Clinical and radiobiological advantages of single-dose stereotactic light-ion radiation therapy for large intracranial arteriovenous malformations

2009 ◽  
Vol 111 (5) ◽  
pp. 919-926 ◽  
Author(s):  
Bahram Andisheh ◽  
Anders Brahme ◽  
Mohammad A. Bitaraf ◽  
Panayiotis Mavroidis ◽  
Bengt K. Lind.

Object Radiation treatment of large arteriovenous malformations (AVMs) remains difficult and not very effective, even though seemingly promising methods such as staged volume treatments have been proposed by some radiation treatment centers. In symptomatic patients harboring large intracranial AVMs not amenable to embolization or resection, single-session high-dose stereotactic radiation therapy is a viable option, and the special characteristics of high-ionization-density light-ion beams offer several treatment advantages over photon and proton beams. These advantages include a more favorable depth-dose distribution in tissue, an almost negligible lateral scatter of the beam, a sharper penumbra, a steep dose falloff beyond the Bragg peak, and a higher probability of vascular response due to high ionization density and associated induction of endothelial cell proliferation and/or apoptosis. Carbon ions were recently shown to be an effective treatment for skull-base tumors. Bearing that in mind, the authors postulate that the unique physical and biological characteristics of light-ion beams should convey considerable clinical advantages in the treatment of large AVMs. In the present meta-analysis the authors present a comparison between light-ion beam therapy and more conventional modalities of radiation treatment with respect to these lesions. Methods Dose-volume histograms and data on peripheral radiation doses for treatment of large AVMs were collected from various radiation treatment centers. Dose-response parameters were then derived by applying a maximum likelihood fitting of a binomial model to these data. The present binomial model was needed because the effective number of crucial blood vessels in AVMs (the number of vessels that must be obliterated to effect a cure, such as large fistulous nidus vessels) is low, making the Poisson model less suitable. In this study the authors also focused on radiobiological differences between various radiation treatments. Results Light-ion Bragg-peak dose delivery has the precision required for treating very large AVMs as well as for delivering extremely sharp, focused beams to irregular lesions. Stereotactic light-ion radiosurgery resulted in better angiographically defined obliteration rates, less white-matter necrosis, lower complication rates, and more favorable clinical outcomes. In addition, in patients treated by He ion beams, a sharper dose-response gradient was observed, probably due to a more homogeneous radiosensitivity of the AVM nidus to light-ion beam radiation than that seen when low-ionization-density radiation modalities, such as photons and protons, are used. Conclusions Bragg-peak radiosurgery can be recommended for most large and irregular AVMs and for the treatment of lesions located in front of or adjacent to sensitive and functionally important brain structures. The unique physical and biological characteristics of light-ion beams are of considerable advantage for the treatment of AVMs: the densely ionizing beams of light ions create a better dose and biological effect distribution than conventional radiation modalities such as photons and protons. Using light ions, greater flexibility can be achieved while avoiding healthy critical structures such as diencephalic and brainstem nuclei and tracts. Treatment with the light ion He or Li is more suitable for AVMs ≤ 10 cm3, whereas treatment with the light ion Li, Be, or C may be more appropriate for larger AVMs. A binomial model based on the effective number of crucial vessels in the AVM may be used quite well to predict AVM obliteration probabilities for both small and large AVMs when therapies involving either photons or light ions are used.

1980 ◽  
Vol 24 (1) ◽  
pp. 1-14 ◽  
Author(s):  
F. Winterberg

A pulsed, multi-stage, high-voltage accelerator is proposed which should be capable of producing intense ion beams of many million amperes and many million volts. Super ion beams produced by this type of accelerator can exceed the limiting Aifvén current for light ions, typically 107 A, at which beam pinching occurs. The beam pinching of these super-beams permits them to be precisely focused onto a thermonuclear target. With such an accelerator it seems to be possible to reach a beam voltage of 108 V with a beam current of 107 A. The resulting beam power of 1015 W should be more than sufficient to ignite a DT thermonuclear microexplosion. By the formation of a stable ion beam superpinch within a thermonuclear target, such a large beam power in conjunction with the strong self-magnetic field of the beam may even lead to the ignition of the DD and perhaps HB11 thermonuclear reactions.


