381 Role of CT scans of abdomen and pelvis in management of patients with immunotherapy-induced colitis

2020 ◽  
Vol 8 (Suppl 3) ◽  
pp. A406-A406
Author(s):  
Juan Ibarra Rovira ◽  
Raghunandan Vikram ◽  
Selvi Thirumurthi ◽  
Bulent Yilmaz ◽  
Heather Lin ◽  
...  

BackgroundColitis is one of the most common immune-related adverse event in patients who receive immune checkpoint inhibitors targeting cytotoxic T-lymphocyte antigen 4 (CTLA-4) and programmed cell death-1 (PD-1). Although radiographic changes are reported on computed tomography such as mild diffuse bowel thickening or segmental colitis, the utility of CT in diagnosis of patients with suspected immune-related colitis is not well studied.MethodsCT scans of the abdomen and pelvis of 34 patients on immunotherapy with a clinical diagnosis of immunotherapy induced colitis and 19 patients receiving immunotherapy without clinical symptoms of colitis (control) were enrolled in this retrospective study. Segments of the colon (rectum, sigmoid, descending, transverse, ascending and cecum) were assessed independently by two fellowship trained abdominal imaging specialists with 7 and 13 years‘ experience who were blinded to the clinical diagnosis. Each segment was assessed for mucosal enhancement, wall thickening, distension, peri-serosal fat stranding. Any disagreements were resolved in consensus. The degree of distension and the spurious assignment of wall thickening were the most common causes for disagreement. The presence of any of the signs was considered as radiographic evidence of colitis.ResultsCT evidence of colitis was seen in 16 of 34 patients with symptoms of colitis. 7 of 19 patients who did not have symptoms of colitis showed signs of colitis on CT. The sensitivity, specificity, Positive Predictive Value and Negative Predictive Value for colitis on CT is 47%, 63.2%, 69.5% and 40%, respectively.ConclusionsCT has a low sensitivity, specificity and negative predictive value for the diagnosis of immunotherapy-induced colitis. CT has no role in the diagnosis of patients suspected of having uncomplicated immune-related colitis and should not be used routinely for management.Trial RegistrationThis protocol is not registered on clinicaltrials.gov.Ethics ApprovalThis protocol was IRB approved on: 11/16/2015 - IRB 4 Chair Designee FWA #: 00000363 OHRP IRB Registration Number: IRB 4 IRB00005015ConsentThis protocol utilizes an IRB approved waiver of consent.

2014 ◽  
Vol 47 (2) ◽  
pp. 84-88 ◽  
Author(s):  
Brenda Carla Lima Araújo ◽  
Maria Eugênia Almeida Motta ◽  
Adriana Guerra de Castro ◽  
Claudia Marina Tavares de Araújo

Objective To evaluate the contribution of deglutition videofluoroscopy in the clinical diagnosis of dysphagia in chronic encephalopathy of childhood. Materials and Methods The study sample consisted of 93 children diagnosed with chronic encephalopathy, in the age range between two and five years, selected by convenience among patients referred to the authors' institution by speech therapists, neurologists and gastroenterologists in the period from March 2010 to September 2011. The data collection was made at two different moments, by different investigators who were blind to each other. Results The method presented low sensitivity for detecting aspiration with puree consistency (p = 0.04). Specificity and negative predictive value were high for clinical diagnosis of dysphagia with puree consistency. Conclusion In the present study, the value for sensitivity in the clinical diagnosis of dysphagia demonstrates that this diagnostic procedure may not detect any change in the swallowing process regardless of the food consistency used during the investigation. Thus, the addition of the videofluoroscopic method can significantly contribute to the diagnosis of dysphagia.


Author(s):  
Anand Rai Bansal ◽  
Suvendu Sekhar Jena ◽  
Sanjeev Kumar

Objective: Correlation of Ultrasound and RIPASA scoring system in the diagnosis of acute appendicitis. Study Design: 50 patients presenting to emergency underwent ultrasound and evaluation as per RIPASA scoring system followed by emergency appendicectomy. The sensitivity, specificity, positive and negative predictive value calculated for each goups. Results: The sensitivity, specificity, Positive Predictive Value and Negative Predictive Value for ultrasound were 75.51%, 100%, 100% and 7.69% respectively and that for RIPASA scoring system were 93.9%, 100% 100% and 25% respectively. The negative appendicectomy rate was 2%. Conclusion: RIPASA scoring system may be used for correctly diagnosing acute appendicitis but low sensitivity of ultrasound precludes its routine use and may be used as a complementary tool in diagnosing acute appendicitis. Keywards: Acute Appendictis, RIPASA, Ultrasound.


