Spectral radiance characteristic measure method based on passive imaging FTIR spectrometer

2016 ◽  
Author(s):  
Song Yue ◽  
Guowei Jia ◽  
Juan Liang ◽  
Zhijie Zhang ◽  
Huawang Chen ◽  
...  
2020 ◽  
pp. 9-24
Author(s):  
Peter Bodrogi ◽  
Xue Guo ◽  
Tran Quoc Khanh

The brightness perception of a large (41°) uniform visual field was investigated in a visual psychophysical experiment. Subjects assessed the brightness of 20 light source spectra of different chromaticities at two luminance levels, Lv=267.6 cd/m2 and Lv=24.8 cd/m2. The resulting mean subjective brightness scale values were modelled by a combination of the signals of retinal mechanisms: S-cones, rods, intrinsically photosensitive retinal ganglion cells (ipRGCs) and the difference of the L-cone signal and the M-cone signal. A new quantity, “relative spectral blue content”, was also considered for modelling. This quantity was defined as “the spectral radiance of the light stimulus integrated with the range (380–520) nm, relative to luminance”. The “relative spectral blue content” model could describe the subjective brightness perception of the observers with reasonable accuracy.


2020 ◽  
Vol 12 (12) ◽  
pp. 1915
Author(s):  
Joe K. Taylor ◽  
Henry E. Revercomb ◽  
Fred A. Best ◽  
David C. Tobin ◽  
P. Jonathan Gero

The Absolute Radiance Interferometer (ARI) is an infrared spectrometer designed to serve as an on-orbit radiometric reference with the ultra-high accuracy (better than 0.1 K 3‑σ or k = 3 brightness temperature at scene brightness temperature) needed to optimize measurement of the long-term changes of Earth’s atmosphere and surface. If flown in an orbit that frequently crosses sun-synchronous orbits, ARI could be used to inter-calibrate the international fleet of infrared (IR) hyperspectral sounders to similar measurement accuracy, thereby establishing an observing system capable of achieving sampling biases on high-information-content spectral radiance products that are also < 0.1 K 3‑σ. It has been shown that such a climate observing system with <0.1 K 2‑σ overall accuracy would make it possible to realize times to detect subtle trends of temperature and water vapor distributions that closely match those of an ideal system, given the limit set by the natural variability of the atmosphere. This paper presents the ARI sensor's overall design, the new technologies developed to allow on-orbit verification and test of its accuracy, and the laboratory results that demonstrate its capability. In addition, we describe the techniques and uncertainty estimates for transferring ARI accuracy to operational sounders, providing economical global coverage. Societal challenges posed by climate change suggest that a Pathfinder ARI should be deployed as soon as possible.


Nanomaterials ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1692
Author(s):  
Emmanuel K. Ampadu ◽  
Jungdong Kim ◽  
Eunsoon Oh

We fabricated a lateral photovoltaic device for use as infrared to terahertz (THz) detectors by chemically depositing PbS films on titanium substrates. We discussed the material properties of PbS films grown on glass with varying deposition conditions. PbS was deposited on Ti substrates and by taking advantage of the Ti/PbS Schottky junction, we discussed the photocurrent transients as well as the room temperature spectrum response measured by Fourier transform infrared (FTIR) spectrometer. Our photovoltaic PbS device operates at room temperature for wavelength ranges up to 50 µm, which is in the terahertz region, making the device highly applicable in many fields.


2021 ◽  
Vol 73 (1) ◽  
Author(s):  
Takayuki Kaneko ◽  
Atsushi Yasuda ◽  
Toshitsugu Fujii

AbstractThe effusion rate of lava is one of the most important eruption parameters, as it is closely related to the migration process of magma underground and on the surface, such as changes in lava flow direction or formation of new effusing vents. Establishment of a continuous and rapid estimation method has been an issue in volcano research as well as disaster prevention planning. For effusive eruptions of low-viscosity lava, we examined the relationship between the nighttime spectral radiance in the 1.6-µm band of the Himawari-8 satellite (R1.6Mx: the pixel value showing the maximum radiance in the heat source area) and the effusion rate using data from the 2017 Nishinoshima activity. Our analysis confirmed that there was a high positive correlation between these two parameters. Based on the linear-regression equation obtained here (Y = 0.47X, where Y is an effusion rate of 106 m3 day−1 and X is an R1.6Mx of 106 W m−2 sr−1 m−1), we can estimate the lava-effusion rate from the observation data of Himawari-8 via a simple calculation. Data from the 2015 Raung activity—an effusive eruption of low-viscosity lava—were arranged along the extension of this regression line, which suggests that the relationship is applicable up to a level of ~ 2 × 106 m3 day−1. We applied this method to the December 2019 Nishinoshima activity and obtained an effusion rate of 0.50 × 106 m3 day−1 for the initial stage. We also calculated the effusion rate for the same period based on a topographic method, and verified that the obtained value, 0.48 × 106 m3 day−1, agreed with the estimation using the Himawari-8 data. Further, for Nishinoshima, we simulated the extent of hazard areas from the initial lava flow and compared cases using the effusion rate obtained here and the value corresponding to the average effusion rate for the 2013–2015 eruptions. The former distribution was close to the actual distribution, while the latter was much smaller. By combining this effusion-rate estimation method with real-time observations by Himawari-8 and lava-flow simulation software, we can build a rapid and precise prediction system for volcano hazard areas.


2005 ◽  
Vol 59 (6) ◽  
pp. 724-731 ◽  
Author(s):  
R. N. Phalen ◽  
Shane S. Que Hee

This study developed a method to produce uniform captan surface films on a disposable nitrile glove for quantitation with a portable attenuated total reflection Fourier transform infrared (ATR-FTIR) spectrometer. A permeation test was performed using aqueous captan formulation. Uniform captan surface films were produced using solvent casting with 2-propanol and a 25 mm filter holder connected to a vacuum manifold to control solvent evaporation. The coefficient of variation of the reflectance at 1735 ± 5 cm−1 was minimized by selection of the optimum solvent volume, airflow rate, and evaporation time. At room temperature, the lower to upper quantifiable limits were 0.31–20.7 μg/cm2 ( r = 0.9967; p ≤ 0.05) for the outer glove surface and 0.55–17.5 μg/cm2 ( r = 0.9409; p ≤ 0.05) for the inner surface. Relative humidity and temperature did not affect the uncoated gloves at the wavelength of captan analysis. Glove screening using ATR-FTIR was necessary as a control for between-glove variation. Captan permeation, after 8 hours exposure to an aqueous concentration of 217 mg/mL of Captan 50-WP, was detected at 0.8 ± 0.3 μg/cm2 on the inner glove surface. ATR-FTIR can detect captan permeation and can determine the protectiveness of this glove in the field.