scholarly journals P067 Timing of primary syphilis treatment and impact on the development of treponemal antibodies: A cross-sectional clinic-based study

Author(s):  
J Towns ◽  
D Leslie ◽  
I Denham ◽  
F Azzato ◽  
T Karapanagiotidis ◽  
...  
2021 ◽  
pp. sextrans-2020-054739
Author(s):  
Janet M Towns ◽  
David E Leslie ◽  
Ian Denham ◽  
Francesca Azzato ◽  
Theo Karapanagiotidis ◽  
...  

BackgroundSerology is negative in a proportion of primary syphilis cases where Treponema pallidum PCR testing is positive. We aimed to identify discordant, T. pallidum PCR-positive, serology-negative primary syphilis cases and any clinical or laboratory factors associated with failure to subsequently seroconvert.MethodsSerodiscordant primary syphilis cases that were T. pallidum PCR-positive and serology-negative (including rapid plasma reagin, T. pallidum particle agglutination, T. pallidum enzyme immunoassay or T. pallidum chemiluminescence assay) were identified from the Melbourne Sexual Health Centre electronic records between April 2011 and December 2019. Clinical and laboratory associations were examined.ResultsThere were 814 primary syphilis cases in the study period and 38 (4.7%) were serodiscordant, 35 in men who have sex with men. Thirty-two had follow-up serology performed a median of 24 days later, of which 16 (50%) seroconverted, mostly (81%) within 6 weeks. Failure to seroconvert was significantly associated with treatment on day 1. Of the 12 cases treated on day 1, 10 (83%) failed to seroconvert compared with 6 of 20 (30%) among those who were treated after day 1.DiscussionEarlier treatment of primary syphilis can prevent the development of serological markers. T. pallidum PCR can identify primary syphilis lesions before the development of serological markers and improve diagnosis of early primary syphilis lesions. Serology alone will miss a proportion of primary syphilis infections and should be repeated if a diagnosis of syphilis is being considered.


2021 ◽  
Vol 62 (5) ◽  
Author(s):  
Hoang Van Khoan ◽  
Phuong Quynh Hoa

Quality of life is a widely used concept to measure the results of treatment of patients in general and patients with genital warts in particular. To provide data on the quality of life of warts patientstreated at the National Hospital of Dermatology, as a basis for improving the quality of treatment, we conducted this study to: Describe the quality of life. Survival of patients with warts treated at the National Hospital of Dermatology. This is a cross-sectional descriptive study. Information was collected through interviews with 210 patients with warts treated at the National Hospital of Dermatology (December 6, 2020) using the QE-5D-5L quality of life measurement tool kit. Research results show that the quality of life is quite and good accounted for 57.6% with a quality of life score of 0.9910 ± 0.058, an average quality of life is quite good at 36.2% with a quality of life score of 0.729 ± 0.048, mean quality of life is 2.9%with quality of life score of 0.533 ± 0.043, patients with poor quality of life account for 3.3% of quality of life, which is 0.288 ± 0.101.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
Vicente Estrada ◽  
Eva Santiago ◽  
Inmaculada Cabezas ◽  
Juan Luis Cotano ◽  
Juan Carlos Carrió ◽  
...  

Abstract Background Penicillin G Benzathine (PGB) is the cornerstone of syphilis treatment. However, its intramuscular (IM) administration is associated with pain at the site of injection. The dilution of PGB with local anesthetics is recommended in some guidelines, but the evidence that supports it, particularly in adults and in HIV infection, is scarce. Preliminary clinical experience also suggests that the IM administration of PGB through increased needle gauges might improve its tolerability. The aim of the study to identify less painful ways of administering IM PGB in the treatment of syphilis in adults. Methods Multicenter, randomized, double-blinded clinical trial in patients diagnosed with primary syphilis that required a single IM injection of PGB 2400,00 IU. Patients were randomized to receive PGB diluted with 0.5 mL mepivacaine 1% (MV) or PGB alone, and both groups either with a long 19G or short 21G IM needle. The primary objective was the effect on local pain immediately after the administration through a visual scale questionnaire on pain (0 to 10). Results One hundred eight patients were included, 27 in each group. Ninety-four (94.4%) were male, and 41.7% were also HIV-infected. Mean age 36.6 years (SD 11). Significant differences in immediate pain intensity were observed when comparing the long 19G group with anesthesia (mean pain intensity, [MPI] 2.92 [CI 95% 1.08-4.07]) vs long 19G without anesthesia (MPI 5.56 [CI 95% 4.39-6.73), p < 0.001; and also between short 21G group with anesthesia (MPI 3.36 [CI 95% 2.22-4.50]) vs short 21G without anesthesia (MPI 5.06 [CI 95% 3.93-6.19]), p = 0.015). No significant differences in immediate pain were observed between 19G and 21G in the presence or absence of anesthesia (p = 1.0 in both cases). No differences were found between study arms after 6 and 24 h. Conclusions The IM administration of 1% mepivacaine-diluted PGB induces significantly less immediate local pain as compared to PGB alone. The needle gauge did not have any effect on the pain. Based on these results, we suggest anesthetic-diluted IM PGB as the standard treatment for primary syphilis. Trial registration EudraCT 2014-003969-24 (Date of registration 18/09/2014).


