuming. It is, therefore, important that the benefit of achieving high-temperature operation, which is primarily increased efficiency, be clearly understood at the outset of such a development program. This study characterizes the effects of PFBC temperature and pressure on plant efficiency over a wide range of values. There is an approximate three percentage point advantage by operating at a gas turbine inlet temperature of 870 C (1600 F) instead of 538 C (1000 F). Optimum pressure varies with the gas turbine inlet temperature, but ranges from 0.4–1.0 MPa (4–10 atm). An alternate PFBC cycle offering high efficiency at a peak temperature of about 650 C (1200 F) is also discussed.


Author(s):  
Daniel E. Caguiat

The Naval Surface Warfare Center, Carderock Division (NSWCCD) Gas Turbine Emerging Technologies Code 9334 was tasked by NSWCCD Shipboard Energy Office Code 859 to research and evaluate fouling resistant compressor coatings for Rolls Royce Allison 501-K Series gas turbines. The objective of these tests was to investigate the feasibility of reducing the rate of compressor fouling degradation and associated rate of specific fuel consumption (SFC) increase through the application of anti-fouling coatings. Code 9334 conducted a market investigation and selected coatings that best fit the test objective. The coatings selected were Sermalon for compressor stages 1 and 2 and Sermaflow S4000 for the remaining 12 compressor stages. Both coatings are manufactured by Sermatech International, are intended to substantially decrease blade surface roughness, have inert top layers, and contain an anti-corrosive aluminum-ceramic base coat. Sermalon contains a Polytetrafluoroethylene (PTFE) topcoat, a substance similar to Teflon, for added fouling resistance. Tests were conducted at the Philadelphia Land Based Engineering Site (LBES). Testing was first performed on the existing LBES 501-K17 gas turbine, which had a non-coated compressor. The compressor was then replaced by a coated compressor and the test was repeated. The test plan consisted of injecting a known amount of salt solution into the gas turbine inlet while gathering compressor performance degradation and fuel economy data for 0, 500, 1000, and 1250 KW generator load levels. This method facilitated a direct comparison of compressor degradation trends for the coated and non-coated compressors operating with the same turbine section, thereby reducing the number of variables involved. The collected data for turbine inlet, temperature, compressor efficiency, and fuel consumption were plotted as a percentage of the baseline conditions for each compressor. The results of each plot show a decrease in the rates of compressor degradation and SFC increase for the coated compressor compared to the non-coated compressor. Overall test results show that it is feasible to utilize anti-fouling compressor coatings to reduce the rate of specific fuel consumption increase associated with compressor performance degradation.


Author(s):  
Katsuyoshi Tada ◽  
Kei Inoue ◽  
Tomo Kawakami ◽  
Keijiro Saitoh ◽  
Satoshi Tanimura

Gas-turbine combined-cycle (GTCC) power generation is clean and efficient, and its demand will increase in the future from economic and social perspectives. Raising turbine inlet temperature is an effective way to increase combined cycle efficiency and contributes to global environmental conservation by reducing CO2 emissions and preventing global warming. However, increasing turbine inlet temperature can lead to the increase of NOx emissions, depletion of the ozone layer and generation of photochemical smog. To deal with this issue, MHPS (MITSUBISHI HITACHI POWER SYSTEMS) and MHI (MITSUBISHI HEAVY INDUSTRIES) have developed Dry Low NOx (DLN) combustion techniques for high temperature gas turbines. In addition, fuel flexibility is one of the most important features for DLN combustors to meet the requirement of the gas turbine market. MHPS and MHI have demonstrated DLN combustor fuel flexibility with natural gas (NG) fuels that have a large Wobbe Index variation, a Hydrogen-NG mixture, and crude oils.


Author(s):  
Hideto Moritsuka

In order to estimate the possibility to improve thermal efficiency of power generation use gas turbine combined cycle power generation system, benefits of employing the advanced gas turbine technologies proposed here have been made clear based on the recently developed 1500C-class steam cooling gas turbine and 1300C-class reheat cycle gas turbine combined cycle power generation systems. In addition, methane reforming cooling method and NO reducing catalytic reheater are proposed. Based on these findings, the Maximized efficiency Optimized Reheat cycle Innovative Gas Turbine Combined cycle (MORITC) Power Generation System with the most effective combination of advanced technologies and the new devices have been proposed. In case of the proposed reheat cycle gas turbine with pressure ratio being 55, the high pressure turbine inlet temperature being 1700C, the low pressure turbine inlet temperature being 800C, combined with the ultra super critical pressure, double reheat type heat recovery Rankine cycle, the thermal efficiency of combined cycle are expected approximately 66.7% (LHV, generator end).


