Hemodynamic Investigation of Flow in the Normal Portal Vein

Author(s):  
Stephanie M. George ◽  
Diego R. Martin ◽  
Don P. Giddens

Cirrhosis is the twelfth leading cause of death in the United States (1). Previous studies have compared portal vein blood flow and velocity in normal subjects and patients with varying results (2–5). In comparing grades of cirrhosis, based on the “Child-Pugh” score, portal flow was significantly affected as the degree of cirrhosis increased (2–4). These previous studies have used a variety of imaging methods; the most common being Doppler Ultrasound (2–5). The use of Magnetic Resonance Imaging (MRI) and phase contrast (PC) – MRI has not been used extensively to study liver hemodynamics. When compared to ultrasound, MRI is often superior in providing anatomical and hemodynamic information. There has also been no in depth study of normal portal vein hemodynamics, an important step for understanding changes due to cirrhosis. This study seeks to preliminarily characterize normal portal venous hemodynamics in a small number of subjects utilizing both MRI and computational fluid dynamics (CFD). The long term clinical objective is to develop non-invasive diagnostic methods to evaluate and monitor the progression of cirrhosis in patients with chronic liver disease.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Seyed-Ahmad Ahmadi ◽  
Theresa Marie Raiser ◽  
Ria Maxine Rühl ◽  
Virginia Lee Flanagin ◽  
Peter zu Eulenburg

AbstractBrain atlases and templates are core tools in scientific research with increasing importance also in clinical applications. Advances in neuroimaging now allowed us to expand the atlas domain to the vestibular and auditory organ, the inner ear. In this study, we present IE-Map, an in-vivo template and atlas of the human labyrinth derived from multi-modal high-resolution magnetic resonance imaging (MRI) data, in a fully non-invasive manner without any contrast agent or radiation. We reconstructed a common template from 126 inner ears (63 normal subjects) and annotated it with 94 established landmarks and semi-automatic segmentations of all relevant macroscopic vestibular and auditory substructures. We validated the atlas by comparing MRI templates to a novel CT/micro-CT atlas, which we reconstructed from 21 publicly available post-mortem images of the bony labyrinth. Templates in MRI and micro-CT have a high overlap, and several key anatomical measures of the bony labyrinth in IE-Map are in line with micro-CT literature of the inner ear. A quantitative substructural analysis based on the new template, revealed a correlation of labyrinth parameters with total intracranial volume. No effects of gender or laterality were found. We provide the validated templates, atlas segmentations, surface meshes and landmark annotations as open-access material, to provide neuroscience researchers and clinicians in neurology, neurosurgery, and otorhinolaryngology with a widely applicable tool for computational neuro-otology.


1995 ◽  
Vol 73 (04) ◽  
pp. 592-596 ◽  
Author(s):  
Sabina Villalta ◽  
Paolo Prandoni ◽  
Alberto Cogo ◽  
Paola Bagatella ◽  
Andrea Piccioli ◽  
...  

SummaryBackground. Despite the availability of several diagnostic methods for the detection of deep-vein thrombosis (DVT), the identification of previous episodes of DVT remains a diagnostic challenge.Study objective. To assess the reliability of a combination of a standardized clinical score with three non-invasive tests: compression ultrasonography (CUS), Doppler ultrasound (DUS), and photoplethysmography (PPG), in determining the presence or the absence of previous proximal DVT.Methods. One hundred consecutive unselected outpatients were identified, who had undergone contrast venography six to nine years previously because of the clinical suspicion of DVT (confirmed in 43). They were blindly reinvestigated by a panel of trained operators unaware of venography results. They underwent a clinical evaluation of the lower limb, by applying a standardized score to five symptoms and six signs (grading each item from 0 to 3); a PPG test to determine the venous refilling time; a DUS test to determine the venous reflux separately in the common femoral and the popliteal vein; and a CUS test to determine vein compressibility in the same regions.Results. An abnormal CUS test and/or the demonstration of venous reflux in the popliteal region and/or a high clinical score (≥ 8) identified twenty-four of the 43 (56%) DVT + patients with a specificity of 89%. The combination of normal CUS with the absence of venous reflux in both the common femoral and popliteal vein and a low clinical score excluded previous thrombosis in 45 (79%) of the 57 DVT- patients (negative predictive value, 78%). Abnormal venous reflux in the isolated common femoral vein did not reliably predict the presence or absence of previous DVT. However, this occurred in only 13 (13%) patients. The PPG determination of venous refilling time did not improve the results obtained with the other tests.Conclusions. The combination of a standardized clinical evaluation with the results of CUS and DUS can reliably diagnose or exclude previous proximal-vein thrombosis in almost 90% of patients with previous episodes of suspected DVT.


