Dynamic Simulation of Organic Rankine Cycle-Assisted Ground-Source Heat Pump Based Micro-Cogeneration System in Cold Climates: A Case Study in Canada

Author(s):  
Wahiba Yaïci ◽  
Evgueniy Entchev ◽  
Michela Longo

Abstract As the energy needed for heating and cooling involves a substantial amount (> 80%) of residential energy utilisation in Canada, there is a demand for ultra-efficient energy systems for heating, cooling, and power generation. Two efficient systems to assist these systems are ground-source heat pumps (GSHPs) and organic Rankine cycles (ORCs). Of particular interest, this paper presents the integration of these two systems in a parallel configuration. A transient simulation model developed in TRNSYS program has been utilised to simulate the thermal performance of the combined ORC-GSHP based microco/trigeneration system. This later supplies heating and cooling to the residential load during the heating mode as required, with the capability to switch to a charging mode, where the ORC unit is directly coupled to the ground heat exchanger (GHE), which operates as a thermal energy storage and provides energy to the GSHP. The feasibility of this combined system configuration as well as its comparison with a conventional GSHP system are investigated for use in residential application in Ottawa, Canada temperature conditions. Results disclosed that the proposed micro-cogeneration system had the operating hours and performance of the GSHP improved by the addition of the ORC unit, resulting in about 11.8% reduction in hours in the colder city of Ottawa. The COP (coefficient of performance) of the GSHP system sustained a much higher value overall due to the addition of the ORC system to maintain the GHE storage temperature. In terms of net energy reduction between the conventional GSHP system and the ORC-assisted one, results revealed that Ottawa had energy usage reduction of 82.0%, demonstrating that the addition of an ORC to provide heating and recharge the GHE of a GSHP system has many advantages that could be accomplished by the end-user.

Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5705
Author(s):  
Wahiba Yaïci ◽  
Andres Annuk ◽  
Evgueniy Entchev ◽  
Michela Longo ◽  
Janar Kalder

In cold climatic regions such as those located across Canada, it is necessary to implement heating system technology that is ultra-efficient and that has near-zero rates of emissions. Such systems would satisfy consumers’ energy needs and also comply with environmental standards, especially because the systems would account for more than 80% of residential energy use. This paper investigates two complementary efficient systems that can support these heating systems; ground-source heat pumps (GSHPs) and organic Rankine cycle systems (ORCs). The study proposes to couple these two systems in a parallel configuration. A dynamic simulation model created in TRNSYS platform has been deployed to assess the performance of the combined ORC-GSHP based micro-cogeneration system. This former provides heating to a residential house during the heating mode as needed. It has the capacity to switch to a charging mode, during which the ORC system is directly coupled to the ground heat exchanger (GHE), which works as a thermal energy storage and supplies energy to the GSHP. The feasibility of this combined system arrangement, and its comparison with a conventional GSHP system are examined for use in residential buildings in three cities across the varied climatic regions within Canada, namely Edmonton (AB), Halifax (NS), and Vancouver (BC). Results showed that the proposed micro-cogeneration system recorded less energy use of over 80%. The addition of the ORC system had a definite effect on the performance of the GSHP in that it decreased the operating hours from 11–58% compared to the conventional GSHP case and maintained consistently higher COP values. These results may help to specify viable ORC-GSHP based micro-co/trigeneration systems in cold climatic applications and should be useful for prototype design and development.


Author(s):  
Leon M. Headings ◽  
Gregory N. Washington

The goal of this research is to develop a framework for replacing conventional heating and cooling systems with distributed, continuously and electrically controlled, building-integrated thermoelectric (BITE) heat pumps. The coefficient of performance of thermoelectric heat pumps increases as the temperature difference across them decreases and as the amplitude of temperature oscillations decreases. As a result, this research examines how thermal insulation and mass elements can be integrated with thermoelectrics as part of active multi-layer structures in order to minimize net energy consumption. In order to develop BITE systems, an explicit finite volume model was developed to model the dynamic thermal response of active multi-layer wall structures subjected to arbitrary boundary conditions (interior and exterior temperatures and interior heat loads) and control algorithms. Using this numerical model, the effects of wall construction on net system performance were examined. These simulation results provide direction for the ongoing development of BITE systems.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


2020 ◽  
Author(s):  
Eric Wagner ◽  
Benjamin McDaniel ◽  
Dragoljub Kosanovic

Ground-source heat pump (GSHP) systems have been implemented at large scales on several university campuses to provide heating and cooling. In this study, we test the idea that a GSHP system, as a replacement for an existing Combined Heat and Power (CHP) heating system coupled with conventional cooling systems, could reduce CO2 emissions, and provide a cost benefit to a university campus. We use the existing recorded annual heating and cooling loads supplied by the current system and an established technique of modeling the heat pumps and borehole heat exchangers (BHEs) using a TRNSYS model. The GSHP system is modeled to follow the parameters of industry standards and sized to provide an optimal balance of capital and operating costs. Results show that despite a decrease in heating and cooling energy usage and CO2 emissions are achieved, a significant increase in electric demand and purchased electricity result in an overall cost increase. These results highlight the need for thermal energy storage, onsite distributed energy resources and/or demand response in cases where electric heat pumps are used to help mitigate electric demand during peak periods.


