The rotating-saddle trap: a mechanical analogy to RF-electric-quadrupole ion trapping?

2002 ◽  
Vol 80 (12) ◽  
pp. 1433-1448 ◽  
Author(s):  
R I Thompson ◽  
T J Harmon ◽  
M G Ball

The rotating-saddle potential ball-bearing trap has long been used as a mechanical analogue to explain the operating principles of the Paul-type RF-electric-quadrupole ion trap. This paper outlines the shortcomings of this analogy, as well as explaining how and why this system remains an excellent tool for explaining ion-trap operation. The basic theory of the operating principles of the rotating-saddle trap is provided, which, unlike the Paul Trap is analytically solvable in the friction-free regime. In addition, some extensions to this theory are presented to examine such effects as friction. These results are compared with the equivalent results for Paul-Trap theory, as well as to experimental results measured with a rotating-saddle trap constructed at the University of Calgary. The technical details of this trap, an excellent tool for either lecture demonstrations or teaching laboratory experiments, are also presented, as well as some comments on building such a trap. PACS Nos.: 45.50-j, 01.50Pa, 32.80Pj


2020 ◽  
Vol 10 (7) ◽  
pp. 2222 ◽  
Author(s):  
Elia Perego ◽  
Lucia Duca ◽  
Carlo Sias

In the development of atomic, molecular, and optical (AMO) physics, atom-ion hybrid systems are characterized by the presence of a new tool in the experimental AMO toolbox: atom-ion interactions. One of the main limitations in state-of-the-art atom-ion experiments is represented by the micromotion component of the ions’ dynamics in a Paul trap, as the presence of micromotion in atom-ion collisions results in a heating mechanism that prevents atom-ion mixtures from undergoing a coherent evolution. Here, we report the design and the simulation of a novel ion trapping setup especially conceived of for integration with an ultracold atoms experiment. The ion confinement is realized by using an electro-optical trap based on the combination of an optical and an electrostatic field, so that no micromotion component will be present in the ions’ dynamics. The confining optical field is generated by a deep optical lattice created at the crossing of a bow-tie cavity, while a static electric quadrupole ensures the ions’ confinement in the plane orthogonal to the optical lattice. The setup is also equipped with a Paul trap for cooling the ions produced by photoionization of a hot atomic beam, and the design of the two ion traps facilitates the swapping of the ions from the Paul trap to the electro-optical trap.



2020 ◽  
Vol 126 (11) ◽  
Author(s):  
Julian Schmidt ◽  
Daniel Hönig ◽  
Pascal Weckesser ◽  
Fabian Thielemann ◽  
Tobias Schaetz ◽  
...  

AbstractWe study a method for mass-selective removal of ions from a Paul trap by parametric excitation. This can be achieved by applying an oscillating electric quadrupole field at twice the secular frequency $$\omega _{\text {sec}}$$ ω sec using pairs of opposing electrodes. While excitation near the resonance with the secular frequency $$\omega _{\text {sec}}$$ ω sec only leads to a linear increase of the amplitude with excitation duration, parametric excitation near $$2\, \omega _{\text {sec}}$$ 2 ω sec results in an exponential increase of the amplitude. This enables efficient removal of ions from the trap with modest excitation voltages and narrow bandwidth, therefore, substantially reducing the disturbance of ions with other charge-to-mass ratios. We numerically study and compare the mass selectivity of the two methods. In addition, we experimentally show that the barium isotopes with 136 and 137 nucleons can be removed from small ion crystals and ejected out of the trap while keeping $$^{138}\text {Ba}^{+}$$ 138 Ba + ions Doppler cooled, corresponding to a mass selectivity of better than $$\Delta m / m = 1/138$$ Δ m / m = 1 / 138 . This method can be widely applied to ion trapping experiments without major modifications since it only requires modulating the potential of the ion trap.



Atmosphere ◽  
2019 ◽  
Vol 10 (5) ◽  
pp. 232 ◽  
Author(s):  
Nikolić ◽  
Madzunkov ◽  
Darrach

The primary objective of the present study is to investigate the science return of future Venus atmosphere probe mission concepts using the Quadrupole Ion Trap (QIT) Mass Spectrometer (MS) Instrument (QIT-MS-I). We demonstrate the use of Monte-Carlo simulations in determining the optimal ion trapping conditions and focus the analysis on retrieving isotope ratios of noble gases in the model sample of the Venus atmosphere. Sampling takes place at a constant velocity of ~10 km/s between 112–110 km altitude and involves the use of getter pumps to remove all chemically-active species, retaining inert noble gases. The enriched sample is leaked into passively pumped vacuum chamber where it is analyzed by the QIT-MS sensor (QIT-MS-S) for 40 minutes. The simulated mass spectrum, as recorded by the QIT-MS-S, is deconvoluted using random walk algorithm to reveal relative abundances of noble gas isotopes. The required precision and accuracy of the deconvolution method is benchmarked against the a priori known model composition of the atmospheric sample.



Author(s):  
N.D. Scielzo ◽  
G. Li ◽  
M.G. Sternberg ◽  
G. Savard ◽  
P.F. Bertone ◽  
...  


Author(s):  
John W. Coleman

The injector to be described is a component in the Electron Injector-Linear Accelerator—Condenser Module for illumination used on the variable 100-500kV electron microscope being built at the Radio Corporation of America for the University of Virginia.The injector is an independently powered, autonomous unit, operating at a constant 6kV positive with respect to accelerator potential, thereby making beam current independent of accelerator potential. The injector provides for on-axis ion trapping to prolong filament lifetime, and incorporates a derived Einzel lens for optical integration into the overall illumination system for microscopy. Electrostatic beam deflectors for alignment are an integral part of the apparatus. The entire injector unit is cantilevered off a door for side loading, and is topped with a 4-filament turret released electrically but driven by a self-contained Negator spring motor.



