Semiconductor-Based Biosensor Functionalized with Jacalin for Detection of Secretory IgA in Sweat Sample

Keyword(s):  
npj Vaccines ◽  
2021 ◽  
Vol 6 (1) ◽  
Author(s):  
Changjiao Gan ◽  
Wenbo Luo ◽  
Yunzhou Yu ◽  
Zhouguang Jiao ◽  
Sha Li ◽  
...  

AbstractBotulinum neurotoxin (BoNT), produced by Clostridium botulinum, is generally known to be the most poisonous of all biological toxins. In this study, we evaluate the protection conferred by intratracheal (i.t.) inoculation immunization with recombinant Hc subunit (AHc) vaccines against aerosolized BoNT/A intoxication. Three AHc vaccine formulations, i.e., conventional liquid, dry powder produced by spray freeze drying, and AHc dry powder reconstituted in water are prepared, and mice are immunized via i.t. inoculation or subcutaneous (s.c.) injection. Compared with s.c.-AHc-immunized mice, i.t.-AHc-immunized mice exhibit a slightly stronger protection against a challenge with 30,000× LD50 aerosolized BoNT/A. Of note, only i.t.-AHc induces a significantly higher level of toxin-neutralizing mucosal secretory IgA (SIgA) production in the bronchoalveolar lavage of mice. In conclusion, our study demonstrates that the immune protection conferred by the three formulations of AHc is comparable, while i.t. immunization of AHc is superior to s.c. immunization against aerosolized BoNT/A intoxication.


1973 ◽  
Vol 82 (3) ◽  
pp. 359-369 ◽  
Author(s):  
John F. Schmedtje ◽  
Ann F. Batts

The localization of IgA, IgG, IgM, SP and the relationships of plasma cells and lymphocytes to blood vessels in the tonsillar crypt epithelium were investigated. Immunofluorescent techniques were used that included antisera specific for the two antigenic determinants of external secretory IgA, namely, 4s SP and 7s IgA, and also antisera specific for 7s IgG and 19s IgM. The secretory piece was absent in the crypt epithelium and in most of the crypt lumen. Aggregations of plasmacyte series cells, containing either IgG, IgA, or IgM were present in the crypt epithelium. Mature plasma cells of these aggregations abutted against the walls of blood sinusoids located in the epithelium, which suggested secretion into these sinusoids. All three immunoglobulins were also identified between epithelial cells and small lymphocytes. Postcapillary venules with emigrating small lymphocytes abounded in sub-epithelial sites, and were present at the lower border zone of the epithelium. Lymphocytes in shapes of diapedesis were observed in the endothelium of epithelial blood sinusoids. These observations are in accord with the hypothesis that a “circulation” of many lymphocytes occurs in the epithelium facilitating the activation of any one genetically committed lymphocyte.


2012 ◽  
Vol 19 (10) ◽  
pp. 1593-1596 ◽  
Author(s):  
Ravinder Kaur ◽  
Thomas Kim ◽  
Janet R. Casey ◽  
Michael E. Pichichero

ABSTRACTThe human middle ear is devoid of any immunocompetent cells in normal mucosa. We sought to determine the source of antibody present in the middle ear of children. Total IgG, IgA, and secretory IgA antibodies were determined by enzyme-linked immunosorbent assay from the nasopharyngeal, middle ear, and serum samples of children with acute otitis media. The two-dimensional gel electrophoresis pattern of the entire array of IgA antibodies in the nasal wash (NW) and middle ear fluid (MEF) was compared from the MEF and NW samples using isoelectric focusing and Western blotting. The total IgG and IgA antibodies in the MEF and NW samples of 137 children were compared. The ratio of IgG to IgA in the MEF was significantly different (P< 0.008) compared to NW because IgA levels were higher and IgG levels lower in NW. The IgG/IgA ratio of MEF resembled serum consistent with transudation to the MEF. Small amounts of secretory IgA were detected in MEF but the electrophoresis patterns of the entire array of IgA antibodies in the MEF and NW were virtually identical in each child evaluated; thus, IgA in MEF derived predominantly from serum and the nasopharynx by reflux via the Eustachian tube. The IgG/IgA antibody levels in the MEF and the same composition of IgA antibody in the MEF and NW identifies the predominant source of antibody in the MEF as a transudate of serum combined with nasal secretions refluxed from the nasopharynx in children.


2021 ◽  
Vol 331 ◽  
pp. 1-13
Author(s):  
Venugopal Bhaskara ◽  
Maria Trinidad Leal ◽  
Jacqueline Seigner ◽  
Theresa Friedrich ◽  
Emanuel Kreidl ◽  
...  

Chemosensors ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 169
Author(s):  
Francesca Mazzara ◽  
Bernardo Patella ◽  
Chiara D’Agostino ◽  
Maria Giuseppina Bruno ◽  
Sonia Carbone ◽  
...  

Nowadays, we are assisting in the exceptional growth in research relating to the development of wearable devices for sweat analysis. Sweat is a biofluid that contains useful health information and allows a non-invasive, continuous and comfortable collection. For this reason, it is an excellent biofluid for the detection of different analytes. In this work, electrochemical sensors based on polyaniline thin films deposited on the flexible substrate polyethylene terephthalate coated with indium tin oxide were studied. Polyaniline thin films were abstained by the potentiostatic deposition technique, applying a potential of +2 V vs. SCE for 90 s. To improve the sensor performance, the electronic substrate was modified with reduced graphene oxide, obtained at a constant potential of −0.8 V vs. SCE for 200 s, and then polyaniline thin films were electrodeposited on top of the as-deposited substrate. All samples were characterized by XRD, SEM, EDS, static contact angle and FT-IR/ATR analysis to correlate the physical-chemical features with the performance of the sensors. The obtained electrodes were tested as pH sensors in the range from 2 to 8, showing good behavior, with a sensitivity of 62.3 mV/pH, very close to a Nernstian response, and a reproducibility of 3.8%. Interference tests, in the presence of competing ions, aimed to verify the selectivity, were also performed. Finally, a real sweat sample was collected, and the sweat pH was quantified with both the proposed sensor and a commercial pH meter, showing an excellent concordance.


1973 ◽  
Vol 82 (3) ◽  
pp. 297-301 ◽  
Author(s):  
Robert W. Veltri ◽  
Philip M. Sprinkle

The middle ear fluids of seven patients with bilateral, and five patients with unilateral serous otitis media (SOM), were demonstrated to be microbiologically sterile when assessed for the presence of bacteria, mycoplasma, viruses, and fungi. The concentrations of immunoglobulins G, M, A, D, and lysozyme (muramidase) were determined in the serum and middle ear fluids. Lysozyme levels of middle ear aspirates were found to be elevated in SOM patients. The elevated levels of lysozyme in combination with the antibody-containing classes of immunoglobulins may explain the microbiologically sterile condition of the middle ear fluids of SOM patients. Also, the elevated lysozyme concentrations in middle ear fluids may indicate the previous presence of neutrophils and hence a previous inflammatory insult. The increased levels of IgA demonstrated in middle ear fluids may indicate local synthesis of secretory IgA by secretory cells of Eustachian tube and middle ear. The closed Eustachian tube, partial vacuum conditions and absence of a portal of exit for accumulated serous fluids are offered as a possible explanation for SOM.


Sign in / Sign up

Export Citation Format

Share Document