Ionoacoustics: A new direct method for range verification

2015 ◽  
Vol 30 (17) ◽  
pp. 1540025 ◽  
Author(s):  
Katia Parodi ◽  
Walter Assmann

The superior ballistic properties of ion beams may offer improved tumor-dose conformality and unprecedented sparing of organs at risk in comparison to other radiation modalities in external radiotherapy. However, these advantages come at the expense of increased sensitivity to uncertainties in the actual treatment delivery, resulting from inaccuracies of patient positioning, physiological motion and uncertainties in the knowledge of the ion range in living tissue. In particular, the dosimetric selectivity of ion beams depends on the longitudinal location of the Bragg peak, making in vivo knowledge of the actual beam range the greatest challenge to full clinical exploitation of ion therapy. Nowadays, in vivo range verification techniques, which are already, or close to, being investigated in the clinical practice, rely on the detection of the secondary annihilation photons or prompt gammas, resulting from nuclear interaction of the primary ion beam with the irradiated tissue. Despite the initial promising results, these methods utilize a not straightforward correlation between nuclear and electromagnetic processes, and typically require massive and costly instrumentation. On the contrary, the long-term known, yet only recently revisited process of "ionoacoustics", which is generated by local tissue heating especially at the Bragg peak, may offer a more direct approach to in vivo range verification, as reviewed here.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Julie Lascaud ◽  
Pratik Dash ◽  
Matthias Würl ◽  
Hans-Peter Wieser ◽  
Benjamin Wollant ◽  
...  

AbstractThe characteristic depth dose deposition of ion beams, with a maximum at the end of their range (Bragg peak) allows for local treatment delivery, resulting in better sparing of the adjacent healthy tissues compared to other forms of external beam radiotherapy treatments. However, the optimal clinical exploitation of the favorable ion beam ballistic is hampered by uncertainties in the in vivo Bragg peak position. Ionoacoustics is based on the detection of thermoacoustic pressure waves induced by a properly pulsed ion beam (e.g., produced by modern compact accelerators) to image the irradiated volume. Co-registration between ionoacoustics and ultrasound imaging offers a promising opportunity to monitor the ion beam and patient anatomy during the treatment. Nevertheless, the detection of the ionoacoustic waves is challenging due to very low pressure amplitudes and frequencies (mPa/kHz) observed in clinical applications. We investigate contrast agents to enhance the acoustic emission. Ultrasound microbubbles are used to increase the ionoacoustic frequency around the microbubble resonance frequency. Moreover, India ink is investigated as a possible mean to enhance the signal amplitude by taking advantage of additional optical photon absorption along the ion beam and subsequent photoacoustic effect. We report amplitude increase of up to 200% of the ionoacoustic signal emission in the MHz frequency range by combining microbubbles and India ink contrast agents.


2009 ◽  
Vol 111 (5) ◽  
pp. 919-926 ◽  
Author(s):  
Bahram Andisheh ◽  
Anders Brahme ◽  
Mohammad A. Bitaraf ◽  
Panayiotis Mavroidis ◽  
Bengt K. Lind.