Author(s):  
Birol I. Kilkis

Effective utilization of low-enthalpy energy resources in heating, ventilating, and air-conditioning (HVAC) of sustainable buildings require a careful optimization to assure the most economical coupling of HVAC systems with low-enthalpy energy resources. In one of the two separate prior studies an optimization algorithm for the optimal coupling of heat pumps and radiant panel heating and cooling systems was developed. In the second prior study an optimization algorithm for driving ground source heat pumps with wind turbines was developed. In this study these two algorithms were combined for a compound utilization of alternative energy resources. This paper describes the optimization algorithms, emphasizes their importance in achieving a cost effective combined application, and discusses the results obtained from the examples given.


Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2496 ◽  
Author(s):  
Laura Carnieletto ◽  
Borja Badenes ◽  
Marco Belliardi ◽  
Adriana Bernardi ◽  
Samantha Graci ◽  
...  

The design of ground source heat pumps is a fundamental step to ensure the high energy efficiency of heat pump systems throughout their operating years. To enhance the diffusion of ground source heat pump systems, two different tools are developed in the H2020 research project named, “Cheap GSHPs”: A design tool and a decision support system. In both cases, the energy demand of the buildings may not be calculated by the user. The main input data, to evaluate the size of the borehole heat exchangers, is the building energy demand. This paper presents a methodology to correlate energy demand, building typologies, and climatic conditions for different types of residential buildings. Rather than envelope properties, three insulation levels have been considered in different climatic conditions to set up a database of energy profiles. Analyzing European climatic test reference years, 23 locations have been considered. For each location, the overall energy and the mean hourly monthly energy profiles for heating and cooling have been calculated. Pre-calculated profiles are needed to size generation systems and, in particular, ground source heat pumps. For this reason, correlations based on the degree days for heating and cooling demand have been found in order to generalize the results for different buildings. These correlations depend on the Köppen–Geiger climate scale.


2019 ◽  
Vol 3 (2) ◽  

In the recent attempts to stimulate alternative energy sources for heating and cooling of buildings, emphasise has been put on utilisation of the ambient energy from ground source heat pump systems (GSHPs) and other renewable energy sources. Exploitation of renewable energy sources and particularly ground heat in buildings can significantly contribute towards reducing dependency on fossil fuels. The study was carried out at the Energy Research Institute (ERI), between September 2016 and November 2017. This paper highlights the potential energy saving that could be achieved through use of ground energy source. The main concept of this technology is that it uses the lower temperature of the ground (approximately <32°C), which remains relatively stable throughout the year, to provide space heating, cooling and domestic hot water inside the building area. The purpose of this study, however, is to examine the means of reducing of energy consumption in buildings, identifying GSHPs as an environmental friendly technology able to provide efficient utilisation of energy in the buildings sector, promoting the use of GSHPs applications as an optimum means of heating and cooling, and presenting typical applications and recent advances of the DX GSHPs. It is concluded that the direct expansion of GSHP are extendable to more comprehensive applications combined with the ground heat exchanger in foundation piles and the seasonal thermal energy storage from solar thermal collectors. This study highlights the energy problem and the possible saving that can be achieved through the use of the GSHP systems. This article discusses the principle of the ground source energy, varieties of GSHPs, and various developments.


2021 ◽  
Author(s):  
Ying Lam E. Law ◽  
Seth B. Dworkin

Ground source heat pumps (GSHPs) are an environmentally friendly alternative to conventional heating and cooling systems because of their high efficiency and low greenhouse gas emissions. The ground acts as a heat sink/source for the excess/required heat inside a building for cooling and heating modes, respectively. However, imbalance in heating and cooling needs can change ground temperature over the operating duration. This increase/decrease in ground temperature lowers system efficiency and causes the ground to foul—failing to accept or provide more heat. In order to ensure that GSHPs can operate to their designed conditions, thermal modelling is required to simulate the ground temperature during system operation. In addition, the borehole field layout can have a major impact on ground temperature. In this study, four buildings were studied—a hospital, fast-food restaurant, residence, and school, each with varying borehole configurations. Boreholes were modeled in a soil volume using finite-element methods and heating and cooling fluxes were applied to the borehole walls to simulate the GSHP operation. 20 years of operation were modelled for each building for 2x2, 4x4, and 2x8 borehole configurations. Results indicate that the borehole separation distance of 6 m, recommended by ASHRAE, is not always sufficient to prevent borehole thermal interactions. Benefits of using a 2x8 configuration as opposed to a 4x4 configuration, which can be observed because of the larger perimeter it provides for heat to dissipate to surrounding soil were quantified. This study indicates that it is important to carefully consider ground temperature during the operation of a GSHP. Borehole separation distances, layout, and hybridization should be studied to alleviate ground fouling problems.


Author(s):  
Abeer Osama Radwan

Nowadays global warming and thermal islands in modern cities are spending much energy on heating and cooling spaces. Geothermal energy considered a renewable energy technology for space heating and cooling. The ground source heat pumps (GSHPs) are increasingly interested in their expressive potential to reduce fossil fuel consumption and hence reduce greenhouse gases. Geothermal energy used for both electricity generation and direct use, depending on the temperature and the chemistry of the resources. Recently, direct utilization has varied significantly, and there are several methods available for temperatures typically ranging from 4°C up to 80°C. (Lund J.W., 2012). This paper presents a comprehensive literature-based review of ground source heat pump technology, cooling, and heating applications buildings to achieve precisely human thermal comfort. Subsequently, propose the influence factors of the system components that would undoubtedly reflect on the optimal design of the building. As a result, achieve precisely an integrated building.


2021 ◽  
pp. 103438
Author(s):  
Francesco Calise ◽  
Francesco Liberato Cappiello ◽  
Massimo Dentice d'Accadia ◽  
Fontina Petrakopoulou ◽  
Maria Vicidomini

Sign in / Sign up

Export Citation Format

Share Document