2020 ◽  
pp. 54-59
Author(s):  
A. S. Molostova ◽  
N. S. Gladyshev ◽  
A. V. Svarval ◽  
R. S. Ferman ◽  
A. B. Karasyova ◽  
...  

(HP) infection was performed using invasive and non-invasive methods. The study group consisted of 95 patients with dyspepsia. HP infection was detected in 47 patients (49.4 %). The expediency of using a set of diagnostic methods for detecting HP (PCR, immunochromatographic, bacteriological and method for determining urease activity) is proved. Most often (100 %) in patients HP infection was detected in biopsies using the PCR method. Somewhat less frequently it was detected when examining biopsies with an invasive biochemical method (AMA RUT Reader) (82 %) and fecal immunochromatographic method (83 %). Despite the fact that helicobacteriosis was detected bacteriologically in a small number of patients (24 %), this method is of particular value, since it allows you to assess the sensitivity to antimicrobial drugs and probiotics, and does not give false positive results.


2015 ◽  
Vol 24 (2) ◽  
pp. 197-201 ◽  
Author(s):  
Ramesh P. Arasaradnam ◽  
Michael McFarlane ◽  
Emma Daulton ◽  
Erik Westenbrink ◽  
Nicola O’Connell ◽  
...  

Background & Aims: Non-Alcoholic Fatty Liver Disease (NAFLD) is the commonest cause of chronic liver disease in the western world. Current diagnostic methods including Fibroscan have limitations, thus there is a need for more robust non-invasive screening methods. The gut microbiome is altered in several gastrointestinal and hepatic disorders resulting in altered, unique gut fermentation patterns, detectable by analysis of volatile organic compounds (VOCs) in urine, breath and faeces. We performed a proof of principle pilot study to determine if progressive fatty liver disease produced an altered urinary VOC pattern; specifically NAFLD and Non-Alcoholic Steatohepatitis (NASH).Methods: 34 patients were recruited: 8 NASH cirrhotics (NASH-C); 7 non-cirrhotic NASH; 4 NAFLD and 15 controls. Urine was collected and stored frozen. For assay, the samples were defrosted and aliquoted into vials, which were heated to 40±0.1°C and the headspace analyzed by FAIMS (Field Asymmetric Ion Mobility Spectroscopy). A previously used data processing pipeline employing a Random Forrest classification algorithm and using a 10 fold cross validation method was applied.Results: Urinary VOC results demonstrated sensitivity of 0.58 (0.33 - 0.88), but specificity of 0.93 (0.68 - 1.00) and an Area Under Curve (AUC) 0.73 (0.55 -0.90) to distinguish between liver disease and controls. However, NASH/NASH-C was separated from the NAFLD/controls with a sensitivity of 0.73 (0.45 - 0.92), specificity of 0.79 (0.54 - 0.94) and AUC of 0.79 (0.64 - 0.95), respectively.Conclusions: This pilot study suggests that urinary VOCs detection may offer the potential for early non-invasive characterisation of liver disease using 'smell prints' to distinguish between NASH and NAFLD.


2016 ◽  
Vol 1 (1) ◽  
pp. 4
Author(s):  
Marymol Koshy ◽  
Bushra Johari ◽  
Mohd Farhan Hamdan ◽  
Mohammad Hanafiah

Hypertrophic cardiomyopathy (HCM) is a global disease affecting people of various ethnic origins and both genders. HCM is a genetic disorder with a wide range of symptoms, including the catastrophic presentation of sudden cardiac death. Proper diagnosis and treatment of this disorder can relieve symptoms and prolong life. Non-invasive imaging is essential in diagnosing HCM. We present a review to deliberate the potential use of cardiac magnetic resonance (CMR) imaging in HCM assessment and also identify the risk factors entailed with risk stratification of HCM based on Magnetic Resonance Imaging (MRI).


2019 ◽  
Vol 19 (2) ◽  
pp. 105-111
Author(s):  
Nadia Shafei ◽  
Mohammad Saeed Hakhamaneshi ◽  
Massoud Houshmand ◽  
Siavash Gerayeshnejad ◽  
Fardin Fathi ◽  
...  