Object Radiation treatment of large arteriovenous malformations (AVMs) remains difficult and not very effective, even though seemingly promising methods such as staged volume treatments have been proposed by some radiation treatment centers. In symptomatic patients harboring large intracranial AVMs not amenable to embolization or resection, single-session high-dose stereotactic radiation therapy is a viable option, and the special characteristics of high-ionization-density light-ion beams offer several treatment advantages over photon and proton beams. These advantages include a more favorable depth-dose distribution in tissue, an almost negligible lateral scatter of the beam, a sharper penumbra, a steep dose falloff beyond the Bragg peak, and a higher probability of vascular response due to high ionization density and associated induction of endothelial cell proliferation and/or apoptosis. Carbon ions were recently shown to be an effective treatment for skull-base tumors. Bearing that in mind, the authors postulate that the unique physical and biological characteristics of light-ion beams should convey considerable clinical advantages in the treatment of large AVMs. In the present meta-analysis the authors present a comparison between light-ion beam therapy and more conventional modalities of radiation treatment with respect to these lesions. Methods Dose-volume histograms and data on peripheral radiation doses for treatment of large AVMs were collected from various radiation treatment centers. Dose-response parameters were then derived by applying a maximum likelihood fitting of a binomial model to these data. The present binomial model was needed because the effective number of crucial blood vessels in AVMs (the number of vessels that must be obliterated to effect a cure, such as large fistulous nidus vessels) is low, making the Poisson model less suitable. In this study the authors also focused on radiobiological differences between various radiation treatments. Results Light-ion Bragg-peak dose delivery has the precision required for treating very large AVMs as well as for delivering extremely sharp, focused beams to irregular lesions. Stereotactic light-ion radiosurgery resulted in better angiographically defined obliteration rates, less white-matter necrosis, lower complication rates, and more favorable clinical outcomes. In addition, in patients treated by He ion beams, a sharper dose-response gradient was observed, probably due to a more homogeneous radiosensitivity of the AVM nidus to light-ion beam radiation than that seen when low-ionization-density radiation modalities, such as photons and protons, are used. Conclusions Bragg-peak radiosurgery can be recommended for most large and irregular AVMs and for the treatment of lesions located in front of or adjacent to sensitive and functionally important brain structures. The unique physical and biological characteristics of light-ion beams are of considerable advantage for the treatment of AVMs: the densely ionizing beams of light ions create a better dose and biological effect distribution than conventional radiation modalities such as photons and protons. Using light ions, greater flexibility can be achieved while avoiding healthy critical structures such as diencephalic and brainstem nuclei and tracts. Treatment with the light ion He or Li is more suitable for AVMs ≤ 10 cm3, whereas treatment with the light ion Li, Be, or C may be more appropriate for larger AVMs. A binomial model based on the effective number of crucial vessels in the AVM may be used quite well to predict AVM obliteration probabilities for both small and large AVMs when therapies involving either photons or light ions are used.


2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
Ulrika Jakobsson ◽  
Ermei Mäkilä ◽  
Anu J. Airaksinen ◽  
Osku Alanen ◽  
Asenath Etilé ◽  
...  

Mesoporous silicon (PSi) is biocompatible and tailorable material with high potential in drug delivery applications. Here, we report of an evaluation of PSi as a carrier platform for theranostics by delivering a radioactive ion beam- (RIB-) based radioactive lanthanoid into tumors in a mouse model of prostate carcinoma. Thermally hydrocarbonized porous silicon (THCPSi) wafers were implanted with 159Dy at the facility for radioactive ion beams ISOLDE located at CERN, and the resulting [159Dy]THCPSi was postprocessed into particles. The particles were intratumorally injected into mice bearing prostate cancer xenografts. The stability of the particles was studied in vivo, followed by ex vivo biodistribution and autoradiographic studies. We showed that the process of producing radionuclide-implanted PSi particles is feasible and that the [159Dy]THCPSi particles stay stable and local inside the tumor over seven days. Upon release of 159Dy from the particles, the main site of accumulation is in the skeleton, which is in agreement with previous studies on the biodistribution of dysprosium. We conclude that THCPSi particles are a suitable platform together with RIB-based radiolanthanoids for theranostic purposes as they are retained after administration inside the tumor and the radiolanthanoid remains embedded in the THCPSi.


2016 ◽  
Vol 44 ◽  
pp. 1660217 ◽  
Author(s):  
R. Alarcon ◽  
D. Blyth ◽  
E. Galyaev ◽  
J. Holmes ◽  
L. Ice ◽  
...  

Particle detection instrumentation to address the in vivo verifications of proton dose and range is under development as part of a proton therapy research program focused on patient quality assurance. For in vivo proton range verification, a collimated gamma detector array is under construction to indirectly measure the position of the Bragg peak for each proton beam spot to within 1–2 mm precision. For dose flux verification, a proton fluence detector based on the technology of the Micromegas is under construction. This detector has an active area of about 100 cm2, coordinate resolution of better than 1 mm, and handling of incident proton beam fluxes of 109–1013 particles/s.


