A Risk Approach for Distribution Pipeline Systems

Author(s):  
James Mihell ◽  
Chad Augustine ◽  
Zaheed Hasham ◽  
Keith Leewis

Unlike the circumstance associated with transmission pipelines, where variables that are attributes of risk are typically widely available in GIS systems or in other databases that are geo-referenced to linear assets, risk data for distribution systems are not typically linearly referenced to what is essentially a network system. Therefore the manner in which risk is calculated and displayed for distribution systems must differ significantly from the way these functions are performed on transmission pipelines. In distribution systems, failure (defined as the loss of containment) and the contributors to the likelihood of failure, is often highly correlated to system-specific circumstances, such as type of material used, installation era, and operating environment. These correlations between cause-and-effect as they relate to failure likelihood in distribution systems are not widely recognized on a universal basis, such as they might be in transmission pipeline environments, but are typically unique to each operating system. Because system data for distribution networks is not typically available in a manner that can be linearly geo-referenced to pipeline coordinates the way it is for transmission systems, the convention of mapping risk to pipeline dynamic segments as a function of risk attributes that exist within those dynamic segments is not achievable for distribution systems the way that it is for transmission systems. Therefore, the most effective strategy for performing risk assessments in distribution systems is to create a database in which existing incident data can be correlated to system attributes, and then to use those correlations to create cause-and-effect relationships between system attributes and failure likelihood. Consequences are characterized in terms of the operating environment (e.g., wall-to-wall, residential, etc.), leak magnitude, type of facility (mains vs. service lines), and special mitigating or exacerbating factors, such as availability of excess flow valves, or the presence of inside meters. A risk assessment methodology has been developed that accommodates the above constraints and that meets the stated objectives, and which is well-suited to the distribution system data infrastructure that is typical of most operators. Because the risk assessment approach leverages existing databases and incident reporting structures, it lends itself to automation, and re-evaluation on a regular basis. Reporting is facilitated by a ‘heat map’, which provides immediate insight as to the drivers of risk for each system sub-group having similar design, materials, and operating characteristics.

Electricity ◽  
2021 ◽  
Vol 2 (2) ◽  
pp. 187-204
Author(s):  
Gian Giuseppe Soma

Nowadays, response to electricity consumption growth is mainly supported by efficiency; therefore, this is the new main goal in the development of electric distribution networks, which must fully comply with the system’s constraints. In recent decades, the issue of independent reactive power services, including the optimal placement of capacitors in the grid due to the restructuring of the electricity industry and the creation of a competitive electricity market, has received attention from related companies. In this context, a genetic algorithm is proposed for optimal planning of capacitor banks. A case study derived from a real network, considering the application of suitable daily profiles for loads and generators, to obtain a better representation of the electrical conditions, is discussed in the present paper. The results confirmed that some placement solutions can be obtained with a good compromise between costs and benefits; the adopted benefits are energy losses and power factor infringements, taking into account the network technical limits. The feasibility and effectiveness of the proposed algorithm for optimal placement and sizing of capacitor banks in distribution systems, with the definition of a suitable control pattern, have been proved.


2021 ◽  
Vol 11 (10) ◽  
pp. 4509
Author(s):  
Anna Rita Di Fazio ◽  
Chiara Risi ◽  
Mario Russo ◽  
Michele De Santis

This paper addresses the problem of optimizing the voltage profile of radially-operated distribution systems by acting on the active and reactive powers provided by distributed energy resources (DERs). A novel voltage optimization procedure is proposed by adopting a decentralized control strategy. To this aim, a centralized voltage optimization problem (VOP), minimizing the distance of all the nodal voltages from their reference values, is firstly formulated as a strictly-convex quadratic program. Then, the centralized VOP is rewritten by partitioning the network into voltage control zones (VCZs) with pilot nodes. To overcome the lack of strictly convexity determined by the reduction to the pilot nodes, the dual centralized VOP working on the augmented Lagrangian function is reformulated and iteratively solved by the method of multipliers. Finally, a fully-distributed VOP solution is obtained by applying a distributed algorithm based on the auxiliary problem principle, which allows for solving in each VCZ a quadratic programming problem of small dimension and to drive the VCZ solutions toward the overall optimum by an iterative coordination process that requires to exchange among the VCZs only scalar values. The effectiveness and feasibility of the proposed method have been demonstrated via numerical tests on the IEEE 123-bus system.


Author(s):  
Sayed Mir Shah Danish ◽  
Mikaeel Ahmadi ◽  
Atsushi Yona ◽  
Tomonobu Senjyu ◽  
Narayanan Krishna ◽  
...  

AbstractThe optimal size and location of the compensator in the distribution system play a significant role in minimizing the energy loss and the cost of reactive power compensation. This article introduces an efficient heuristic-based approach to assign static shunt capacitors along radial distribution networks using multi-objective optimization method. A new objective function different from literature is adapted to enhance the overall system voltage stability index, minimize power loss, and to achieve maximum net yearly savings. However, the capacitor sizes are assumed as discrete known variables, which are to be placed on the buses such that it reduces the losses of the distribution system to a minimum. Load sensitive factor (LSF) has been used to predict the most effective buses as the best place for installing compensator devices. IEEE 34-bus and 118-bus test distribution systems are utilized to validate and demonstrate the applicability of the proposed method. The simulation results obtained are compared with previous methods reported in the literature and found to be encouraging.


