scholarly journals Protocol on a multicentre statistical and economic modelling study of risk-based stratified and personalised screening for diabetes and its complications in India (SMART India)

BMJ Open ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. e039657
Author(s):  
Sobha Sivaprasad ◽  
Rajiv Raman ◽  
Ramachandran Rajalakshmi ◽  
Viswanathan Mohan ◽  
Mohan Deepa ◽  
...  

IntroductionThe aim of this study is to develop practical and affordable models to (a) diagnose people with diabetes and prediabetes and (b) identify those at risk of diabetes complications so that these models can be applied to the population in low-income and middle-income countries (LMIC) where laboratory tests are unaffordable.Methods and analysisThis statistical and economic modelling study will be done on at least 48 000 prospectively recruited participants aged 40 years or above through community screening across 20 predefined regions in India. Each participant will be tested for capillary random blood glucose (RBG) and complete a detailed health-related questionnaire. People with known diabetes and all participants with predefined levels of RBG will undergo further tests, including point-of-care (POC) glycated haemoglobin (HbA1c), POC lipid profile and POC urine test for microalbuminuria, retinal photography using non-mydriatic hand-held retinal camera, visual acuity assessment in both eyes and complete quality of life questionnaires. The primary aim of the study is to develop a model and assess its diagnostic performance to predict HbA1c diagnosed diabetes from simple tests that can be applied in resource-limited settings; secondary outcomes include RBG cut-off for definition of prediabetes, diagnostic accuracy of cost-effective risk stratification models for diabetic retinopathy and models for identifying those at risk of complications of diabetes. Diagnostic accuracy inter-tests agreement, statistical and economic modelling will be performed, accounting for clustering effects.Ethics and disseminationThe Indian Council of Medical Research/Health Ministry Screening Committee (HMSC/2018–0494 dated 17 December 2018 and institutional ethics committees of all the participating institutions approved the study. Results will be published in peer-reviewed journals and will be presented at national and international conferences.Trial registration numberISRCTN57962668 V1.0 24/09/2018.

Diagnostics ◽  
2021 ◽  
Vol 11 (8) ◽  
pp. 1352
Author(s):  
Darius Riziki Martin ◽  
Nicole Remaliah Sibuyi ◽  
Phumuzile Dube ◽  
Adewale Oluwaseun Fadaka ◽  
Ruben Cloete ◽  
...  

The transmission of Tuberculosis (TB) is very rapid and the burden it places on health care systems is felt globally. The effective management and prevention of this disease requires that it is detected early. Current TB diagnostic approaches, such as the culture, sputum smear, skin tuberculin, and molecular tests are time-consuming, and some are unaffordable for low-income countries. Rapid tests for disease biomarker detection are mostly based on immunological assays that use antibodies which are costly to produce, have low sensitivity and stability. Aptamers can replace antibodies in these diagnostic tests for the development of new rapid tests that are more cost effective; more stable at high temperatures and therefore have a better shelf life; do not have batch-to-batch variations, and thus more consistently bind to a specific target with similar or higher specificity and selectivity and are therefore more reliable. Advancements in TB research, in particular the application of proteomics to identify TB specific biomarkers, led to the identification of a number of biomarker proteins, that can be used to develop aptamer-based diagnostic assays able to screen individuals at the point-of-care (POC) more efficiently in resource-limited settings.


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Andrew W. Kirkpatrick ◽  
Jessica L. McKee ◽  
John M. Conly

AbstractCOVID-19 has impacted human life globally and threatens to overwhelm health-care resources. Infection rates are rapidly rising almost everywhere, and new approaches are required to both prevent transmission, but to also monitor and rescue infected and at-risk patients from severe complications. Point-of-care lung ultrasound has received intense attention as a cost-effective technology that can aid early diagnosis, triage, and longitudinal follow-up of lung health. Detecting pleural abnormalities in previously healthy lungs reveal the beginning of lung inflammation eventually requiring mechanical ventilation with sensitivities superior to chest radiographs or oxygen saturation monitoring. Using a paradigm first developed for space-medicine known as Remotely Telementored Self-Performed Ultrasound (RTSPUS), motivated patients with portable smartphone support ultrasound probes can be guided completely remotely by a remote lung imaging expert to longitudinally follow the health of their own lungs. Ultrasound probes can be couriered or even delivered by drone and can be easily sterilized or dedicated to one or a commonly exposed cohort of individuals. Using medical outreach supported by remote vital signs monitoring and lung ultrasound health surveillance would allow clinicians to follow and virtually lay hands upon many at-risk paucisymptomatic patients. Our initial experiences with such patients are presented, and we believe present a paradigm for an evolution in rich home-monitoring of the many patients expected to become infected and who threaten to overwhelm resources if they must all be assessed in person by at-risk care providers.


