Exercises in Motor Development Positions. What Happens With the Activity of Antagonist Muscle Pairs? Pilot Study

2019 ◽  
Vol 28 (1) ◽  
Author(s):  
Esther Casas ◽  
Arturo Justes ◽  
Carlos Calvo

Context: Exercises in motor development positions are employed to activate correct muscular patterns, but the effects on the activity of antagonist muscle pairs remain unknown. Objectives: To determine the effect of using exercises in motor development positions on the activity of antagonist muscle pairs. Another aim was to analyze if introducing some facilitators modifies the muscle activity in the different studied positions. Design: Controlled laboratory study using a single-group repeated measures design. Participants: A total of 21 right handed, healthy adults aged 41 years and older (10 males and 11 females). Setting: Workers of different departments at Maz Hospital. Intervention: Surface electromyography activity of muscle antagonist pairs upper trapezius/lower trapezius, serratus anterior/pectoralis major, and external abdominal oblique/lumbar paraspinal was measured in 3 positions: rest (supine decubitus), reflex turning 1, and modified Vöjta’s first position. Main Outcome Measures: Primary outcomes were mean normalized root mean square (averaged over 2 repetitions) of electromyography signals of antagonist muscle pairs in the 3 analyzed positions. Intraclass correlation coefficients (>.70) (model 3.2), type consistency, and 95% confidence interval were used to estimate the reliability and as exclusion criteria of measurements. Results: Analyzed positions had a significant effect on the activity of the muscles P < .001. There was a significant increase in the activity of the phasic musculature versus its tonic antagonists, except in the case of the external oblique/lumbar paraspinal in modified Vöjta’s first position. Adding possible facilitators such as gaze, breathing, or the combination of both did not show significant changes in the level of activation of the studied muscle groups. Conclusion: Ontogenetic developmental positions can be used to facilitate and improve the activation of phasic muscles.

2012 ◽  
Vol 21 (1) ◽  
Author(s):  
Derya Celik ◽  
Ahmet Dirican ◽  
Gul Baltaci

Context: Handheld dynamometry (HHD) is considered an objective method of measuring strength, but the reliability of the procedure can be compromised by inadequate tester strength and insufficient stabilization of the dynamometer especially, for the scapular muscles. Objective: Primarily, to determine the intrarater reliability of HHD when testing shoulder and scapular muscle strength, and secondarily, to report reliability when corrected for body-mass index (BMI). Design: Technical report. Setting: University physiotherapy department. Participants: 57 adults (17 men, 40 women; mean age = 35.05 ± 13.5 y), both healthy individuals and patients with shoulder impingement. Intervention: HHD. Main Outcome Variables: Muscle strength of the upper, middle, and lower trapezius; anterior deltoid; serratus anterior; supraspinatus; and latissimus dorsi determined by HHD. Each muscle was assessed 3 times, and the mean value was calculated. The subjects were divided into 3 groups according to BMI. Group 1: BMI ≤ 20 kg/m2 (n = 22); Group 2: BMI ≤ 24.9 kg/m2 (n = 54); and Group 3: BMI ≤ 29.9 kg/m2 (n = 38). Results: Correlations were calculated for each pair of strength scores. Intraclass correlation coefficients (ICCs) ranged from .77 to .99 in healthy subjects and from .75 to .99 in patients, for all muscle groups except the upper trapezius (P < .05). Reliability values ranged from good to high in healthy subjects but were less consistent for the upper trapezius (ICC .45-.65). The relationship with BMI and muscle strength illustrates that as BMI increases, there is a decrease in reliability values of the lower trapezius (ICC = .35-.65). Conclusion: The study demonstrates that evaluating the strength of scapular and shoulder muscles using HHD presents reliable results for both patients with impingement syndrome and healthy subjects. Reliability values were compressed when testing the trapezius in subjects with higher BMI. This is likely a result of the examiner's difficulty in overcoming the patients with this maneuver.