2021 ◽  
Vol 9 (02) ◽  
pp. 315-321
Author(s):  
Abdullah Hamdan ◽  
◽  
Nasraldeen Alnaeem M. Alkhidir ◽  
Abdelmoneim Saeed ◽  
◽  
...  

The diagnosis of acute appendicitis is mainly clinical and to confirm the clinical diagnosis ultrasonography (USG) of the abdomen is being used to help in diagnosis of the disease. To find out the role of USG in the diagnosis of acute appendicitis in clinically equivocal cases and to correlate USG findings with histopathological reports (HPR) of removed appendix.Total numbers of 100 patients were included in the study from 12March 2019 to 5 December 2019. Findings on ultrasound were finally compared with histopathological report of appendices removed on surgery. Those cases with alternate diagnosis were followed up and proved with other means of investigation. The sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of ultrasound in diagnosis of acute appendicitis in our study were found to be 79 %, 84.20 %, 95.50%, 48.40% and 80% respectively.


2018 ◽  
Vol 5 (r) ◽  
Author(s):  
Anand Rai BANSAL ◽  
Suvendu Sekhar JENA ◽  
Sanjeev KUMAR

Objective: Correlation of Ultrasound and RIPASA scoring system in the diagnosis of acute appendicitis. Study Design: 50 patients presenting to emergency underwent ultrasound and evaluation as per RIPASA scoring system followed by emergency appendicectomy. The sensitivity, specificity, positive and negative predictive value calculated for each goups. Results: The sensitivity, specificity, Positive Predictive Value and Negative Predictive Value for ultrasound were 75.51%, 100%, 100% and 7.69% respectively and that for RIPASA scoring system were 93.9%, 100% 100% and 25% respectively. The negative appendicectomy rate was 2%. Conclusion: RIPASA scoring system may be used for correctly diagnosing acute appendicitis but low sensitivity of ultrasound precludes its routine use and may be used as a complementary tool in diagnosing acute appendicitis. Keywards: Acute Appendictis, RIPASA, Ultrasound.


2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Maral Seyed Ahadi ◽  
Alireza Firooz ◽  
Hoda Rahimi ◽  
Mehrdad Jafari ◽  
Zohreh Tehranchinia

Background. The increasing incidence of skin cancers in fair-skinned population and its relatively good response to treatment make its accurate diagnosis of great importance. We evaluated the accuracy of clinical diagnosis of malignant skin lesions by comparing the clinical diagnosis with histological diagnosis as the gold standard. Materials and Methods. In this retrospective study, we assessed all the pathology reports from specimens sent to a university hospital laboratory in 3 consecutive years from March 2008 to March 2010. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and positive and negative likelihood ratios were calculated for clinical diagnosis of malignant skin lesions stratified by their histological subtype. Results. A total 4,123 specimen were evaluated. The sensitivity and specificity for clinical diagnosis of malignancy were 90.48% and 82.85%, respectively, whereas the negative predictive value was shown to be 99.06%. The positive and negative likelihood ratios were 5.23 and 0.11, respectively. Conclusion. Pathological assessment of skin lesions remains the cornerstone of skin cancer diagnosis. The high NPV and the relatively low PPV indicate that clinical diagnosis is more efficient in ruling out malignancies rather than diagnosing them.


KYAMC Journal ◽  
2021 ◽  
Vol 12 (3) ◽  
pp. 142-146
Author(s):  
Raseul Kabir ◽  
Md Amjad Hossain Pramanik ◽  
SM Emdadul Haque ◽  
Muhatarima Tabassum ◽  
Fateha Sultana

Background: The clinical diagnosis of stroke in a patient admitted in the intensive care unit (ICU) is undeniably challenging. Several point-based risk scores have been developed to predict clinical outcomes after ischemic stroke. Objective: To assess the Siriraj stroke score and Guy’s Hospital stroke score in the clinical diagnosis of acute stroke. Materials and Methods: All patients were subjected to Computed tomography (CT) scan head within 72 hours of admission. The sensitivity, specificity, positive predictive value was calculated for both the scores. Comparability between the scores and CT scan head finding was determined with the help of Kappa statistic program. Results: Sensitivity of Guy’s Hospital stroke score for ischemic stroke is 100%, specificity is 96.4%, accuracy 97.1%, positive predictive value of 87.5% and negative predictive value 100%. The sensitivity of Guy’s Hospital stroke score for hemorrhage stroke is 96.4%, specificity is 100%, accuracy 97.1%, positive predictive value of 100% and negative predictive value 87.5% Conclusion: Siriraj stroke score as a simple method of screening patients for intracerebral hemorrhage, as it is easier to use at bedside and has a greater accuracy in diagnosing hemorrhage than Guy’s Hospital score. KYAMC Journal. 2021;12(3): 142-146