2018 ◽  
Vol 146 (6) ◽  
pp. 747-756
Author(s):  
J.M. Hughes ◽  
C. Penney ◽  
S. Boyd ◽  
P. Daley

AbstractCommercial point-of-care (POC) diagnostic tests for Group A Streptococcus, Streptococcus pneumoniae, and influenza virus have large potential diagnostic and financial impact. Many published reports on test performance, often funded by diagnostics companies, are prone to bias. The Standards for Reporting of Diagnostic Accuracy (STARD 2015) are a protocol to encourage accurate, transparent reporting. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool evaluates risk of bias and transportability of results. We used these tools to evaluate diagnostic test accuracy studies of POC studies for three respiratory pathogens. For the 96 studies analysed, compliance was <25% for 14/34 STARD 2015 standards, and 3/7 QUADAS-2 domains showed a high risk of bias. All reports lacked reporting of at least one criterion. These biases should be considered in the interpretation of study results.


2019 ◽  
Vol 6 (6) ◽  
pp. e382-e395 ◽  
Author(s):  
Annie Haakenstad ◽  
Mark W Moses ◽  
Tianchan Tao ◽  
Golsum Tsakalos ◽  
Bianca Zlavog ◽  
...  

Blood ◽  
2019 ◽  
Vol 134 (Supplement_1) ◽  
pp. 3373-3373
Author(s):  
Arwa Fraiwan ◽  
Muhammad Noman Hasan ◽  
Ran An ◽  
Julia Z. Xu ◽  
Amy J. Rezac ◽  
...  

