Development of an auditory fitness-for-duty standard that predicts performance in military hearing tasks from auditory thresholds and performance on the 80-word modified rhyme test

2021 ◽  
Vol 150 (4) ◽  
pp. A339-A339
Author(s):  
Douglas S. Brungart ◽  
Benjamin Sheffield ◽  
Matthew J. Makashay ◽  
Hector Galloza
2021 ◽  
Vol 92 (4) ◽  
pp. 274-280
Author(s):  
Kara M. Cave ◽  
Amanda M. Kelley ◽  
Kathryn A. Feltman ◽  
Jason A. Gerstner ◽  
Justin L. Stewart ◽  
...  

INTRODUCTION: In response to the urgent need for safe aircrew respiratory protection due to the COVID-19 pandemic, three small descriptive evaluations were conducted with aircrew and air traffic controllers (ATC) that assessed the impact of mask use on safety and performance onboard rotary wing aircraft.METHODS: A series of evaluations assessed aircrew performance using the 3MTM Model 1860 N95 respiratory protection mask, two aviation-specific cloth mask prototypes, and a commercial off-the-shelf aviation-specific cloth mask. The series of evaluations included different sets of subjects consisting of up to five Black Hawk helicopter aircrew members, air traffic control (ATC), and 12 CH-47 aircrew members. The Modified Rhyme Test was used to measure speech intelligibility and was administered in the UH-60 among crewmembers of the same aircraft, between pilots of different aircraft, and between the pilots and ATC. Measures of workload, usability, comfort, and pulse oximetry were also administered.RESULTS: Results from the Modified Rhyme Test indicated that all subjects scored greater than 80% accuracy given the proper microphone positioning relative to the mask. With respect to workload, NASA-TLX total scores for the perform radio communications task was 50.83.DISCUSSION: Despite an elevated perceived degree of workload on the communications flight task, results from the speech intelligibility test indicated that performance was maintained within the acceptable range as defined by MIL-STD-1474E, Design Criteria Standard Noise Limit. This abbreviated evaluation suggests that the face masks tested are safe for use by helicopter aircrew under the conditions tested.Cave KM, Kelley AM, Feltman KA, Gerstner JA, Stewart JL, Crowley JS. Aircrew performance and safety while using protective masks in response to coronavirus disease. Aerosp Med Hum Perform. 2021; 92(4):274280.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


1986 ◽  
Vol 50 (5) ◽  
pp. 264-267 ◽  
Author(s):  
GH Westerman ◽  
TG Grandy ◽  
JV Lupo ◽  
RE Mitchell

2008 ◽  
Vol 17 (3) ◽  
pp. 87-92
Author(s):  
Leonard L. LaPointe

Abstract Loss of implicit linguistic competence assumes a loss of linguistic rules, necessary linguistic computations, or representations. In aphasia, the inherent neurological damage is frequently assumed by some to be a loss of implicit linguistic competence that has damaged or wiped out neural centers or pathways that are necessary for maintenance of the language rules and representations needed to communicate. Not everyone agrees with this view of language use in aphasia. The measurement of implicit language competence, although apparently necessary and satisfying for theoretic linguistics, is complexly interwoven with performance factors. Transience, stimulability, and variability in aphasia language use provide evidence for an access deficit model that supports performance loss. Advances in understanding linguistic competence and performance may be informed by careful study of bilingual language acquisition and loss, the language of savants, the language of feral children, and advances in neuroimaging. Social models of aphasia treatment, coupled with an access deficit view of aphasia, can salve our restless minds and allow pursuit of maximum interactive communication goals even without a comfortable explanation of implicit linguistic competence in aphasia.


1964 ◽  
Vol 7 (4) ◽  
pp. 389-393 ◽  
Author(s):  
David C. Shepherd ◽  
Robert Goldstein ◽  
Benjamin Rosenblüt

Two separate studies investigated race and sex differences in normal auditory sensitivity. Study I measured thresholds at 500, 1000, and 2000 cps of 23 white men, 26 white women, 21 negro men, and 24 negro women using the method of limits. In Study II thresholds of 10 white men, 10 white women, 10 negro men, and 10 negro women were measured at 1000 cps using four different stimulus conditions and the method of adjustment by means of Bekesy audiometry. Results indicated that the white men and women in Study I heard significantly better than their negro counterparts at 1000 and 2000 cps. There were no significant differences between the average thresholds measured at 1000 cps of the white and negro men in Study II. White women produced better auditory thresholds with three stimulus conditions and significantly more sensitive thresholds with the slow pulsed stimulus than did the negro women in Study II.


Sign in / Sign up

Export Citation Format

Share Document