2002 ◽  
Vol 82 (4) ◽  
pp. 364-371 ◽  
Author(s):  
Douglas P Gross ◽  
Michele C Battié

Abstract Background and Purpose. Functional capacity evaluations (FCEs) are measurement tools used in predicting readiness to return to work following injury. The interrater and test-retest reliability of determinations of maximal safe lifting during kinesiophysical FCEs were examined in a sample of people who were off work and receiving workers' compensation. Subjects. Twenty-eight subjects with low back pain who had plateaued with treatment were enrolled. Five occupational therapists, trained and experienced in kinesiophysical methods, conducted testing. Methods. A repeated-measures design was used, with raters testing subjects simultaneously, yet independently. Subjects were rated on 2 occasions, separated by 2 to 4 days. Analyses included intraclass correlation coefficients (ICCs) and 95% confidence intervals. Results. The ICC values for interrater reliability ranged from .95 to .98. Test-retest values ranged from .78 to .94. Discussion and Conclusion. Inconsistencies in subjects' performance across sessions were the greatest source of FCE measurement variability. Overall, however, test-retest reliability was good and interrater reliability was excellent.


2020 ◽  
Vol 29 (2) ◽  
pp. 225-230
Author(s):  
Rodrigo Cappato de Araújo ◽  
Vinícius Yan Santos Nascimento ◽  
Rafaela Joyce Barbosa Torres ◽  
Francis Trombini-Souza ◽  
David Behm ◽  
...  

Context: It is believed that conscious abdominal contraction (CAC) during exercise encourages greater periscapular activation through existing myofascial connections. On the other hand, it is postulated that the use of unstable surfaces would promote greater neuromuscular demand. Objective: To analyze the effect of CAC on periscapular muscle activity during push-up plus exercise on stable and unstable surfaces and to evaluate the correlation between electromyographic (EMG) activity of the serratus anterior (SA) and abdominal oblique muscles. Design: Repeated-measures design in a single group, pre–post CAC. Setting: Biomechanics laboratory. Participants: Twenty-three male volunteers without a history of lesions in the upper limbs participated in the study. Main Outcome Measures: Five repetitions of push-ups on stable and unstable surfaces were performed with and without instruction for CAC. The normalized amplitude of the EMG activity was obtained from the muscles of the upper, middle, and lower trapezius, SA upper (SA_5th) and lower (SA_7th) portions, external oblique (EO), and internal oblique. Results: CAC increased the activity of the EO, internal oblique, middle trapezius, and SA (P < .05) in both surfaces. The use of the unstable surface increased the EMG activity of the EO, SA_7th, and middle trapezius and decreased the EMG activity of the SA_5th. However, all changes observed in EMG signals were of low magnitude, with effect sizes lower than 0.45. There was a weak correlation between the EMG activity of the EO and SA_5th (r = .24) and a strong correlation between the EO and SA_7th (r = .70). Conclusion: The isolated use of CAC or unstable surface during push-up seems to present no practical relevance, but the combined use of these strategies may increase activation of the SA_7th and middle trapezius muscles.


2007 ◽  
Vol 16 (1) ◽  
pp. 50-67 ◽  
Author(s):  
Jennifer L. Lister ◽  
Gianluca Del Rossi ◽  
Fangchao Ma ◽  
Mark Stoutenberg ◽  
Jessica B. Adams ◽  
...  

Context:There are numerous ways to overload the scapular stabilizers.Objectives:To assess scapular stabilizer activity using the Bodyblade® and other traditional training devices.Design:Repeated measures analysis of surface EMG data collected from the upper trapezius (UT), lower trapezius (LT), and serratus anterior (SA) during shoulder flexion and abduction using Bodyblade®, cuff weight, and Thera-Band® resistance.Setting:Laboratory.Participants:Thirty collegiate athletes (20.0 ± 1.7 years).Intervention:Participants performed 10 repetitions of shoulder flexion and abduction.Main Outcome Measures:For each movement, normalized root mean square values (NrmsEMG) were computed for each muscle during each repetition under each training condition. Data were analyzed using 3 (condition) × 10 (repetition) repeated measures ANOVAs.Results:During shoulder flexion and abduction, the NrmsEMG of the UT, LT, and SA were significantly greater when using the Bodyblade® than the Thera-Band® or cuff weight.Conclusion:The Bodyblade® produces greater scapular activity than traditional resistance techniques.