2015 ◽  
Vol 30 (17) ◽  
pp. 1540025 ◽  
Author(s):  
Katia Parodi ◽  
Walter Assmann

The superior ballistic properties of ion beams may offer improved tumor-dose conformality and unprecedented sparing of organs at risk in comparison to other radiation modalities in external radiotherapy. However, these advantages come at the expense of increased sensitivity to uncertainties in the actual treatment delivery, resulting from inaccuracies of patient positioning, physiological motion and uncertainties in the knowledge of the ion range in living tissue. In particular, the dosimetric selectivity of ion beams depends on the longitudinal location of the Bragg peak, making in vivo knowledge of the actual beam range the greatest challenge to full clinical exploitation of ion therapy. Nowadays, in vivo range verification techniques, which are already, or close to, being investigated in the clinical practice, rely on the detection of the secondary annihilation photons or prompt gammas, resulting from nuclear interaction of the primary ion beam with the irradiated tissue. Despite the initial promising results, these methods utilize a not straightforward correlation between nuclear and electromagnetic processes, and typically require massive and costly instrumentation. On the contrary, the long-term known, yet only recently revisited process of "ionoacoustics", which is generated by local tissue heating especially at the Bragg peak, may offer a more direct approach to in vivo range verification, as reviewed here.


2006 ◽  
Vol 24 (3) ◽  
pp. 421-425 ◽  
Author(s):  
CLAUDE DEUTSCH ◽  
ROMAIN POPOFF

We have focused our attention on the stopping mechanisms involved in the recently proposed ion beam-target US program. This mechanism emphasizes out production of warm dense matter through pulsed ion beams, linearly accelerated, and interacting with thin foils in Bragg peak conditions. We reviewed the relevant energy loss mechanisms involved at moderate and low velocity ion projectile. Small velocities close to zero are given some attention.


Author(s):  
John F. Walker ◽  
J C Reiner ◽  
C Solenthaler

The high spatial resolution available from TEM can be used with great advantage in the field of microelectronics to identify problems associated with the continually shrinking geometries of integrated circuit technology. In many cases the location of the problem can be the most problematic element of sample preparation. Focused ion beams (FIB) have previously been used to prepare TEM specimens, but not including using the ion beam imaging capabilities to locate a buried feature of interest. Here we describe how a defect has been located using the ability of a FIB to both mill a section and to search for a defect whose precise location is unknown. The defect is known from electrical leakage measurements to be a break in the gate oxide of a field effect transistor. The gate is a square of polycrystalline silicon, approximately 1μm×1μm, on a silicon dioxide barrier which is about 17nm thick. The break in the oxide can occur anywhere within that square and is expected to be less than 100nm in diameter.


Author(s):  
Mark Denker ◽  
Jennifer Wall ◽  
Mark Ray ◽  
Richard Linton

Reactive ion beams such as O2+ and Cs+ are used in Secondary Ion Mass Spectrometry (SIMS) to analyze solids for trace impurities. Primary beam properties such as energy, dose, and incidence angle can be systematically varied to optimize depth resolution versus sensitivity tradeoffs for a given SIMS depth profiling application. However, it is generally observed that the sputtering process causes surface roughening, typically represented by nanometer-sized features such as cones, pits, pyramids, and ripples. A roughened surface will degrade the depth resolution of the SIMS data. The purpose of this study is to examine the relationship of the roughness of the surface to the primary ion beam energy, dose, and incidence angle. AFM offers the ability to quantitatively probe this surface roughness. For the initial investigations, the sample chosen was <100> silicon, and the ion beam was O2+.Work to date by other researchers typically employed Scanning Tunneling Microscopy (STM) to probe the surface topography.


1991 ◽  
Vol 223 ◽  
Author(s):  
Richard B. Jackman ◽  
Glenn C. Tyrrell ◽  
Duncan Marshall ◽  
Catherine L. French ◽  
John S. Foord

ABSTRACTThis paper addresses the issue of chlorine adsorption on GaAs(100) with respect to the mechanisms of thermal and ion-enhanced etching. The use of halogenated precursors eg. dichloroethane is also discussed in regard to chemically assisted ion beam etching (CAIBE).


2000 ◽  
Vol 93 (supplement_3) ◽  
pp. 113-119 ◽  
Author(s):  
D. Hung-Chi Pan ◽  
Wan-Yuo Guo ◽  
Wen-Yuh Chung ◽  
Cheng-Ying Shiau ◽  
Yue-Cune Chang ◽  
...  