Introduction: Nearly 24% of the world's population carry hemoglobin (Hb) gene variants, with the large majority of affected births occurring in low-income countries. The most prevalent structural Hb variants are the recessive β-globin gene mutations, βS or S, βC or C, and βE or E1. Hb S mutation is prevalent in sub-Saharan Africa and in Central India. Hb C is common in West Africa, and Hb E is common in Southeast Asia and in India. Homozygotes or compound heterozygotes with βS (e.g., Hb SS or SC) have sickle cell disease (SCD), a chronic sickling disorder associated with pain, chronic multi-organ damage, and high mortality. While Hb EE causes only a mild microcytic anemia, Hb E in combination with β-thalassemia can lead to transfusion dependent thalassemia. Though carriers are typically asymptomatic, they may pass the mutations to their offspring. Screening is needed so that these disorders can be diagnosed early and managed in a timely manner2. For example, in low-income countries, due to lack of nationwide screening and comprehensive care programs, up to 80% of babies born with SCD are undiagnosed and less than half of them survive beyond 5 years of age2. The unmet need for affordable, portable, accurate point-of-care tests to facilitate decentralized hemoglobin testing in resource-constrained countries is well-recognized 2,3. Here, we present international multi-site clinical validation results and high diagnostic accuracy of the 'HemeChip' (Fig. 1), an affordable, 10-minute point-of-care microchip electrophoresis test for identifying common Hb variants S, C, and E. Methods: Institutional Review Board approvals were obtained at each study site, and blood samples were collected as part of the standard clinical care. Tests were performed by local users, including healthcare workers and clinical laboratory personnel. 315 children (6 weeks to 5 years of age) were tested in Kano, Nigeria. Study participants were enrolled at three hospitals, Amino Kano Teaching Hospital, Murtala Mohammed Specialist Hospital, and Hasiya Bayero Pediatric Hospital. 124 subjects (7 weeks to 63 years old) were included in the study at Siriraj Thalassemia Center in Bangkok, Thailand. 298 subjects (8 months to 65 years old) were tested at a referral testing facility of ICMR-National Institute of Research in Tribal Health, located at Late Baliram Kashayap Memorial Medical College, Jagdalpur, Chhattisgarh, India. Blood samples were tested with both HemeChip and the standard reference methods, high performance liquid chromatography or cellulose acetate electrophoresis. Reference test results were not available to the HemeChip users. Similarly, HemeChip test results were not available to the users of the standard reference tests. Clinical validation studies presented here were performed with a fully functional, portable HemeChip prototype developed at Case Western Reserve University (Fig. 1A). A commercial product has been developed based on this technology by Hemex Health Inc. under the product name, GazelleTM(Fig. 1B). Results and Discussion: Among the total 768 tests performed with HemeChip in all test sites, 732 were valid tests, as defined by the Standards for Reporting Diagnostic Accuracy (STARD)4. HemeChip correctly identified all subjects with Hb SS, Hb SC, Hb AS, Hb AE, and Hb EE with 100% accuracy (Table 1). Nine subjects with normal Hb (Hb AA) were identified as HbSS in Nigeria. No subjects with disease were identified as normal or trait by HemeChip. Three subjects with compound heterozygous Hb Sβ-thalassemia (2 subjects with Hb Sβ+-thalassemia, 1 subject with Hb Sβ0-thalassemia) were identified as Hb SS. Sensitivity was 100% for all Hb types tested. Specificity was 98.7% for Hb SS versus other Hb types, and 100% for all other Hb types tested. HemeChip displayed an overall diagnostic accuracy of 98.4% in comparison to standard reference methods for the Hb variants tested in all clinical testing sites (Table 1). HemeChip is a versatile point-of-care system that enables affordable, accurate, decentralized hemoglobin testing in resource-limited settings. References: 1. Weatherall DJ, Clegg JB. Bull World Health Organ. 2001;79(8):704-712. 2. Mburu J, Odame I. International Journal of Laboratory Hematology. 2019;41(S1):82-88. 3. Alapan Y, Fraiwan A, Kucukal E, et al. Expert Review of Medical Devices. 2016;13(12):1073-1093. 4. Bossuyt PM, Reitsma JB, Bruns DE, et al. BMJ : British Medical Journal. 2015;351:h5527. Disclosures Fraiwan: Hemex Health, Inc.: Equity Ownership, Patents & Royalties. Hasan:Hemex Health, Inc.: Equity Ownership, Patents & Royalties. An:Hemex Health, Inc.: Patents & Royalties. Thota:Hemex Health, Inc.: Employment. Piccone:Hemex Health, Inc.: Patents & Royalties. Little:Hemex Health, Inc.: Patents & Royalties; GBT: Research Funding. Gurkan:Hemex Health, Inc.: Consultancy, Employment, Equity Ownership, Patents & Royalties, Research Funding.


Biology ◽  
2020 ◽  
Vol 9 (8) ◽  
pp. 182 ◽  
Author(s):  
Robin Augustine ◽  
Anwarul Hasan ◽  
Suvarthi Das ◽  
Rashid Ahmed ◽  
Yasuyoshi Mori ◽  
...  

The rampant spread of COVID-19 and the worldwide prevalence of infected cases demand a rapid, simple, and cost-effective Point of Care Test (PoCT) for the accurate diagnosis of this pandemic. The most common molecular tests approved by regulatory bodies across the world for COVID-19 diagnosis are based on Polymerase Chain Reaction (PCR). While PCR-based tests are highly sensitive, specific, and remarkably reliable, they have many limitations ranging from the requirement of sophisticated laboratories, need of skilled personnel, use of complex protocol, long wait times for results, and an overall high cost per test. These limitations have inspired researchers to search for alternative diagnostic methods that are fast, economical, and executable in low-resource laboratory settings. The discovery of Loop-mediated isothermal Amplification (LAMP) has provided a reliable substitute platform for the accurate detection of low copy number nucleic acids in the diagnosis of several viral diseases, including epidemics like Severe Acute Respiratory Syndrome (SARS) and Middle East Respiratory Syndrome (MERS). At present, a cocktail of LAMP assay reagents along with reverse transcriptase enzyme (Reverse Transcription LAMP, RT-LAMP) can be a robust solution for the rapid and cost-effective diagnosis for COVID-19, particularly in developing, and low-income countries. In summary, the development of RT-LAMP based diagnostic tools in a paper/strip format or the integration of this method into a microfluidic platform such as a Lab-on-a-chip may revolutionize the concept of PoCT for COVID-19 diagnosis. This review discusses the principle, technology and past research underpinning the success for using this method for diagnosing MERS and SARS, in addition to ongoing research, and the prominent prospect of RT-LAMP in the context of COVID-19 diagnosis.