Author(s):  
Jodie E. Chapman ◽  
Betina Gardner ◽  
Jennie Ponsford ◽  
Dominique A. Cadilhac ◽  
Renerus J. Stolwyk

Abstract Objective: Neuropsychological assessment via videoconference could assist in bridging service access gaps due to geographical, mobility, or infection control barriers. We aimed to compare performances on neuropsychological measures across in-person and videoconference-based administrations in community-based survivors of stroke. Method: Participants were recruited through a stroke-specific database and community advertising. Stroke survivors were eligible if they had no upcoming neuropsychological assessment, concurrent neurological and/or major psychiatric diagnoses, and/or sensory, motor, or language impairment that would preclude standardised assessment. Thirteen neuropsychological measures were administered in-person and via videoconference in a randomised crossover design (2-week interval). Videoconference calls were established between two laptop computers, facilitated by Zoom. Repeated-measures t tests, intraclass correlation coefficients (ICCs), and Bland–Altman plots were used to compare performance across conditions. Results: Forty-eight participants (26 men; M age = 64.6, SD = 10.1; M time since stroke = 5.2 years, SD = 4.0) completed both sessions on average 15.8 (SD = 9.7) days apart. For most measures, the participants did not perform systematically better in a particular condition, indicating agreement between administration methods. However, on the Hopkins Verbal Learning Test – Revised, participants performed poorer in the videoconference condition (Total Recall Mdifference = −2.11). ICC estimates ranged from .40 to .96 across measures. Conclusions: This study provides preliminary evidence that in-person and videoconference assessment result in comparable scores for most neuropsychological tests evaluated in mildly impaired community-based survivors of stroke. This preliminary evidence supports teleneuropsychological assessment to address service gaps in stroke rehabilitation; however, further research is needed in more diverse stroke samples.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yanzhi Bi ◽  
Xin Hou ◽  
Jiahui Zhong ◽  
Li Hu

AbstractPain perception is a subjective experience and highly variable across time. Brain responses evoked by nociceptive stimuli are highly associated with pain perception and also showed considerable variability. To date, the test–retest reliability of laser-evoked pain perception and its associated brain responses across sessions remain unclear. Here, an experiment with a within-subject repeated-measures design was performed in 22 healthy volunteers. Radiant-heat laser stimuli were delivered on subjects’ left-hand dorsum in two sessions separated by 1–5 days. We observed that laser-evoked pain perception was significantly declined across sessions, coupled with decreased brain responses in the bilateral primary somatosensory cortex (S1), right primary motor cortex, supplementary motor area, and middle cingulate cortex. Intraclass correlation coefficients between the two sessions showed “fair” to “moderate” test–retest reliability for pain perception and brain responses. Additionally, we observed lower resting-state brain activity in the right S1 and lower resting-state functional connectivity between right S1 and dorsolateral prefrontal cortex in the second session than the first session. Altogether, being possibly influenced by changes of baseline mental state, laser-evoked pain perception and brain responses showed considerable across-session variability. This phenomenon should be considered when designing experiments for laboratory studies and evaluating pain abnormalities in clinical practice.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Pieter-Jan Verhelst ◽  
H. Matthews ◽  
L. Verstraete ◽  
F. Van der Cruyssen ◽  
D. Mulier ◽  
...  

AbstractAutomatic craniomaxillofacial (CMF) three dimensional (3D) dense phenotyping promises quantification of the complete CMF shape compared to the limiting use of sparse landmarks in classical phenotyping. This study assesses the accuracy and reliability of this new approach on the human mandible. Classic and automatic phenotyping techniques were applied on 30 unaltered and 20 operated human mandibles. Seven observers indicated 26 anatomical landmarks on each mandible three times. All mandibles were subjected to three rounds of automatic phenotyping using Meshmonk. The toolbox performed non-rigid surface registration of a template mandibular mesh consisting of 17,415 quasi landmarks on each target mandible and the quasi landmarks corresponding to the 26 anatomical locations of interest were identified. Repeated-measures reliability was assessed using root mean square (RMS) distances of repeated landmark indications to their centroid. Automatic phenotyping showed very low RMS distances confirming excellent repeated-measures reliability. The average Euclidean distance between manual and corresponding automatic landmarks was 1.40 mm for the unaltered and 1.76 mm for the operated sample. Centroid sizes from the automatic and manual shape configurations were highly similar with intraclass correlation coefficients (ICC) of > 0.99. Reproducibility coefficients for centroid size were < 2 mm, accounting for < 1% of the total variability of the centroid size of the mandibles in this sample. ICC’s for the multivariate set of 325 interlandmark distances were all > 0.90 indicating again high similarity between shapes quantified by classic or automatic phenotyping. Combined, these findings established high accuracy and repeated-measures reliability of the automatic approach. 3D dense CMF phenotyping of the human mandible using the Meshmonk toolbox introduces a novel improvement in quantifying CMF shape.


