Heat Transfer Enhancement in a Horizontal Channel by the Addition of Curved Baffles

Author(s):  
J. L. Luviano ◽  
A. Hernandez ◽  
C. Rubio ◽  
D. Banerjee

This paper presents the heat transfer and fluid dynamics analysis of a horizontal channel formed by parallel plates with periodic insertions of heated blocks, having curved deflectors to direct the flow. The heat transfer coefficient investigated is compared with that of the horizontal channel without deflectors. The aim of the deflectors is to lead the fluid to the space between the heated blocks increasing the dynamics in this area. This zone will normally, without deflectors, become a stagnant fluid zone in which low energy transfer rate occurs. The results show that the heat transfer coefficient is larger as compared to that of the case without deflectors. The increment in the heat transfer coefficient is due primarily to the fluid motion stirred in the area between the heated block due to the deflectors. However, it must be pointed out. This implementation also increases the pressure drop in the channel.

2012 ◽  
Vol 134 (10) ◽  
Author(s):  
Ting-Yu Lin ◽  
Satish G. Kandlikar

The effect of structured roughness on the heat transfer of water flowing through minichannels was experimentally investigated in this study. The test channels were formed by two 12.7 mm wide × 94.6 mm long stainless steel strips. Eight structured roughness elements were generated using a wire electrical discharge machining (EDM) process as lateral grooves of sinusoidal profile on the channel walls. The height of the roughness structures ranged from 18 μm to 96 μm, and the pitch was varied from 250 μm to 400 μm. The hydraulic diameter of the rectangular flow channels ranged from 0.71 mm to 1.87 mm, while the constricted hydraulic diameter (obtained by using the narrowest flow gap) ranged from 0.68 mm to 1.76 mm. After accounting for heat losses from the edges and end sections, the heat transfer coefficient for smooth channels was found to be in good agreement with the conventional correlations in the laminar entry region as well as in the laminar fully developed region. All roughness elements were found to enhance the heat transfer. In the ranges of parameters tested, the roughness element pitch was found to have almost no effect, while the heat transfer coefficient was significantly enhanced by increasing the roughness element height. An earlier transition from laminar to turbulent flow was observed with increasing relative roughness (ratio of roughness height to hydraulic diameter). For the roughness element designated as B-1 with a pitch of 250 μm, roughness height of 96 μm and a constricted hydraulic diameter of 690 μm, a maximum heat transfer enhancement of 377% was obtained, while the corresponding friction factor increase was 371% in the laminar fully developed region. Comparing different enhancement techniques reported in the literature, the highest roughness element tested in the present work resulted in the highest thermal performance factor, defined as the ratio of heat transfer enhancement factor (over smooth channels) and the corresponding friction enhancement factor to the power 1/3.


2021 ◽  
Vol 874 ◽  
pp. 165-170
Author(s):  
Sri Wuryanti ◽  
Tina Mulya Gantina ◽  
Indriyani

The research objective is to assemble a convection test system which acts as a heat exchanger (HE) and test its applicability using ethylene glycol. A Double Pipe (DP)-type HE consists of an inner pipe surrounded by an outer pipe (annulus) whereas a Coil-type HE composed of a coil surrounded by an outer pipe. Water flows through the outer pipe in both types of HE, while ethylene glycol flows through the inner piper or coil. HE in combination with other components (such as) forms a convection test system. The applicability of the system was tested to determine the heat transfer coefficient of ethylene glycol in a DP-type and Coil-type HEs. After that, the heat transfer rate was calculated and compared. The results show that the heat transfer coefficient in the DP-type HE is the lowest at 12.2 W/m2 oC and the highest at 26.8 W/m2 oC; and the corresponding heat transfer rate is the lowest at 8.3 W and the highest is 56.3 W. In comparison, for Coil-type HE, the lowest heat transfer coefficient is 38.9 W/m2 oC and the highest is 66.2 W/m2 oC which correspond to the heat transfer rate 19.9 W at the lowest and 225 W at the highest.


