VALIDITY OF THE RETROSPECTIVE APPLICATION OF OXFORD HIP AND KNEE SCORES

2015 ◽  
Vol 18 (01) ◽  
pp. 1550003
Author(s):  
Travis M. Falconer ◽  
Julie Headford ◽  
Stephen Edmondston ◽  
Piers J. Yates

The Oxford Hip Score (OHS) and Oxford Knee Score (OKS) are validated, reliable and reproducible outcome measures, however their use retrospectively has not been examined. The aim of this prospective cohort study was to examine the accuracy and reliability of patients' ability to recall their OHS and OKS in a retrospective manner. A total of 137 patients undergoing primary hip (40) or primary knee (97) arthroplasty with a mean age of 70.8 years (range, 47–88) and a mean time to follow up of 27.2 months (range, 6–46) were included in the study. The mean retrospective OHS and OKS decreased compared to the pre-operative score (OHS = 1.6 ± SD, p = 0.36, OKS = 4.7 ± SD, p < 0.001). There was only a weak positive relationship between the actual pre-operative scores and the retrospective scores (OHS: r2 = 0.30, OKS: r2 = 0.19). Bland–Altman analysis demonstrated 95% limits of agreement between scores of -19.9 to 23.1 for the OHS and -15.3 to 24.8 for the OKS. This study shows that patients are poor at retrospectively recalling their pre-operative OHS and OKS and therefore these scores should not be used in a retrospective manner.

2020 ◽  
Vol 34 (01) ◽  
pp. 115-120
Author(s):  
Ali Utkan ◽  
Emrah Caliskan ◽  
Batuhan Gencer ◽  
Bulent Ozkurt

AbstractAlthough there are numerous studies about routine histopathological analysis during arthroplasty surgeries, most of them showed that new diagnoses have rarely been obtained as a result. The aim of this study was to evaluate the efficacy of routine pathological analyses of synovia resected during primary total knee arthroplasty in patients with osteoarthritis and its relevance in the treatment process. Of the 47 included patients who were followed up prospectively, 26 patients had clinical and histopathological concordant diagnoses and 21 patients had discrepant diagnoses. Oxford knee score and visual analogue score were performed for all the patients. Kallgren-Lawrence score was used for radiological analyses. The Mann-Whitney U test was used to examine the differences between the abnormally distributed variables. Mean age was 65.9 ± 4.3 years (range, 50–89 years) and mean follow-up time was 19 ± 7.8 months (range, 6–39 months). Grade IV gonarthrosis was found to be statistically lower in the discrepant group (p = 0.046). The mean preoperative Oxford knee score was 16.8 ± 2.3 (range, 2–23) and the mean postoperative Oxford knee score was 44.6 ± 1.8 (range, 27–48; p = 0.016). Postoperative Oxford knee scores and VAS were significantly increased in both the concordant and discrepant groups (p = 0.026 and p = 0.035, p = 0.019 and p = 0.039, respectively). Resection and histopathologic analyses of the hypertrophied and inflamed synovium encountered during primary arthroplasty procedure should be performed. This examination not only could provide crucial information that may influence the postoperative follow-up guidelines but also could help us to expand our knowledge and awareness of rare diseases that might yield osteoarthritis. The level of evidence for the study is level II.


Author(s):  
Mera Usman Muhammed ◽  
Mayaki Abubakar Musa ◽  
Gambo Abdulrahman Abdullahi

This study was carried out to compare the digital rectal (DR) thermometer with non-contact infrared thermometer (IRT) measurements at two locations on the face in some large animal species. Two hundred and forty (240) animals comprising of equal numbers of three species (cattle, camel and horses) of varying age and either sex was used. The IR temperature was taken from two sites [frontal (FIRT) and temporal (TIRT) region] on the animal face. The mean IR temperatures (FIRT and TIRT) were higher than the RT in all the animal species. The two thermometers correlate poorly in all the animal species. Bland-Altman analysis showed high biases and limits of agreement not acceptable for clinical purposes. In conclusion, IRT seems to offer a quick and easy way to determine the animal temperature but clinically it cannot be used interchangeably with DR thermometer at the moment for body temperature measurement in these animal species.


2020 ◽  
Vol 86 (2) ◽  
pp. 33-38
Author(s):  
Marcin Para ◽  
◽  
Paweł Bartosz ◽  
Maciej Kogut ◽  
Gracjan Suchodolski ◽  
...  

