Improvements in the Prediction of the Wave Making Resistance From Potential Flow by Using Transverse Wave Cut Methods

2015 ◽  
Author(s):  
Johannes Will ◽  
Anja Kömpe

The reliable and correct determination of the wave resistance is the key to an efficient ship design, as the wave resistance is one on the major factors concerning building and operational costs. In this paper the authors present a new approach to transverse wave cut analysis to overcome the major shortcoming of the resistance prediction from potential flow: a numerically stable and physically sound estimate for the magnitude of the wave making resistance.

2018 ◽  
Vol 383 ◽  
pp. 23-30 ◽  
Author(s):  
Bengü Tas Kavakbasi ◽  
Igor S. Golovin ◽  
Aloke Paul ◽  
Sergiy V. Divinski

Diffusion couple technique is an efficient tool for the estimating the chemical diffusion coefficients. Typical experimental uncertainties of the composition profile measurements complicate a correct determination of the interdiffusion coefficients via the standard Boltzmann-Matano, Sauer-Freise or the den Broeder methods, especially for systems with a strong compositional dependence of the interdiffusion coefficient. A new approach for reliable fitting of the experimental profiles with an improved behavior at both ends of the diffusion couple is proposed and tested against the experimental data on chemical diffusion in the system Fe-Ga. An extension of the approach for reliable description of the up-hill diffusion phenomenon in multicomponent systems is presented.


2017 ◽  
Vol 30 (1) ◽  
pp. 273-289
Author(s):  
Anmari Meerkotter

The Constitutional Court (CC) judgment of Lee v Minister of Correction Services 2013 2SA 144 (CC) is a recent contribution to transformative constitutional jurisprudence in the field of the law of delict. This matter turned on the issue of factual causation in the context of wrongful and negligent systemic omissions by the state. In this case note, I explore the law relating to this element of delictual liability with specific regard to the traditional test for factual causation – the conditio sine qua non (‘but-for’) test. In particular, I note the problems occasioned by formalistic adherence to this test in the context of systemic state omissions as evidenced by the SCA judgment in the same matter. I also consider the manner in which English courts have addressed this problem. Thereafter, I analyse the CC’s broader approach to the determination of factual causation as one based on common sense and justice. I argue that this approach endorses a break from a formalistic application of the test and constitutes a step towards an approach which resonates with the foundational constitutional values of freedom, dignity and equality. Furthermore, it presents an appropriate solution to the problems associated with factual causation where systemic omissions are concerned. I then consider the transformative impact of the Lee judgment. In particular, I argue that the broader enquiry favoured by the CC facilitates the realisation of constitutionally guaranteed state accountability, and amounts to an extension of the existing norm of accountability jurisprudence. Hence, I contend that the judgment presents a further effort by the Constitutional Court to effect wholesale the constitutionalisation of the law of delict, as well as a vindicatory tool to be used by litigants who have been adversely affected by systemic state omissions.


Author(s):  
Romain Desplats ◽  
Timothee Dargnies ◽  
Jean-Christophe Courrege ◽  
Philippe Perdu ◽  
Jean-Louis Noullet

Abstract Focused Ion Beam (FIB) tools are widely used for Integrated Circuit (IC) debug and repair. With the increasing density of recent semiconductor devices, FIB operations are increasingly challenged, requiring access through 4 or more metal layers to reach a metal line of interest. In some cases, accessibility from the front side, through these metal layers, is so limited that backside FIB operations appear to be the most appropriate approach. The questions to be resolved before starting frontside or backside FIB operations on a device are: 1. Is it do-able, are the metal lines accessible? 2. What is the optimal positioning (e.g. accessing a metal 2 line is much faster and easier than digging down to a metal 6 line)? (for the backside) 3. What risk, time and cost are involved in FIB operations? In this paper, we will present a new approach, which allows the FIB user or designer to calculate the optimal FIB operation for debug and IC repair. It automatically selects the fastest and easiest milling and deposition FIB operations.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3070
Author(s):  
Sebastian Iwaszenko ◽  
Jakub Munk ◽  
Stefan Baron ◽  
Adam Smoliński