2012 ◽  
Vol 16 (2) ◽  
pp. 469-480 ◽  
Author(s):  
Hosseinali Soltanipour ◽  
Parisa Choupani ◽  
Iraj Mirzaee

This paper presents a numerical investigation of heat transfer augmentation using internal longitudinal ribs and ?-Al2O3/ water nanofluid in a stationary curved square duct. The flow is assumed 3D, steady, laminar, and incompressible with constant properties. Computations have been done by solving Navier-Stokes and energy equations utilizing finite volume method. Water has been selected as the base fluid and thermo- physical properties of ?- Al2o3/ water nanofluid have been calculated using available correlations in the literature. The effects of Dean number, rib size and particle volume fraction on the heat transfer coefficient and pressure drop have been examined. Results show that nanoparticles can increase the heat transfer coefficient considerably. For any fixed Dean number, relative heat transfer rate (The ratio of the heat transfer coefficient in case the of ?- Al2o3/ water nanofluid to the base fluid) increases as the particle volume fraction increases; however, the addition of nanoparticle to the base fluid is more useful for low Dean numbers. In the case of water flow, results indicate that the ratio of heat transfer rate of ribbed duct to smooth duct is nearly independent of Dean number. Noticeable heat transfer enhancement, compared to water flow in smooth duct, can be achieved when ?-Al2O3/ water nanofluid is used as the working fluid in ribbed duct.


2008 ◽  
Author(s):  
Bolaji O. Olayiwola ◽  
Gerhard Schaldach ◽  
Peter Walzel

Experimental and CFD studies were performed to investigate the enhancement of convective heat transfer in a laminar cooling system using flow pulsation in a flat channel with series of regular spaced fins. Glycerol-water mixtures with dynamic viscosities in the range of 0.001 kg/ms–0.01 kg/ms were used. A steady flow Reynolds number in the laminar range of 10 < Re < 1200 was studied. The amplitudes of the applied pulsations are in the range of 0.25 < A < 0.55 mm and the frequency range is 10 < f < 60 Hz. Two different cooling devices with active length L = 450 mm and 900 mm were investigated. CFD simulations were performed on a parallel-computer (Linux-cluster) using the software suit CFX11 from ANSYS GmbH, Germany. The rate of cooling was found to be significant at moderate low net flow rates. In general, no significant heat transfer enhancement at very low and high flow rates was obtained in compliance with the experimental data. The heat transfer coefficient was found to increase with increasing Prandtl number Pr at constant oscillation Reynolds number Reosc whereas the ratio of the hydraulic diameter to the length of the channel dh/L has insignificant effect on the heat transfer coefficient. This is due to enhanced fluid mixing. CFD results allow for performance predictions of different geometries and flow conditions.


2021 ◽  
Vol 7 (1) ◽  
pp. 21-28
Author(s):  
Rahul Kunar ◽  
Dr Sukul Lomash

The heat transfer from surface may in general be enhanced by increasing the heat transfer coefficient between a surface and its surrounding or by increasing heat transfer area of the surface or by both. The main objective of the study and calculate the total heat transfer coefficient. Improve the heat transfer rate by using ANSYS CFD. During the CFD calculations of the flow in internally ribbed tubes. And calculated the temperature distribution and pressure inside the tube by using ansys. The model was created using CatiaV5 and meshed with Ansys, and the flow analysis is done with Ansys 19.2. The results showing that the heat transfer is increased. The enthalpy and temperature increase with flow is advancing when compare with normal boiler tube. In this study the total heat transfer rate of the pipe increase with the increase the rib height. Total heat transfer rate increase up to 7.7kw. The study show that the improvement in furnace heat transfer can be achieved by changing the internal rib design.


2020 ◽  
Vol 142 (5) ◽  
Author(s):  
Lin Ye ◽  
Cun-Liang Liu ◽  
Dao-En Zhou ◽  
Hui-Ren Zhu