Introduction. Complications after arthroplasty often result in irreversible disability. In some cases, for the extremity to be salvaged, permanent knee joint arthrodesis is a last-chance procedure. Modular implant design simplifies surgical technique and knee arthrodesis without bone-on-bone contact, immediately provides full weight bearing and restores limb length and alignment. Puropose. The aim of this article was to perform a clinical evaluation of patients after knee arthrodesis with a dedicated modular intramedullary nail without bone-on-bone contact after a failed infected total knee arthroplasty. Methods. Between 2017 and 2021, 17 patients were treated with knee arthrodesis with a modular nail after a septic complication of total knee arthroplasty. Clinical evaluation of 15 patients was obtained during a follow-up visit, including: the pain severity using the Visual Analog Scale (VAS), physical function using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Oxford Knee Score, gait independence, and the shortening of the affected limb in relation to the other one. Results. The mean follow-up duration was 1.4 years. The group included 11 women and 4 men with an average of 69.3 (57–84) years. All nails were cemented. There was one recurrence of infection. The mean VAS pain score was 2.73, also 4 patients felt no pain at all. The average functional score on the WOMAC scale was 36.4 (14–60) and for the Oxford Knee Score was 26.5 (15–41). Each patient achieved an independent gait. All patients reported the necessity of use of crutches outside home. The average limb shortening was 2.05 cm (0.5–3.0). In addition, 14 of the 15 patients positively evaluated the procedure results and if they had to, they would again decide on this form of treatment. During follow-up, no complication or problems with implants used were observed. Conclusions. Knee arthrodesis with modular nail offers an acceptable functional result and gives a chance of salvaging a limb in complex septic complications of TKA.


PeerJ ◽  
2017 ◽  
Vol 5 ◽  
pp. e4132 ◽  
Author(s):  
Rashad Zayat ◽  
Andreas Goetzenich ◽  
Ju-Yeon Lee ◽  
HeeJung Kang ◽  
So-Hyun Jansen-Park ◽  
...  

BackgroundBedside non-invasive techniques, such as radial artery tonometry, to estimate hemodynamic parameters have gained increased relevance as an attractive alternative and efficient method to measure hemodynamics in outpatient departments. For our pilot study, we sought to compare cardiac output (CO), and stroke volume (SV) estimated from a radial artery tonometry blood pressure pulse analyzer (BPPA) (DMP-Life, DAEYOMEDI Co., Gyeonggi-do, South Korea) to pulsed-wave Doppler (PWD) echocardiography derived parameters.MethodsFrom January 2015 to December 2016, all patients scheduled for coronary artery bypass (CABG) surgery at our department were screened. Exclusion criteria were, inter alia, moderate to severe aortic- or Mitral valve disease and peripheral arterial disease (PAD) > stage II. One hundred and seven patients were included (mean age 66.1 ± 9.9, 15 females, mean BMI 27.2 ± 4.1 kg/m2). All patients had pre-operative transthoracic echocardiography (TTE). We measured the hemodynamic parameters with the BPPA from the radial artery, randomly before or after TTE. For the comparison between the measurement methods we used the Bland-Altman test and Pearson correlation.ResultsMean TTE-CO was 5.1 ± 0.96 L/min, and the mean BPPA-CO was 5.2 ± 0.85 L/min. The Bland-Altman analysis for CO revealed a bias of −0.13 L/min and SD of 0.90 L/min with upper and lower limits of agreement of −1.91 and +1.64 L/min. The correlation of CO measurements between DMP-life and TTE was poor (r = 0.501,p < 0.0001). The mean TTE-SV was 71.3 ± 16.2 mL and the mean BPPA-SV was 73.8 ± 19.2 mL. SV measurements correlated very well between the two methods (r = 0.900,p < 0.0001). The Bland-Altman analysis for SV revealed a bias of −2.54 mL and SD of ±8.42 mL and upper and lower limits of agreement of −19.05 and +13.96 mL, respectively.ConclusionOur study shows for the first time that the DMP-life tonometry device measures SV and CO with reasonable accuracy and precision of agreement compared with TTE in preoperative cardiothoracic surgery patients. Tonometry BPPA are relatively quick and simple measuring devices, which facilitate the collection of cardiac and hemodynamic information. Further studies with a larger number of patients and with repeated measurements are in progress to test the reliability and repeatability of DMP-Life system.