Modern dentistry commonly uses a variety of imaging methods to support diagnosis and treatment. Among them, cone beam computed tomography (CBCT) is particularly useful in presenting head structures, such as the temporomandibular joint (TMJ). The determination of the morphology of the joint is an important part of the diagnosis as well as the monitoring of the treatment results. It can be accomplished by measurement of the TMJ gap width at three selected places, taken at a specific cross-section. This study presents a new approach to these measurements. First, the CBCT images are denoised using curvilinear methods, and the volume of interest is determined. Then, the orientation of the vertical cross-section plane is computed based on segmented axial sections of the TMJ head. Finally, the cross-section plane is used to determine the standardized locations, at which the width of the gap between condyle and fossa is measured. The elaborated method was tested on selected TMJ CBCT scans with satisfactory results. The proposed solution lays the basis for the development of an autonomous method of TMJ index identification.


Polymers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 2412
Author(s):  
Inés Ferrer ◽  
Ariadna Manresa ◽  
José Alberto Méndez ◽  
Marc Delgado-Aguilar ◽  
Maria Luisa Garcia-Romeu

Ultrasonic molding (USM) is a good candidate for studying the plasticization of polymer mixtures or other composite materials due to either the little amount of material needed for processing, low waste or the needed low pressure and residence time of the mold. Thus, the novelty of this research is the capability of USM technology to process PLA/PCL blends and their corresponding neat materials, encompassing all the production stages, from raw material to the final specimen. The major findings of the work revealed that the thermal properties of the blends were not affected by the USM process, although the crystallinity degree experienced variations, decreasing for PLA and increasing for PCL, which was attributed to the crystallization rate of each polymer, the high process speed, the short cooling time and the small particle size. The employed ultrasonic energy increased the molecular weight with low variations through the specimen. However, the degradation results aligned with the expected trend of these material blends. Moreover, this study also showed the effect pellet shape and dimensions have over the process parameters, as well as the effect of the blend composition. It can be concluded that USM is a technology suitable to successfully process PLA/PCL blends with the correct determination of process parameter windows.


Author(s):  
Robert Skov ◽  
David R Lonsway ◽  
Jesper Larsen ◽  
Anders Rhod Larsen ◽  
Jurgita Samulioniené ◽  
...  

Abstract Objectives Correct determination of penicillin susceptibility is pivotal for using penicillin in the treatment of Staphylococcus aureus infections. This study examines the performance of MIC determination, disc diffusion and a range of confirmatory tests for detection of penicillin susceptibility in S. aureus. Methods A total of 286 consecutive penicillin-susceptible S. aureus blood culture isolates as well as a challenge set of 62 MSSA isolates were investigated for the presence of the blaZ gene by PCR and subjected to penicillin-susceptibility testing using broth microdilution MIC determination, disc diffusion including reading of the zone edge, two nitrocefin tests and the cloverleaf test. Results Using PCR-based detection of blaZ as the gold standard, both broth microdilution MIC testing and disc diffusion testing resulted in a relatively low accuracy (82%–93%) with a sensitivity ranging from 49%–93%. Among the confirmatory tests, the cloverleaf test performed with 100% accuracy, while zone edge interpretation and nitrocefin-based tests increased the sensitivity of β-lactamase detection to 96%–98% and 82%–96% when using MIC determination or disc diffusion as primary test, respectively. Conclusions This investigation showed that reliable and accurate detection of β-lactamase production in S. aureus can be obtained by MIC determination or penicillin disc diffusion followed by interpretation of the zone edge as a confirmatory test for apparently penicillin-susceptible isolates. The more cumbersome cloverleaf test can also be used. Nitrocefin-based tests should not be used as the only test for confirmation of a presumptive β-lactamase-negative isolate.


Sign in / Sign up

Export Citation Format

Share Document