Background: Beta thalassemia is a common disorder with autosomal recessive inheritance. The most prenatal diagnostic methods are the invasive techniques that have the risk of miscarriage. Now the non-invasive methods will be gradually alternative for these invasive techniques. Objective: The aim of this study is to evaluate and compare the diagnostic value of two non-invasive diagnostic methods for fetal thalassemia using cell free fetal DNA (cff-DNA) and nucleated RBC (NRBC) in one sampling community. Methods: 10 ml of blood was taken in two k3EDTA tube from 32 pregnant women (mean of gestational age = 11 weeks), who themselves and their husbands had minor thalassemia. One tube was used to enrich NRBC and other was used for cff-DNA extraction. NRBCs were isolated by MACS method and immunohistochemistry; the genome of stained cells was amplified by multiple displacement amplification (MDA) procedure. These products were used as template in b-globin segments PCR. cff-DNA was extracted by THP method and 300 bp areas were recovered from the agarose gel as fetus DNA. These DNA were used as template in touch down PCR to amplify b-globin gen. The amplified b-globin segments were sequenced and the results compared with CVS resul. Results: The data showed that sensitivity and specificity of thalassemia diagnosis by NRBC were 100% and 92% respectively and sensitivity and specificity of thalassemia diagnosis by cff-DNA were 100% and 84% respectively. Conclusion: These methods with high sensitivity can be used as screening test but due to their lower specificity than CVS, they cannot be used as diagnostic test.


2005 ◽  
Vol 2 (2) ◽  
pp. 133-140 ◽  
Author(s):  
D. Mietchen ◽  
H. Keupp ◽  
B. Manz ◽  
F. Volke

Abstract. For more than a decade, Magnetic Resonance Imaging (MRI) has been routinely employed in clinical diagnostics because it allows non-invasive studies of anatomical structures and physiological processes in vivo and to differentiate between healthy and pathological states, particularly of soft tissue. Here, we demonstrate that MRI can likewise be applied to fossilized biological samples and help in elucidating paleopathological and paleoecological questions: Five anomalous guards of Jurassic and Cretaceous belemnites are presented along with putative paleopathological diagnoses directly derived from 3D MR images with microscopic resolution. Syn vivo deformities of both the mineralized internal rostrum and the surrounding former soft tissue can be traced back in part to traumatic events of predator-prey-interactions, and partly to parasitism. Besides, evidence is presented that the frequently observed anomalous apical collar might be indicative of an inflammatory disease. These findings highlight the potential of Magnetic Resonance techniques for further paleontological applications.


Author(s):  
Jian Liu ◽  
Yong Yu ◽  
Chenqi Zhu ◽  
Yu Zhang

The finite volume method (FVM)-based computational fluid dynamics (CFD) technology has been applied in the non-invasive diagnosis of coronary artery stenosis. Nonetheless, FVM is a time-consuming process. In addition to FVM, the lattice Boltzmann method (LBM) is used in fluid flow simulation. Unlike FVM solving the Navier–Stokes equations, LBM directly solves the simplified Boltzmann equation, thus saving computational time. In this study, 12 patients with left anterior descending (LAD) stenosis, diagnosed by CTA, are analysed using FVM and LBM. The velocities, pressures, and wall shear stress (WSS) predicted using FVM and LBM for each patient is compared. In particular, the ratio of the average and maximum speed at the stenotic part characterising the degree of stenosis is compared. Finally, the golden standard of LAD stenosis, invasive fractional flow reserve (FFR), is applied to justify the simulation results. Our results show that LBM and FVM are consistent in blood flow simulation. In the region with a high degree of stenosis, the local flow patterns in those two solvers are slightly different, resulting in minor differences in local WSS estimation and blood speed ratio estimation. Notably, these differences do not result in an inconsistent estimation. Comparison with invasive FFR shows that, in most cases, the non-invasive diagnosis is consistent with FFR measurements. However, in some cases, the non-invasive diagnosis either underestimates or overestimates the degree of stenosis. This deviation is caused by the difference between physiological and simulation conditions that remains the biggest challenge faced by all CFD-based non-invasive diagnostic methods.


Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1922
Author(s):  
Gwang Su Kim ◽  
Yumin Park ◽  
Joonchul Shin ◽  
Young Geun Song ◽  
Chong-Yun Kang

The breath gas analysis through gas phase chemical analysis draws attention in terms of non-invasive and real time monitoring. The array-type sensors are one of the diagnostic methods with high sensitivity and selectivity towards the target gases. Herein, we presented a 2 × 4 sensor array with a micro-heater and ceramic chip. The device is designed in a small size for portability, including the internal eight-channel sensor array. In2O3 NRs and WO3 NRs manufactured through the E-beam evaporator’s glancing angle method were used as sensing materials. Pt, Pd, and Au metal catalysts were decorated for each channel to enhance functionality. The sensor array was measured for the exhaled gas biomarkers CH3COCH3, NO2, and H2S to confirm the respiratory diagnostic performance. Through this operation, the theoretical detection limit was calculated as 1.48 ppb for CH3COCH3, 1.9 ppt for NO2, and 2.47 ppb for H2S. This excellent detection performance indicates that our sensor array detected the CH3COCH3, NO2, and H2S as biomarkers, applying to the breath gas analysis. Our results showed the high potential of the gas sensor array as a non-invasive diagnostic tool that enables real-time monitoring.


Sign in / Sign up

Export Citation Format

Share Document