Author(s):  
Richard R. Suminski ◽  
Gregory M. Dominick ◽  
Matthew Saponaro

Evidence suggests that video captured with a wearable video device (WVD) may augment or supplant traditional methods for assessing park use. Unmanned aerial systems (UASs) are used to assess human activity, but research employing them for park assessments is sparse. Therefore, this study compared park user counts between a WVD and UAS. A diverse set of 33 amenities (e.g., playground) in three parks were videoed simultaneously by one researcher wearing a WVD and another operating the UAS. Assessments were done at 12 p.m. and 7 p.m. on weekends, with one park evaluated on two occasions 7 days apart. Two investigators independently reviewed videos and reached consensus on the counts of individuals at each amenity. Intraclass correlation coefficients (ICCs) were used to determine intra- and interrater reliabilities. A total of 404 (M = 4.7; SD = 9.6) and 389 (M = 4.5; SD = 9.0) individuals were counted in the UAS and WVD videos, respectively. Absolute agreement was 86% (74/86) and 100% when no individuals were using the amenity. Whether using all 86 videos or only videos having people (48 videos), ICCs indicated excellent reliability (ICC = .99; p < .001). The totals seen for the repeated measures were UAS = 146 and WVD = 136 for Day 1 and UAS = 169 and WVD = 161 for Day 2. Intrarater reliability was excellent for the UAS (ICC = .92; p < .001) and good for the WVD (ICC = .89; p < .001). Disagreement was mainly due to obstructions—people behind or under structures. This study provides support for the use of UASs for counting park users and future research examining the potential benefits of video analysis for assessing park use.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Hannah M. L. Young ◽  
Mark W. Orme ◽  
Yan Song ◽  
Maurice Dungey ◽  
James O. Burton ◽  
...  

Abstract Background Physical activity (PA) is exceptionally low amongst the haemodialysis (HD) population, and physical inactivity is a powerful predictor of mortality, making it a prime focus for intervention. Objective measurement of PA using accelerometers is increasing, but standard reporting guidelines essential to effectively evaluate, compare and synthesise the effects of PA interventions are lacking. This study aims to (i) determine the measurement and processing guidance required to ensure representative PA data amongst a diverse HD population, and; (ii) to assess adherence to PA monitor wear amongst HD patients. Methods Clinically stable HD patients from the UK and China wore a SenseWear Armband accelerometer for 7 days. Step count between days (HD, Weekday, Weekend) were compared using repeated measures ANCOVA. Intraclass correlation coefficients (ICCs) determined reliability (≥0.80 acceptable). Spearman-Brown prophecy formula, in conjunction with a priori ≥  80% sample size retention, identified the minimum number of days required for representative PA data. Results Seventy-seven patients (64% men, mean ± SD age 56 ± 14 years, median (interquartile range) time on HD 40 (19–72) months, 40% Chinese, 60% British) participated. Participants took fewer steps on HD days compared with non-HD weekdays and weekend days (3402 [95% CI 2665–4140], 4914 [95% CI 3940–5887], 4633 [95% CI 3558–5707] steps/day, respectively, p < 0.001). PA on HD days were less variable than non-HD days, (ICC 0.723–0.839 versus 0.559–0.611) with ≥ 1 HD day and ≥  3 non-HD days required to provide representative data. Using these criteria, the most stringent wear-time retaining ≥ 80% of the sample was ≥7 h. Conclusions At group level, a wear-time of ≥7 h on ≥1HD day and ≥ 3 non-HD days is required to provide reliable PA data whilst retaining an acceptable sample size. PA is low across both HD and non- HD days and future research should focus on interventions designed to increase physical activity in both the intra and interdialytic period.


2012 ◽  
Vol 102 (2) ◽  
pp. 130-138 ◽  
Author(s):  
Jeanna M. Fascione ◽  
Ryan T. Crews ◽  
James S. Wrobel

Background: Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. Methods: On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Results: Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85–0.96) and electronic pedography (ICC, 0.29–0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74–0.99). Conclusions: Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high. (J Am Podiatr Med Assoc 102(2): 130–138, 2012)


Sign in / Sign up

Export Citation Format

Share Document