Author(s):  
S. Can Gülen

Abstract There is very little doubt that there has been a noticeable advance in heavy-duty industrial gas turbine technology for utility scale electric power generation in the last decade. In keeping with the first six decades of the technology (roughly 1950 through 2010), the main drivers in increasing thermal efficiency and megawatt ratings have been increasing turbine inlet temperature and airflow. In accordance with the basic thermodynamic principles governing the underlying Brayton cycle, compressor pressure ratio kept pace with them. It is hard to quibble about the 40+ percent in rated thermal efficiency in simple cycle. If projected turbine inlet temperatures and cycle pressure ratios can be sustained in the field, current state-of-the-art in turbine hot gas path metallurgy, coatings and advanced film cooling techniques indeed support published ratings. Unfortunately, published combined cycle ratings are an altogether different matter. It is one thing to set the product line rating performance at an aggressive level with well-understood albeit optimistic assumptions such as very low water-cooled steam turbine condenser pressure with open-loop cooling. It is yet another thing to blatantly disregard fundamental laws of thermodynamics with outlandish performance ratings, which are unlikely to materialize even in the next decade or two cost-effectively (unless an unforeseen transformative step-change in technology materializes). In this paper, using fundamental thermodynamic arguments and detailed heat and mass balance simulations, it will be shown that some, if not all, OEM ratings are losing touch with reality.


2015 ◽  
Vol 137 (6) ◽  
Author(s):  
Thamir K. Ibrahim ◽  
M. M. Rahman

The performance enhancements and modeling of the gas turbine (GT), together with the combined cycle gas turbine (CCGT) power plant, are described in this study. The thermal analysis has proposed intercooler–reheated-GT (IHGT) configuration of the CCGT system, as well as the development of a simulation code and integrated model for exploiting the CCGT power plants performance, using the matlab code. The validation of a heavy-duty CCGT power plants performance is done through real power plants, namely, MARAFIQ CCGT plants in Saudi Arabia with satisfactory results. The results from this simulation show that the higher thermal efficiency of 56% MW, while high power output of 1640 MW, occurred in IHGT combined cycle plants (IHGTCC), having an optimal turbine inlet temperature about 1900 K. Furthermore, the CCGT system proposed in the study has improved power output by 94%. The results of optimization show that the IHGTCC has optimum power of 1860 MW and thermal efficiency of 59%. Therefore, the ambient temperatures and operation conditions of the CCGT strongly affect their performance. The optimum level of power and efficiency is seen at high turbine inlet temperatures and isentropic turbine efficiency. Thus, it can be understood that the models developed in this study are useful tools for estimating the CCGT power plant's performance.


Author(s):  
Hideto Moritsuka ◽  
Tomoharu Fujii ◽  
Takeshi Takahashi

The thermal efficiency of gas turbine combined cycle power generation plants increase significantly in accordance with turbine inlet temperature. Gas turbine combined cycle power plants operating at high turbine inlet temperature are popular as a main thermal power station among our electric power companies in Japan. Thus, gas turbine hot gas parts are working under extreme conditions which will strongly affect their lifetime as well as maintenance costs for repaired and replaced parts. To reduce the latter is of major importance to enhance cost effectiveness of the plant. This report describes a gas turbine maintenance management program of main hot gas parts (combustor chambers, transition peices, turbine 1st. stage nozzles and 1st. stage buckets) for management persons of gas turbine combined cycle power stations in order to obtain an optimal gas turbine maintenance schedule considering rotation, repair and replacement or exchange of those parts.


Author(s):  
M. Klohr ◽  
J. Schmidtke ◽  
S. Tschirren ◽  
P. Rihak

On 20 October 1993, the first ABB GT13E2 gas turbine was put into operation. This 165 MW class gas turbine achieves 35,7% thermal efficiency in single cycle application and up to 54,3% (according ISO standard 3977, Annexe F) in a three pressure system. An optimised turbine and compressor design along with the increased turbine inlet temperature, lead to improved efficiency and electrical output. A new concept for the combustor aimed at meeting the increasing demands on gas turbine emissions. The GT13E2 is equipped with the new single annular combustor and 72 of the ABB EV double cone burners. The commissioning and testing of the first GT13E2 was carried out at the Kawasaki Gas Turbine Research Center (KGRC) in Sodegaura City near Tokyo, Japan. The gas turbine was assembled with various measurement systems to monitor static and dynamic pressure, gas and metal temperature, expansion, vibration, velocity and emissions. The facility will be used during a 15 year joint test program by ABB and Kawasaki Heavy Industries (KHI) to obtain a sound database of operating experience for further improvements of the GT13E2 gas turbine. Therefore, mid 1994 a second test phase was conducted and early 1995 a third test period is scheduled. In parallel, the 2nd and 3rd GT13E2’s were commissioned and tested at the Deeside Combined Cycle Power Plant near Chester, Great Britain. In November 1994, the 4th GT13E2 at Lage Weide was successfully commissioned. This paper describes the operating experience with the GT13E2 during the first commissioning and test phases at KGRC and Deeside. The design features, the test facility, the instrumentation, the commissioning and test results are presented and discussed.


Sign in / Sign up

Export Citation Format

Share Document