Object. A consecutive series of 240 patients with arteriovenous malformations (AVMs) treated by gamma knife radiosurgery (GKS) between March 1993 and March 1999 was evaluated to assess the efficacy and safety of radiosurgery for cerebral AVMs larger than 10 cm3 in volume. Methods. Seventy-six patients (32%) had AVM nidus volumes of more than 10 cm3. During radiosurgery, targeting and delineation of AVM nidi were based on integrated stereotactic magnetic resonance (MR) imaging and x-ray angiography. The radiation treatment was performed using multiple small isocenters to improve conformity of the treatment volume. The mean dose inside the nidus was kept between 20 Gy and 24 Gy. The margin dose ranged between 15 to 18 Gy placed at the 55 to 60% isodose centers. Follow up ranged from 12 to 73 months. There was complete obliteration in 24 patients with an AVM volume of more than 10 cm3 and in 91 patients with an AVM volume of less than 10 cm3. The latency for complete obliteration in larger-volume AVMs was significantly longer. In Kaplan—Meier analysis, the complete obliteration rate in 40 months was 77% in AVMs with volumes between 10 to 15 cm3, as compared with 25% for AVMs with a volume of more than 15 cm3. In the latter, the obliteration rate had increased to 58% at 50 months. The follow-up MR images revealed that large-volume AVMs had higher incidences of postradiosurgical edema, petechiae, and hemorrhage. The bleeding rate before cure was 9.2% (seven of 76) for AVMs with a volume exceeding 10 cm3, and 1.8% (three of 164) for AVMs with a volume less than 10 cm3. Although focal edema was more frequently found in large AVMs, most of the cases were reversible. Permanent neurological complications were found in 3.9% (three of 76) of the patients with an AVM volume of more than 10 cm3, 3.8% (three of 80) of those with AVM volume of 3 to 10 cm3, and 2.4% (two of 84) of those with an AVM volume less than 3 cm3. These differences in complications rate were not significant. Conclusions. Recent improvement of radiosurgery in conjunction with stereotactic MR targeting and multiplanar dose planning has permitted the treatment of larger AVMs. It is suggested that gamma knife radiosurgery is effective for treating AVMs as large as 30 cm3 in volume with an acceptable risk.


Materials ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 2864
Author(s):  
Eva Kröll ◽  
Miriana Vadalà ◽  
Juliana Schell ◽  
Simon Stegemann ◽  
Jochen Ballof ◽  
...  

Highly porous yttrium oxide is fabricated as ion beam target material in order to produce radioactive ion beams via the Isotope Separation On Line (ISOL) method. Freeze casting allows the formation of an aligned pore structure in these target materials to improve the isotope release. Aqueous suspensions containing a solid loading of 10, 15, and 20 vol% were solidified with a unidirectional freeze-casting setup. The pore size and pore structure of the yttrium oxide freeze-casts are highly affected by the amount of solid loading. The porosity ranges from 72 to 84% and the crosslinking between the aligned channels increases with increasing solid loading. Thermal aging of the final target materials shows that an operation temperature of 1400 °C for 96 h has no significant effect on the microstructure. Thermo-mechanical calculation results, based on a FLUKA simulation, are compared to measured compressive strength and forecast the mechanical integrity of the target materials during operation. Even though they were developed for the particular purpose of the production of short-lived radioactive isotopes, the yttria freeze-cast scaffolds can serve multiple other purposes, such as catalyst support frameworks or high-temperature fume filters.


2004 ◽  
Vol 22 (1) ◽  
pp. 19-24 ◽  
Author(s):  
F. PEGORARO ◽  
S. ATZENI ◽  
M. BORGHESI ◽  
S. BULANOV ◽  
T. ESIRKEPOV ◽  
...  

Energetic ion beams are produced during the interaction of ultrahigh-intensity, short laser pulses with plasmas. These laser-produced ion beams have important applications ranging from the fast ignition of thermonuclear targets to proton imaging, deep proton lithography, medical physics, and injectors for conventional accelerators. Although the basic physical mechanisms of ion beam generation in the plasma produced by the laser pulse interaction with the target are common to all these applications, each application requires a specific optimization of the ion beam properties, that is, an appropriate choice of the target design and of the laser pulse intensity, shape, and duration.


1983 ◽  
Vol 23 ◽  
Author(s):  
G.J. Galvin ◽  
L.S. Hung ◽  
J.W. Mayer ◽  
M. Nastasi

ABSTRACTEnergetic ion beams used outside the traditional role of ion implantation are considered for semiconductor applications involving interface modification for self-aligned silicide contacts, composition modification for formation of buried oxide layers in Si on insulator structures and reduced disorder in high energy ion beam annealing for buried collectors in transistor fabrication. In metals, aside from their use in modification of the composition of near surface regions, energetic ion beams are being investigated for structural modification in crystalline to amorphous transitions. Pulsed beams of photons and electrons are used as directed energy sources in rapid solidification. Here, we consider the role of temperature gradients and impurities in epitaxial growth of silicon.


Sign in / Sign up

Export Citation Format

Share Document