2018 ◽  
pp. E51-E54
Author(s):  
Jennifer Beatty ◽  
Michael Peplowski ◽  
Noreen Singh ◽  
Craig Beers ◽  
Evan M Beck ◽  
...  

The Leader in Medicine (LIM) Program of the Cumming School of Medicine, University of Calgary, hosted its 7th Annual LIM Research Symposium on October 30, 2015 and participation grew once again, with a total of six oral and 99 posters presentations! Over 45 of our Faculty members also participated in the symposium. This year’s LIM Symposium theme was “Innovations in Medicine” and the invited guest speaker was our own Dr. Breanne Everett (MD/MBA). She completed her residency in plastic surgery at University of Calgary and holds both a medical degree and an MBA from the University of Calgary. In her inspiring talk, entitled “Marrying Business and Medicine: Toe-ing a Fine Line”, she described how she dealt with a clinical problem (diabetic foot ulcers), came up with an innovation that optimized patient care, started her own company and delivered her product to market to enhance the health of the community. She clearly illustrated how to complete the full circle, from identifying a clinical problem to developing and providing a solution that both enhances clinical care and patient health as well as reduces health care costs and hospital admissions. The research symposium was an outstanding success and the abstracts are included in companion article in CIM.



2021 ◽  
Vol 217 (1) ◽  
Author(s):  
J. Simcic ◽  
D. Nikolić ◽  
A. Belousov ◽  
D. Atkinson ◽  
C. Lee ◽  
...  

AbstractTo date, a variety of different types of mass spectrometers have been utilized on missions to study the composition of atmospheres of solar system bodies, including Venus, Mars, Jupiter, Titan, the moon, and several comets. With the increasing interest in future small probe missions, mass spectrometers need to become even more versatile, lightweight, compact, and sensitive.For in situ exploration of ice giant atmospheres, the highest priority composition measurements are helium and the other noble gases, noble gas isotopes, including 3He/4He, and other key isotopes like D/H. Other important but lower priority composition measurements include abundances of volatiles C, N, S, and P; isotopes 13C/12C, 15N/14N, 18O/17O/16O; and disequilibrium species PH3, CO, AsH3, GeH4, and SiH4. Required measurement accuracies are largely defined by the accuracies achieved by the Galileo (Jupiter) probe Neutral Mass Spectrometer and Helium Abundance Detectors, and current measurement accuracies of solar abundances.An inherent challenge of planetary entry probe mass spectrometers is the introduction of material to be sampled (gas, solid, or liquid) into the instrument interior, which operates at a vacuum level. Atmospheric entry probe mass spectrometers typically require a specially designed sample inlet system, which ideally provides highly choked, nearly constant mass-flow intake over a large range of ambient pressures. An ice giant descent probe would have to operate for 1-2 hours over a range of atmospheric pressures, possibly covering 2 or more orders of magnitude, from the tropopause near 100 mbar to at least 10 bars, in an atmospheric layer of depth beneath the tropopause of about 120 km at Neptune and about 150 km at Uranus.The Jet Propulsion Laboratory’s Quadrupole Ion Trap Mass Spectrometer (QITMS) is being developed to achieve all of these requirements. A compact, wireless instrument with a mass of only 7.5 kg, and a volume of 7 liters (7U), the JPL QITMS is currently the smallest flight mass spectrometer available for possible use on planetary descent probes as well as small bodies, including comet landers and surface sample return missions. The QITMS is capable of making measurements of all required constituents in the mass range of 1–600 atomic mass units (u) at a typical speed of 50 mass spectra per second, with a sensitivity of up to $10^{13}$ 10 13  counts/mbar/sec and mass resolution of $m/\Delta m=18000$ m / Δ m = 18000 at m/q = 40. (Throughout this paper we use the unit of m/q = u/e for the mass-to-charge ratio, where atomic mass unit and elementary charge are $1~\text{u} = 1.66\times 10^{-27}~\text{kg}$ 1 u = 1.66 × 10 − 27 kg and $1\text{e} = 1.6\times 10^{-19}$ 1 e = 1.6 × 10 − 19 C, respectively.) The QITMS features a novel MEMS-based inlet system driven by a piezoelectric actuator that continuously regulates gas flow at inlet pressures of up to 100 bar.In this paper, we present an overview of the QITMS capabilities, including instrument design and characteristics of the inlet system, as well as the most recent results from laboratory measurements in different modes of operation, especially suitable for ice giant atmospheres exploration.



The Analyst ◽  
2021 ◽  
Author(s):  
Fuxing Xu ◽  
Weimin Wang ◽  
Bingjun Qian ◽  
Liuyu Jin ◽  
Chuanfan Ding

The effective electric field radius is a fundamental parameter of ion trap which has great influence on ion trapping capability, signal intensity, mass range and some other properties of ion...



2021 ◽  
pp. 1-31
Author(s):  
DENISE HARDESTY SUTTON

When Harlequin Enterprises acquired British publisher Mills & Boon in 1972, the merged firm became the world’s dominant publisher of popular romance novels. Little is known, however, about the role that innovative marketing strategies played in the growth of these two romance publishing companies, especially their use of product sampling, direct mail, product standardization, and what was known at Mills & Boon as the “personal touch.” Through research in the Mills & Boon company archive at the University of Reading, the Grescoe Archive at the University of Calgary, as well as an analysis of company histories, trade publications, interviews, and marketing techniques, this study reveals how Harlequin and Mills & Boon took a different approach to product promotion than traditional publishers. Their innovation was to incorporate consumer goods marketing strategies, familiar to other industries, that disrupted and redefined standard practices of book publishers.



Sign in / Sign up

Export Citation Format

Share Document