Results From High Temperature Turbine Test on the HPT of the AGTJ-100A

Author(s):  
Masashi Arai ◽  
Kiyomi Teshima ◽  
Sunao Aoki ◽  
Hiroyuki Yamao

An experimental investigation was conducted through the use of a High Temperature Turbine Developing Unit (HTDU) having the same two stage turbine as the high pressure turbine (HPT) of the AGTJ-100A, to ascertain the aerodynamic performance, cooling characteristics and mechanical reliability. The test was performed in three phases, and the maximum turbine inlet temperature was about 1,573 K. The test results showed that turbine efficiency was 90.2 %, the level of metal temperature for nozzles and blades was as expected, and there was little trouble with the hot parts. This paper will present these test results.

1988 ◽  
Vol 110 (2) ◽  
pp. 251-258 ◽  
Author(s):  
S. Aoki ◽  
K. Teshima ◽  
M. Arai ◽  
H. Yamao

Phase II of the high-temperature turbine test was performed using the High-Temperature Developing Unit (HTDU). This unit has the same two stages as the high-pressure turbine of the AGTJ-100A reheat system. The purpose of the Phase II test was to investigate the potential of candidate technologies that may be applied to the advanced engine, the AGTJ-100B. Cooling characteristics of several cooling schemes for the first stage blades, and the performance of thermal barrier coating employed on the first stage nozzles and blades, were investigated. This paper presents the Phase II test results.


Author(s):  
Keisuke Makino ◽  
Ken-Ichi Mizuno ◽  
Toru Shimamori

NGK Spark Plug Co., Ltd. has been developing various silicon nitride materials, and the technology for fabricating components for ceramic gas turbines (CGT) using theses materials. We are supplying silicon nitride material components for the project to develop 300 kW class CGT for co-generation in Japan. EC-152 was developed for components that require high strength at high temperature, such as turbine blades and turbine nozzles. In order to adapt the increasing of the turbine inlet temperature (TIT) up to 1,350 °C in accordance with the project goals, we developed two silicon nitride materials with further unproved properties: ST-1 and ST-2. ST-1 has a higher strength than EC-152 and is suitable for first stage turbine blades and power turbine blades. ST-2 has higher oxidation resistance than EC-152 and is suitable for power turbine nozzles. In this paper, we report on the properties of these materials, and present the results of evaluations of these materials when they are actually used for CGT components such as first stage turbine blades and power turbine nozzles.


Author(s):  
Lucas Pawsey ◽  
David John Rajendran ◽  
Vassilios Pachidis

An unlocated shaft failure in the high pressure turbine spool of an engine may result in a complex orbiting motion along with rearward axial displacement of the high pressure turbine rotor sub-assembly. This is due to the action of resultant forces and limitations imposed by constraints such as the bearings and turbine casing. Such motion of the rotor following an unlocated shaft failure, results in the development of multiple contacts between the components of the rotor sub-assembly, the turbine casing, and the downstream stator casing. Typically, in the case of shrouded rotor blades, the tip region is in the form of a seal with radial protrusions called ‘fins’ between the rotor blade and the turbine casing. The contact between the rotor blade and the turbine casing will therefore result in excessive wear of the tip seal fins, resulting in changes in the geometry of the tip seal domain that affects the characteristics of the tip leakage vortex. The rotor sub-assembly with worn seals may also be axially displaced rearwards, and consequent to this displacement, changes in the geometry of the rotor blade may occur because of the contact between the rotor sub-assembly and the downstream stator casing. An integrated approach of structural analyses, secondary air system dynamics, and 3D CFD is adopted in the present study to quantify the effect of the tip seal damage and axial displacement on the aerodynamic performance of the turbine stage. The resultant geometry after wearing down of the fins in the tip seal, and rearward axial displacement of the rotor sub-assembly is obtained from LS-DYNA simulations. 3D RANS analyses are carried out to quantify the aerodynamic performance of the turbine with worn fins in the tip seal at three different axial displacement locations i.e. 0 mm, 10 mm and 15 mm. The turbine performance parameters are then compared with equivalent cases in which the fins in the tip seal are intact for the same turbine axial displacement locations. From this study it is noted that the wearing of tip seal fins results in reduced turbine torque, power output and efficiency, consequent to changes in the flow behaviour in the turbine passages. The reduction in turbine torque will result in the reduction of the terminal speed of the rotor during an unlocated shaft failure. Therefore, a design modification that can lead to rapid wearing of the fins in the tip seal after an unlocated shaft failure holds promise for the management of a potential over-speed event.


Author(s):  
M. W. Horner ◽  
A. Caruvana

Final component and technology verification tests have been completed for application to a 2600°F rotor inlet temperature gas turbine. These tests have proven the capability of combustor, turbine hot section, and IGCC fuel systems and controls to operate in a combined cycle plant burning a coal-derived gas fuel at elevated gas turbine inlet temperatures (2600–3000°F). This paper presents recent test results and summarizes the overall progress made during the DOE-HTTT Phase II program.


2021 ◽  
pp. 1-26
Author(s):  
Patrick René Jagerhofer ◽  
Marios Patinios ◽  
Tobias Glasenapp ◽  
Emil Goettlich ◽  
Federica Farisco

Abstract The imperative improvement in the efficiency of turbofan engines is commonly facilitated by increasing the turbine inlet temperature. This development has reached a point where also components downstream of the high-pressure turbine have to be adequately cooled. Such a component is the turbine center frame (TCF), known for a complex aerodynamic flow highly influenced by purge-mainstream interactions. The purge air, being injected through the wheelspace cavities of the upstream high-pressure turbine, bears a significant cooling potential for the TCF. Despite this, fundamental knowledge of the influencing parameters on heat transfer and film cooling in the TCF is still missing. This paper examines the influence of purge-to-mainstream blowing ratio, density ratio and purge swirl angle on heat transfer and film cooling in the TCF. The experiments are conducted in a sector-cascade test rig specifically designed for such heat transfer studies using infrared thermography and tailor-made flexible heating foils with constant heat flux. Three purge-to-mainstream blowing ratios and an additional no purge case are investigated. The purge flow is injected without swirl and also with engine-similar swirl angles. The purge swirl and blowing ratio significantly impact the magnitude and the spread of film cooling in the TCF. Increasing blowing ratios lead to an intensification of heat transfer. By cooling the purge flow, a moderate variation in purge-to-mainstream density ratio is investigated, and the influence is found to be negligible.


1996 ◽  
Vol 118 (4) ◽  
pp. 263-268 ◽  
Author(s):  
L. M. C. Gato ◽  
V. Warfield ◽  
A. Thakker

The paper describes an experimental investigation, and presents the results of the aerodynamic performance of a high-solidity Wells turbine for a wave power plant. A monoplane turbine of 0.6 m rotor diameter with guide vanes was built and tested. The tests were conducted in unidirectional steady airflow. Measurements taken include flow rate, pressure drop, torque, and rotational speed, as well as velocity and pressure distributions. Experimental results show that the presence of guide vanes can provide a remarkable increase in turbine efficiency.


Sign in / Sign up

Export Citation Format

Share Document