2018 ◽  
Vol 1 ◽  
pp. 9
Author(s):  
Harshad Arvind Vanjare ◽  
Jyoti Panwar

Objective The objective of the study was to assess the accuracy of ultrasound examination for the diagnosis of rotator cuff tear and tendinosis performed by a short experienced operator, compared to magnetic resonance imaging (MRI) results. Method A total of 70 subjects suspected to have rotator cuff tear or tendinosis and planned for shoulder MRI were included in the study. Shoulder ultrasound was performed either before or after the MRI scan on the same day. Ultrasound operator had a short experience in performing an ultrasound of the shoulder. Ultrasound findings were correlated to MRI findings. Results Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for the diagnosis of tendinosis were 58%, 84%, 63%, 80%, and 75%, respectively, and it was 68%, 91%, 73%, 88%, and 85%, respectively, for the diagnosis of rotator cuff tear. Conclusions Sensitivity for diagnosing rotator cuff tear or tendinosis was moderate but had a higher negative predictive value. Thus, the ultrasound operator with a short experience in performing shoulder ultrasound had moderate sensitivity in diagnosing tendinosis or tears; however, could exclude them with confidence.


2021 ◽  
Vol 10 (12) ◽  
pp. 2675
Author(s):  
Monika Zajkowska ◽  
Agnieszka Kulczyńska-Przybik ◽  
Maciej Dulewicz ◽  
Kamil Safiejko ◽  
Marcin Juchimiuk ◽  
...  

Colorectal cancer (CRC) is one of the most common malignancies. Despite the availability of diagnostic tests, an increasing number of new cases is observed. That is why it is very important to search new markers that would show high diagnostic utility. Therefore, we made an attempt to assess the usefulness of eotaxins, as there are few studies that investigate their significance, in patients with CRC. The study included 80 subjects (CRC patients and healthy volunteers). Serum concentrations of all eotaxins were measured using a multiplexing method (Luminex), while CCR3 was measured by immunoenzymatic assay (ELISA). CRP levels were determined by immunoturbidimetry and classical tumor marker levels (CEA and CA 19-9) and were measured using chemiluminescent microparticle immunoassay (CMIA). The highest usefulness among the proteins tested showed CCR3. Its concentrations were significantly higher in the CRC group than in healthy controls. The diagnostic sensitivity, specificity, positive and negative predictive value, and the area under the ROC curve (AUC) of CCR3 were higher than those of CA 19-9. The maximum values for sensitivity, negative predictive value, and AUC were obtained for a combination of CCR3 and CRP. Our findings suggest the potential usefulness of CCR3 in the diagnosis of CRC, especially in combination with CRP or CEA.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Author(s):  
Dagmar Lagerberg ◽  
Margaretha Magnusson ◽  
Claes Sundelin

Abstract Background: The Edinburgh Postnatal Depression Scale (EPDS) is widely used in early child health care. This study examined the appropriateness of the recommended EPDS cut-off score 11/12. Methods: Two main analyses were performed: 1. Associations between EPDS scores and maternal health behaviour, stress, life events, perceived mother-child interaction quality and child behaviour. 2. Screening parameters of the EPDS, i.e., sensitivity, specificity and positive predictive value. EPDS scores were available for 438 mothers and maternal questionnaires for 361 mothers. Results: Already in the EPDS score intervals 6–8 and 9–11, there were notable adversities, according to maternal questionnaires, in stress, perceived quality of mother-child interaction, perceived child difficultness and child problem behaviours. Using maternal questionnaire reports about sadness/distress postpartum as standard, the recommended EPDS cut-off score 11/12 resulted in a very low sensitivity (24%). The cut-off score 6/7 yielded a sensitivity of 61%, a specificity of 82% and a positive predictive value of 61%. Conclusions: In terms of both clinical relevance and screening qualities, an EPDS cut-off score lower than 11/12 seems recommendable.


Sign in / Sign up

Export Citation Format

Share Document