2006 ◽  
Vol 24 (3) ◽  
pp. 421-425 ◽  
Author(s):  
CLAUDE DEUTSCH ◽  
ROMAIN POPOFF

We have focused our attention on the stopping mechanisms involved in the recently proposed ion beam-target US program. This mechanism emphasizes out production of warm dense matter through pulsed ion beams, linearly accelerated, and interacting with thin foils in Bragg peak conditions. We reviewed the relevant energy loss mechanisms involved at moderate and low velocity ion projectile. Small velocities close to zero are given some attention.


Author(s):  
John F. Walker ◽  
J C Reiner ◽  
C Solenthaler

The high spatial resolution available from TEM can be used with great advantage in the field of microelectronics to identify problems associated with the continually shrinking geometries of integrated circuit technology. In many cases the location of the problem can be the most problematic element of sample preparation. Focused ion beams (FIB) have previously been used to prepare TEM specimens, but not including using the ion beam imaging capabilities to locate a buried feature of interest. Here we describe how a defect has been located using the ability of a FIB to both mill a section and to search for a defect whose precise location is unknown. The defect is known from electrical leakage measurements to be a break in the gate oxide of a field effect transistor. The gate is a square of polycrystalline silicon, approximately 1μm×1μm, on a silicon dioxide barrier which is about 17nm thick. The break in the oxide can occur anywhere within that square and is expected to be less than 100nm in diameter.


Author(s):  
Mark Denker ◽  
Jennifer Wall ◽  
Mark Ray ◽  
Richard Linton

Reactive ion beams such as O2+ and Cs+ are used in Secondary Ion Mass Spectrometry (SIMS) to analyze solids for trace impurities. Primary beam properties such as energy, dose, and incidence angle can be systematically varied to optimize depth resolution versus sensitivity tradeoffs for a given SIMS depth profiling application. However, it is generally observed that the sputtering process causes surface roughening, typically represented by nanometer-sized features such as cones, pits, pyramids, and ripples. A roughened surface will degrade the depth resolution of the SIMS data. The purpose of this study is to examine the relationship of the roughness of the surface to the primary ion beam energy, dose, and incidence angle. AFM offers the ability to quantitatively probe this surface roughness. For the initial investigations, the sample chosen was <100> silicon, and the ion beam was O2+.Work to date by other researchers typically employed Scanning Tunneling Microscopy (STM) to probe the surface topography.


1991 ◽  
Vol 223 ◽  
Author(s):  
Richard B. Jackman ◽  
Glenn C. Tyrrell ◽  
Duncan Marshall ◽  
Catherine L. French ◽  
John S. Foord

ABSTRACTThis paper addresses the issue of chlorine adsorption on GaAs(100) with respect to the mechanisms of thermal and ion-enhanced etching. The use of halogenated precursors eg. dichloroethane is also discussed in regard to chemically assisted ion beam etching (CAIBE).


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2864
Author(s):  
Eva Kröll ◽  
Miriana Vadalà ◽  
Juliana Schell ◽  
Simon Stegemann ◽  
Jochen Ballof ◽  
...  

Highly porous yttrium oxide is fabricated as ion beam target material in order to produce radioactive ion beams via the Isotope Separation On Line (ISOL) method. Freeze casting allows the formation of an aligned pore structure in these target materials to improve the isotope release. Aqueous suspensions containing a solid loading of 10, 15, and 20 vol% were solidified with a unidirectional freeze-casting setup. The pore size and pore structure of the yttrium oxide freeze-casts are highly affected by the amount of solid loading. The porosity ranges from 72 to 84% and the crosslinking between the aligned channels increases with increasing solid loading. Thermal aging of the final target materials shows that an operation temperature of 1400 °C for 96 h has no significant effect on the microstructure. Thermo-mechanical calculation results, based on a FLUKA simulation, are compared to measured compressive strength and forecast the mechanical integrity of the target materials during operation. Even though they were developed for the particular purpose of the production of short-lived radioactive isotopes, the yttria freeze-cast scaffolds can serve multiple other purposes, such as catalyst support frameworks or high-temperature fume filters.


Sign in / Sign up

Export Citation Format

Share Document