Water ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 131
Author(s):  
Jezabel D. Bianchotti ◽  
Melina Denardi ◽  
Mario Castro-Gama ◽  
Gabriel D. Puccini

Sectorization is an effective technique for reducing the complexities of analyzing and managing of water systems. The resulting sectors, called district metering areas (DMAs), are expected to meet some requirements and performance criteria such as minimum number of intervention, pressure uniformity, similarity of demands, water quality and number of districts. An efficient methodology to achieve all these requirements together and the proper choice of a criteria governing the sectorization is one of the open questions about optimal DMAs design. This question is addressed in this research by highlighting the advantages of three different criteria when applied to real-word water distribution networks (WDNs). To this, here it is presented a two-stage approach for optimal design of DMAs. The first stage, the clustering of the system, is based on a Louvain-type greedy algorithm for the generalized modularity maximization. The second stage, the physical dividing of the system, is stated as a two-objective optimization problem that utilises the SMOSA version of simulated annealing for multiobjective problems. One objective is the number of isolation valves whereas for the second objective three different performance indices (PIs) are analyzed and compared: (a) standard deviation, (b) Gini coefficient and (c) loss of resilience. The methodology is applied to two real case studies where the first two PIs are optimized to address similar demands among DMAs. The results demonstrate that the proposed method is effective for sectorization into independent DMAs with similar demands. Surprisingly, it found that for the real studied systems, loss of resilience achieves better performance for each district in terms of pressure uniformity and demand similarity than the other two specific performance criteria.


DYNA ◽  
2015 ◽  
Vol 82 (192) ◽  
pp. 60-67 ◽  
Author(s):  
John Edwin Candelo-Becerra ◽  
Helman Hernández-Riaño

<p>Distributed generation (DG) is an important issue for distribution networks due to the improvement in power losses, but the location and size of generators could be a difficult task for exact techniques. The metaheuristic techniques have become a better option to determine good solutions and in this paper the application of a bat-inspired algorithm (BA) to a problem of location and size of distributed generation in radial distribution systems is presented. A comparison between particle swarm optimization (PSO) and BA was made in the 33-node and 69-node test feeders, using as scenarios the change in active and reactive power, and the number of generators. PSO and BA found good results for small number and capacities of generators, but BA obtained better results for difficult problems and converged faster for all scenarios. The maximum active power injections to reduce power losses in the distribution networks were found for the five scenarios.</p>


2011 ◽  
Vol 11 (4-5) ◽  
pp. 731-747 ◽  
Author(s):  
MASSIMILIANO CATTAFI ◽  
MARCO GAVANELLI ◽  
MADDALENA NONATO ◽  
STEFANO ALVISI ◽  
MARCO FRANCHINI

AbstractThis paper presents a new application of logic programming to a real-life problem in hydraulic engineering. The work is developed as a collaboration of computer scientists and hydraulic engineers, and applies Constraint Logic Programming to solve a hard combinatorial problem. This application deals with one aspect of the design of a water distribution network, i.e., the valve isolation system design. We take the formulation of the problem by Giustolisi and Savić (2008 Optimal design of isolation valve system for water distribution networks. InProceedings of the 10th Annual Water Distribution Systems Analysis Conference WDSA2008, J. Van Zyl, A. Ilemobade, and H. Jacobs, Eds.) and show how, thanks to constraint propagation, we can get better solutions than the best solution known in the literature for the Apulian distribution network. We believe that the area of the so-calledhydroinformaticscan benefit from the techniques developed in Constraint Logic Programming and possibly from other areas of logic programming, such as Answer Set Programming.


2003 ◽  
Vol 3 (1-2) ◽  
pp. 209-214 ◽  
Author(s):  
J. Menaia ◽  
S.T. Coelho ◽  
A. Lopes ◽  
E. Fonte ◽  
J. Palma

Understanding chlorine residual decay kinetics and the factors that influence them are essential for such current tasks as siting chlorination facilities, dosage optimisation, choice of sampling locations and frequencies, and general design and operational control of drinking water networks, increasingly accomplished with the help of simulation models. Available constants for bulk chlorine decay are typically determined under static conditions. However, as for all fast reactions in water flows, chlorine consumption rates in drinking water pipes may be influenced by the existing mixing regimes, a function of flow turbulence, which is primarily controlled by flow velocity and pipe diameter. Flow velocities vary greatly in space and time in water transmission and distribution systems; pipe diameters are seldom uniform. Although both variables are readily available in the currently available network analysis simulators that implement chlorine models, such variations are not accounted for. Instead, a single preset decay rate constant is generally used for describing chlorine residual consumption throughout an entire system. In addition to highlighting how negligible PVC pipe wall chlorine consumption is, as such, this paper presents experimental evidence of a significant correlation between pipe flow velocity and bulk chlorine decay rates, and proposes a simple but effective approach to implement this dependency in current simulators.