Author(s):  
S.F. Stinson ◽  
J.C. Lilga ◽  
M.B. Sporn

Increased nuclear size, resulting in an increase in the relative proportion of nuclear to cytoplasmic sizes, is an important morphologic criterion for the evaluation of neoplastic and pre-neoplastic cells. This paper describes investigations into the suitability of automated image analysis for quantitating changes in nuclear and cytoplasmic cross-sectional areas in exfoliated cells from tracheas treated with carcinogen.Neoplastic and pre-neoplastic lesions were induced in the tracheas of Syrian hamsters with the carcinogen N-methyl-N-nitrosourea. Cytology samples were collected intra-tracheally with a specially designed catheter (1) and stained by a modified Papanicolaou technique. Three cytology specimens were selected from animals with normal tracheas, 3 from animals with dysplastic changes, and 3 from animals with epidermoid carcinoma. One hundred randomly selected cells on each slide were analyzed with a Bausch and Lomb Pattern Analysis System automated image analyzer.


Author(s):  
Henry I. Smith ◽  
D.C. Flanders

Scanning electron beam lithography has been used for a number of years to write submicrometer linewidth patterns in radiation sensitive films (resist films) on substrates. On semi-infinite substrates, electron backscattering severely limits the exposure latitude and control of cross-sectional profile for patterns having fundamental spatial frequencies below about 4000 Å(l),Recently, STEM'S have been used to write patterns with linewidths below 100 Å. To avoid the detrimental effects of electron backscattering however, the substrates had to be carbon foils about 100 Å thick (2,3). X-ray lithography using the very soft radiation in the range 10 - 50 Å avoids the problem of backscattering and thus permits one to replicate on semi-infinite substrates patterns with linewidths of the order of 1000 Å and less, and in addition provides means for controlling cross-sectional profiles. X-radiation in the range 4-10 Å on the other hand is appropriate for replicating patterns in the linewidth range above about 3000 Å, and thus is most appropriate for microelectronic applications (4 - 6).


Author(s):  
Michel Troyonal ◽  
Huei Pei Kuoal ◽  
Benjamin M. Siegelal

A field emission system for our experimental ultra high vacuum electron microscope has been designed, constructed and tested. The electron optical system is based on the prototype whose performance has already been reported. A cross-sectional schematic illustrating the field emission source, preaccelerator lens and accelerator is given in Fig. 1. This field emission system is designed to be used with an electron microscope operated at 100-150kV in the conventional transmission mode. The electron optical system used to control the imaging of the field emission beam on the specimen consists of a weak condenser lens and the pre-field of a strong objective lens. The pre-accelerator lens is an einzel lens and is operated together with the accelerator in the constant angular magnification mode (CAM).


Author(s):  
M.A. Parker ◽  
K.E. Johnson ◽  
C. Hwang ◽  
A. Bermea

We have reported the dependence of the magnetic and recording properties of CoPtCr recording media on the thickness of the Cr underlayer. It was inferred from XRD data that grain-to-grain epitaxy of the Cr with the CoPtCr was responsible for the interaction observed between these layers. However, no cross-sectional TEM (XTEM) work was performed to confirm this inference. In this paper, we report the application of new techniques for preparing XTEM specimens from actual magnetic recording disks, and for layer-by-layer micro-diffraction with an electron probe elongated parallel to the surface of the deposited structure which elucidate the effect of the crystallographic structure of the Cr on that of the CoPtCr.XTEM specimens were prepared from magnetic recording disks by modifying a technique used to prepare semiconductor specimens. After 3mm disks were prepared per the standard XTEM procedure, these disks were then lapped using a tripod polishing device. A grid with a single 1mmx2mm hole was then glued with M-bond 610 to the polished side of the disk.


Author(s):  
E. R. Macagno ◽  
C. Levinthal

The optic ganglion of Daphnia Magna, a small crustacean that reproduces parthenogenetically contains about three hundred neurons: 110 neurons in the Lamina or anterior region and about 190 neurons in the Medulla or posterior region. The ganglion lies in the midplane of the organism and shows a high degree of left-right symmetry in its structures. The Lamina neurons form the first projection of the visual output from 176 retinula cells in the compound eye. In order to answer questions about structural invariance under constant genetic background, we have begun to reconstruct in detail the morphology and synaptic connectivity of various neurons in this ganglion from electron micrographs of serial sections (1). The ganglion is sectioned in a dorso-ventra1 direction so as to minimize the cross-sectional area photographed in each section. This area is about 60 μm x 120 μm, and hence most of the ganglion fit in a single 70 mm micrograph at the lowest magnification (685x) available on our Zeiss EM9-S.


Sign in / Sign up

Export Citation Format

Share Document