Abstract The heat transfer coefficient of cylindrical holes fed by varying internal cross-flow channels with different cross-flow Reynolds numbers Rec is experimentally studied on a low-speed flat-plate facility. Three coolant cross flow cases, including a smooth case and two ribbed cases with 45/135-deg ribs, are studied at Rec = 50,000, and 100,000 with varying blowing ratios M of 0.5, 1.0, and 2.0. A transient liquid-crystal (LC) measurement technique is used to determine the heat transfer coefficient. At lower M, the heat transfer enhancement regions are asymmetrical for the smooth and 45-deg cases. The asymmetrical vortex is more pronounced with increasing cross-flow direction velocity, resulting in a more skewed distribution at Rec = 100,000. Conversely, the contours are laterally symmetric in the 135-deg case at varying Rec. A fork-shaped trend with a relatively high heat transfer coefficient appears upstream, and the increases in the heat transfer in the 135-deg cases are lower than those in the 45-deg cases. As M increases to 2.0, the vortex intensity increases, resulting in a stronger scouring effect upstream, especially at large Rec. The range and degree are affected by Rec at M = 2.0. The core of the heat transfer enhancement is skewed to the −Y side for both cases.


1970 ◽  
Vol 92 (4) ◽  
pp. 616-620 ◽  
Author(s):  
R. E. Holmes ◽  
A. J. Chapman

The condensation of Freon-114 in the presence of a nonuniform, alternating, 60-cycle, electric field was examined experimentally. The condensing surface was a grounded, cooled flat plate, and the electric field was produced by applying a voltage to a second plate placed above the first. Voltages up to 60 kv were imposed, and nonuniformities in the field were created by varying the angle between the plates. Analytical predictions were made of the expected heat-transfer rate, and reasonable agreement with the experimental data was obtained for voltages less than 40 kv. Above 40 kv the results were unpredictable, but increases in the heat-transfer coefficient as high as ten times that for no field were obtained.


1986 ◽  
Vol 108 (4) ◽  
pp. 841-847 ◽  
Author(s):  
A. Nakayama ◽  
H. Koyama

Calculations were carried out for fully developed turbulent flows within ducts of cross-shaped cross section using the numerical method based on the pressure correction method developed by Patankar and Spalding. The Reynolds stress driven secondary flows were simulated successfully by Launder and Ying’s algebraic stress model coupled to the k–ε turbulence model. A parametric study was made on the friction and heat transfer characteristics in terms of the parameter α associated with the decrease in the cross-sectional area, namely, α = 0 for a square duct, and α → 1 for infinite parallel plates. Through performance evaluations, it has been found that both the Reynolds analogy factor and the heat transfer coefficient under equal pumping power decrease slightly, while the heat transfer coefficient obtained with equal mass flow rate increases appreciably with α, suggesting effective turbulent heat transfer within ducts of cross-shaped cross section.


2019 ◽  
Vol 22 (1) ◽  
pp. 44-54 ◽  
Author(s):  
Hasan S. Majdi ◽  
Hussein A. Alabdly ◽  
Muayad F. Hamad ◽  
Basim Obaid Hasan ◽  
Mustafa M. Hathal

Both surface extension and nanofluid methods were used to enhance the heat transfer in a double pipe heat exchanger under turbulent flow conditions. Aluminum oxide nanoparticles were used with different concentrations(0.6-3 g/l)in hot water to increase the heat transfer rate on smooth tube and circular fins tube for a range of Reynolds number4240-19790. The simulation was also performed to predict the heat transfer coefficient and temperature profile for selected conditions in which COMSOL Multiphysics is used. The experimental results revealed that the heat transfer enhancement by both circular fin and nanofluid exhibited an increasing trend with Reynolds number and nanofluid concentration. The conjoint effect of Al2O3 of 3 g/l concentration and circular fin provided largest heat transfer enhancement of 53% for the highest Re investigated. Simulation results showed reasonable agreement with the experimental values of heat transfer coefficient. The simulation showed that the presence of nanofluid on finned surface influenced the temperature profile indicating the increased heat transfer rate.


Author(s):  
V T Perarasu ◽  
M Arivazhagan ◽  
P Sivashanmugam

Heat transfer studies in a coiled agitated vessel with varying heat input is presented using two agitators namely propeller and disk turbine. Heat transfer rate increases with agitator speed for both the agitators for a given heat input. The heat transfer coefficient also increases with heat input for a given agitator speed for turbine agitator for all the heat inputs, whereas for propeller it is increasing up to a certain value and then decreases. The heat transfer coefficient (heat transfer rate) for turbine agitator is higher than that for propeller for all heat inputs. Empirical correlations separately were formed for each agitator and found to fit the experimental values within range of ±15% for both the agitators.