1999 ◽  
Vol 45 (4) ◽  
pp. 478-485 ◽  
Author(s):  
Bjarne Steen Dahler-Eriksen ◽  
Torsten Lauritzen ◽  
Jens Flensted Lassen ◽  
Erik D Lund ◽  
Ivan Brandslund

Abstract Background: The benefits of near-patient, point-of-care tests have not been fully examined. We have assessed the clinical, organizational, and economic outcomes of implementing a near-patient test for C-reactive protein (CRP) in general practice. Methods: In a randomized crossover trial during intervention periods, general practitioners (GPs) were allowed to measure CRP within 3 min, using NycoCard® CRP. During control periods, they had to mail blood samples for CRP measurements to the hospital laboratory and received test results 24–48 h later. Twenty-nine general practice clinics participated (64 GPs), and 1853 patients were included in the study. Results were evaluated at both the level of participating GPs and the level of included patients. Results: For participating GPs, the overall use of erythrocyte sedimentation rates (ESRs) decreased by 8% (95% confidence interval, 1–14%) during intervention periods, and the number of blood samples mailed to the hospital laboratory decreased by 6% (1–10%). No reduction in the prescription of antibiotics was seen. The proportion of study patients having a follow-up telephone consultation was reduced from 63% to 53% (P = 0.0001), and patients with CRP concentrations &gt;50 mg/L had their antibiotic treatments started earlier when CRP was measured in general practices (P = 0.0161). Conclusion: The implementation of the near-patient CRP test was cost-effective mainly on the basis of a reduction in the use of services from the hospital laboratory by GPs. If the implementation is followed by education and clinical guidelines, opportunities exist for additional reduction in the use of ESR and for a more appropriate use of antibiotics.


2020 ◽  
pp. 1147-1154
Author(s):  
Roopa Hariprasad ◽  
Sonam Tulsyan ◽  
Roshani Babu ◽  
Kavitha Dhanasekaran ◽  
Nisha Thakur ◽  
...  

PURPOSE Currently available human papillomavirus (HPV) detection devices are expensive, requiring a continuous power supply, high-priced reagents, skilled laboratory personnel, and infrastructure. These make it difficult to implement primary HPV screening in high-risk (HR) populations, particularly in low-income settings such as in India. The objective of our study was to evaluate the diagnostic performance of a point-of-care, portable, battery-operated device called Truenat, which detects 4 HR HPV genotypes (16, 18, 31, and 45), as a potentially cost-effective alternative to conventional HPV diagnostic tests. PATIENTS AND METHODS This was a single-site, blinded, cross-sectional study that evaluated the performance of the Trunat HPV-HR using cervical samples collected from nonpregnant women > 30 years old via consecutive sampling. The comparison was conducted against the Hybrid Capture 2 (HC2) method. All the positive samples were validated by 14 Real-TM Quant Kit. RESULTS Of 615 cervical samples, the HR-HPV DNA test was positive in 78 women (12.7%) by HC2 and in 49 (8%) by Truenat. With the consideration of limited genotype inclusivity, the sensitivity and specificity of Truenat HPV-HR were 97.7% and 98.9%, respectively. CONCLUSION The performance of Truenat HPV-HR test was comparable to that of HC2 in the 4 HPV genotypes and would be appropriate to consider for use in primary HR cervical cancer screening and particularly in low-income settings.