2010 ◽  
Vol 92 (6) ◽  
pp. 467-471 ◽  
Author(s):  
Shelain Patel ◽  
Fahad S Hossain ◽  
Bruce Paton ◽  
Fares S Haddad

INTRODUCTION The purpose of this study was to determine if a multimodal programme including physiotherapy and education could improve the symptoms of osteoarthritis of the knee across various severities of disease. PATIENTS AND METHODS Seventy-two patients with osteoarthritis of the knee confirmed on radiographic evidence were referred over a 13-month period for a lower limb programme which consisted of 12 classes over 6 weeks of group physiotherapy and included education on osteoarthritis, diet and exercise. Six patients went on to have joint arthroplasty at a mean time of 6.5 months with three placed on the waiting list during follow-up. RESULTS Pre-intervention, the mean WOMAC score was 42.0 and the mean Oxford Knee Score was 32.8. Post-intervention at a mean follow-up of 12 months, the mean WOMAC score was 31.6 and the mean Oxford Knee Score 24.3. The change in scores following intervention was statistically significant (P < 0.01). Using the WOMAC scoring system, the greatest effect size was seen in patients with Kellgren–Lawrence grade IV whilst using the Oxford knee scoring system, the greatest effect size was seen in patients with Kellgren–Lawrence grade II. CONCLUSIONS At 12 months, a multimodal programme of non-operative interventions has an excellent impact upon the symptoms of osteoarthritis of the knee with improved patient-reported scores. The level of improvement cannot be inferred from the radiographic grade of osteoarthritis. This modality could be considered for all patients with mild-to-moderate osteoarthritis of the knee.


Author(s):  
Veenesh Selvaratnam ◽  
Andrew Cattell ◽  
Keith S. Eyres ◽  
Andrew D. Toms ◽  
Jonathan R. P. Phillips ◽  
...  

AbstractPatello-femoral arthroplasty (PFA) is successful in a selected group of patients and yields a good functional outcome. Robotic-assisted knee arthroplasty has been shown to provide better implant positioning and alignment. We aim to report our early outcomes and to compare Mako's (Robotic Arm Interactive Orthopaedic System [RIO]) preoperative implant planning position to our intraoperative PFA implant position. Data for this study was prospectively collected for 23 (two bilateral) patients who underwent robotic-assisted PFA between April 2017 and May 2018. All preoperative implant position planning and postoperative actual implant position were recorded. Presence of trochlear dysplasia and functional outcome scores were also collected. There were 17 (two bilateral) female and 6 male patients with a mean age of 66.5 (range: 41–89) years. The mean follow-up period was 30 (range: 24–37) months. Eighteen knees (72%) had evidence of trochlear dysplasia. The anterior trochlear line was on average, 7.71 (range: 3.3–11.3) degrees, internally rotated to the surgical transepicondylar axis and on average 2.9 (range: 0.2–6.5) degrees internally rotated to the posterior condylar line. The preoperative planning range was 4-degree internal to 4-degree external rotation, 4-degree varus to 6-degree valgus, and 7-degree flexion to 3-degree extension. The average difference between preoperative planning and intraoperative implant position was 0.43 degrees for rotation (r = 0.93), 0.99 degrees for varus/valgus (r = 0.29), 1.26 degrees for flexion/extension (r = 0.83), and 0.34 mm for proudness (r = 0.80). Six patients (24%) had a different size component from their preoperative plan (r = 0.98). The mean preoperative Oxford Knee Score (OKS) was 16 and the mean postoperative OKS was 42. No patient had implant-related revision surgery or any radiological evidence of implant loosening at final follow-up. Our early results of robotic PFA are promising. Preoperative Mako planning correlates closely with intraoperative implant positioning. Longer follow-up is needed to assess long-term patient outcomes and implant survivorship.


2021 ◽  
pp. 1-7
Author(s):  
Naomi Vather-Wu ◽  
Matthew D. Krasowski ◽  
Katherine D. Mathews ◽  
Amal Shibli-Rahhal

Background: Expert guidelines recommend annual monitoring of 25-hydroxyvitamin D (25-OHD) and maintaining 25-OHD ≥30 ng/ml in patients with dystrophinopathies. Objective: We hypothesized that 25-OHD remains stable and requires less frequent monitoring in patients taking stable maintenance doses of vitamin D. Methods: We performed a retrospective cohort study, using the electronic health record to identify 26 patients with dystrophinopathies with a baseline 25-OHD ≥30 ng/mL and at least one additional 25-OHD measurement. These patients had received a stable dose of vitamin D for ≥3 months prior to their baseline 25-OHD measurement and throughout follow-up. The main outcome measured was the mean duration time the subjects spent with a 25-OHD ≥30 ng/mL. Results: Only 19% of patients dropped their 25-OHD to <  30 ng/ml, with a mean time to drop of 33 months and a median nadir 25-OHD of 28 ng/mL. Conclusions: These results suggest that measurement of 25-OHD every 2–2.5 years may be sufficient in patients with a baseline 25-OHD ≥30 ng/mL and who are on a stable maintenance dose of vitamin D. Other patients may require more frequent assessments.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Sujin Kang

Abstract Background The degree to which a validated instrument is able to detect clinically significant change over time is an important issue for the better management of hip or knee replacement surgery. This study examines the internal responsiveness of the EQ-5D-3L, the Oxford Hip Score (OHS), and the Oxford Knee Score (OKS) by various methods. Data from NHS patient-reported outcome measures (PROMs) linked to the Hospital Episodes Statistics (HES) dataset (2009–2015) was analysed for patients who underwent primary hip surgery (N = 181,424) and primary knee surgery (N = 191,379). Methods Paired data-specific univariate responsiveness was investigated using the standardized response mean (SRM), the standardized effect size (SES), and the responsiveness index (RI). Multivariate responsiveness was furthermore examined using the defined capacity of benefit score (i.e. paired data-specific MCID), adjusting baseline covariates such as age, gender, and comorbidities in the Box-Cox regression models. The observed and predicted percentages of patient improvement were examined both as a whole and by the patients' self-assessed transition level. Results The results showed that both the OHS and the OKS demonstrated great univariate and multivariate responsiveness. The percentages of the observed (predicted) total improvement were high: 51 (54)% in the OHS and 73 (58)% in OKS. The OHS and the OKS showed distinctive differences in improvement by the 3-level transition, i.e. a little better vs. about the same vs. a little worse. The univariate responsiveness of the EQ-5D-3L showed moderate effects in total by Cohen’s thresholds. The percentages of improvement in the EQ-5D-3L were moderate: 44 (48)% in the hip and 42 (44)% for the knee replacement population. Conclusions Distinctive percentage differences in patients’ perception of improvement were observed when the paired data-specific capacity of benefit score was applied to examine responsiveness. This is useful in clinical practice as rationale for access to surgery at the individual-patient level. This study shows the importance of analytic methods and instruments for investigation of the health status in hip and/or knee replacement surgery. The study finding also supports the idea of using a generic measure along with the disease-specific instruments in terms of cross-validation.


2021 ◽  
Vol 28 (Supplement_1) ◽  
Author(s):  
J Borrego Rodriguez ◽  
C Palacios Echevarren ◽  
S Prieto Gonzalez ◽  
JC Echarte Morales ◽  
R Bergel Garcia ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. INTRODUCTION CRH in patients with ischemic heart disease is recommended by the different clinical practice guidelines with an IA level of evidence, with an important role in reducing cardiovascular mortality and hospital readmissions during follow-up. OBJECTIVE The goal of this study is to show the 4-year clinical results of a population of patients who participated in an CRH program after an Acute Coronary Syndrome (ACS). METHODS Between May/2014 and September/2017, 221 patients who had recently presented an ACS completed the 12 weeks of phase II of the CRH program at our center. In May/2020 we collected epidemiological, clinical and echocardiographic information at the time of the acute cardiovascular event; and we evaluate the current vital status of the patients and the incidence of readmissions for: angina, HF, new ACS, or arrhythmic events. RESULTS Of the 221 patients, 182 were men (82%). The mean age of our population was 58.3 ± 7.8 years. 58% (129 patients) suffered from ST-elevation ACS. The mean time of hospital stay was 6.20 ± 2.9 days. An echocardiogram was performed at discharge, which showed an average LVEF of 56 ± 6%. Eight patients (4%) developed early Ventricular Fibrilation (VF) during the acute phase of ACS. Among the classic CVRF, smoking (79%) was the most prevalent, followed by dyslipidemia (53%) and hypertension (47%). The mean time from hospital discharge to the start of phase II RHC was 42 ± 16 days. The overall incidence of events was 9%: 10 patients suffered reinfarction during follow-up, and 7 were readmitted for unstable angina, all of whom underwent PCI; no patient was admitted for HF; and none of the 8 patients with early VF had a new tachyarrhythmia, registering a single admission for VT during follow-up. None of the patients had sustained ventricular tachyarrhythmias during exercise-training. At the mean 4.5-year follow-up, 218 patients were still alive (98%). CONCLUSION The incidence of CV events in the follow-up of our cohort was low, which can be explained by the fact that it is a young population, with an LVEF at low limits of normality at discharge, which is one of the most important predictors in the prognosis after an ischemic event. As an improvement, we must shorten the time until the start of phase II of the program. CRH shows once again its clinical benefit after an ACS, in consonance with the existing evidence. Abstract Figure. Outcomes of a CRH program.


Sign in / Sign up

Export Citation Format

Share Document