scholarly journals Assessment of Quality of Groundwater in Kandarvakottai and Karambakudi Areas of Pudukkottai District, Tamilnadu, India

2009 ◽  
Vol 6 (3) ◽  
pp. 898-904
Author(s):  
D. Ilangeswaran ◽  
R. Kumar ◽  
D. Kannan

Various samples of groundwater were collected from different areas of Kandarvakottai and Karambakudi of Pudukkottai District, Tamilnadu and analyzed for their physicochemical characteristics. The results of this analysis were compared with the water quality standards of ISI, WHO and CPHEEO. In this analysis the various physicochemical parameters such as pH, electrical conductivity, turbidity, total dissolved solids, Cl-, F-, SO42-, PO43-, NO3-, NO2-, CN-, Nas+, K+, NH3, Mn, Fe, Ca & Mg hardnessetc., were determined using standard procedures. The quality of groundwater samples were discussed with respect to these parameters and thus an attempt were made to ascertain the quality of groundwater used for drinking and cooking purposes in and around Kandarvakottai and Karambakudi areas.

2010 ◽  
Vol 7 (2) ◽  
pp. 473-478 ◽  
Author(s):  
G. Raja ◽  
P. Venkatesan

Various samples of groundwater were collected from different areas in and around the Punnam village of Karur District, India and analyzed for their physicochemical characteristics. The results of this analysis were compared with the water quality standards of WHO and CPHEEO. In this analysis the various physicochemical parameters such as pH, electrical conductivity, turbidity, total dissolved solids, Cl-, F-, SO42-, NO3-, Na+, K+, Fe, Cr, calcium and magnesiumetc., were determined using standard procedures. The quality of groundwater samples were discussed with respect to these parameters and thus an attempt were made to ascertain the quality of groundwater used for drinking and cooking purposes in the sampling areas.


2011 ◽  
Vol 8 (1) ◽  
pp. 53-58 ◽  
Author(s):  
V. T. Patil ◽  
P. R. Patil

Groundwater samples (Three open wells, three tube wells) were collected from six different locations around Amalner town and analyzed during November 2007-February 2008. Fifteen physicochemical parameters were analyzed and the results were compared with water quality standards prescribed by WHO and ISI 10500-91. In the present study, two water samples (one open well, one tube well) showed high EC, TDS, TA, TH values indicating poor water quality. The correlation coefficients were calculated. The significance of the results is further discussed.


Author(s):  
Natasha Berendonk Handam ◽  
José Augusto Albuquerque dos Santos ◽  
Antonio Henrique Almeida de Moraes Neto ◽  
Maria De Fátima Leal Alencar ◽  
Caroline Ferraz Ignacio ◽  
...  

   The study analyzed the quality of drinking water used in Brazilian urban slum residences according to the standards established in Brazilian regulations. Bacteriological (n=231) and physicochemical parameters (n=134) were analyzed, as the Standard Methods for the Examination of Water and Wastewater establishes. The results revealed that contaminants in the water consumed, for the most part, exceed the limits of drinking water quality standards, putting the population's health at risk and reinforcing the urgency of the need for public policies.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Arun Kumar Shrestha ◽  
Nabin Basnet

Ten different water samples were collected from Ratuwa River and its tributaries. The laboratory test was carried out by standard procedures (APHA methods), and the measured values were compared with the Nepal standard recommended by Nepal Drinking Water Quality Standards (NDWQS). Statistical analysis also had been used to calculate the correlation coefficients and to plot the regression equations of various parameters with electrical conductivity. The aim of the study was to identify the parameters that affect the electrical conductivity and evaluate the percentage contribution of these parameters. The correlation matrix shows that color, total dissolved solids (TDS), chloride (Cl), fluoride (F), total phosphorus (TP), total alkalinity (TA), calcium (Ca), magnesium (Mg), sodium (Na), and dissolved oxygen (DO) have a significant effect on the electrical conductivity (EC). Among these parameters, TDS has the highest contribution (39.65%) followed by total alkalinity (23.5%), total hardness (19.9%), chlorine (6.5%), and calcium (5.5%) ions, respectively. However, color, TP, fluoride, and DO have almost 1.45% contribution to the electrical conductivity.


Author(s):  
I. W. Agus Eka Subrata Jaya ◽  
I Wayan Suarna ◽  
I Wayan Redi Aryanta

Research has been conducted to determine the quality of shallow groundwater (dug-wells and shallow bore-wells) and the local communities opinions around the landfill Suwung. The method of determining the station was done by purposive sampling, where the station sampling was determined by selecting a place which was expected to represent the whole area.Water sampling of dug-wells was conducted by using a water sampler and the shallow bore-wells using a 2-liter bottle. Data was analyzed by descriptive comparative referenceto class I water quality of the Bali Governor Regulation No.8 of 2007. The public opinion data was obtained by using aquesioner filled by respondents who have and use wells and shallow bore wells for their daily needsand it was analyzed by using frequency distribution tables.The results showed that the quality of shallow groundwater (dug-wells and shallow bore-wells) did not meet water quality standards in accordance with the rules of the class defined in the Governor of Bali Regulation No. 8 of 2007. The water pollution index (PI) of dug-wells at a distance of 1-400 meters was in hearily polluted category, while water fromshallow bore-wells drilled at a distance of 1-200 meters was in the category of hearily polluted and at a distance of 201-400 meters was in the category of medium polluted.There was an increasing range of groundwater quality deterioration in 1997, 2008 and 2014. In 1997, contaminated shallow groundwater has occured at a distance of 80 meters, while in 2008, the pollution has occurred up to a distance of 375 meters and in the year of 2014 the contamination occurred from a distance of 1 meter to 400 meters. The average of score Pollution Index (PI) of Water wells in the year of 2008 amounted to 14.55, while in 2014 up to 15.44. It is estimated that the water quality of dug-wells and bore-wells will meet the quality standards in accordance with the value of the pollution index at a distance of over 5000 meters and 750 meters of the Suwung landfill waste.Most of the respondents who live in the vicinity Suwung landfill waste tend to give an opinion that the shallow groundwater (dug-wells and shallow bore-wells) has decreased quality as drinking water. Approximately 75% of respondents thought that the well water in their environment has been reduced in quality.


2009 ◽  
Vol 6 (3) ◽  
pp. 909-914 ◽  
Author(s):  
K. Karunakaran ◽  
P. Thamilarasu ◽  
R. Sharmila

Groundwater samples collected at different locations in and around Namakkal were analyzed for their physicochemical characteristics. Ten locations of groundwater samples were collected and studied for every two month for the period June-2007 to December-2007. The present investigation is focused on the determination of physicochemical parameters such as temperature, taste, turbidity, electrical conductivity, pH, hardness, total solids, total dissolved solids, total suspended solids, chlorides, sulphate, nitrate, fluorides, dissolved oxygen, sodium, potassium andE.colibacterium. Groundwater suitability for domestic and irrigation purposes was examined by using WHO and BIS standards, which indicate the groundwater in a few areas, were not much suitable for domestic and agriculture purposes. Thus the objective of this study is to identify the quality of groundwater especially in the town and near by town where groundwater is used for domestic and agriculture purposes is discussed.


Water ◽  
2018 ◽  
Vol 10 (8) ◽  
pp. 1037 ◽  
Author(s):  
Jesús Prieto-Amparán ◽  
Beatriz Rocha-Gutiérrez ◽  
María Ballinas-Casarrubias ◽  
María Valles-Aragón ◽  
María Peralta-Pérez ◽  
...  

Water quality is relevant due to the complexity of the interaction of physicochemical and biological parameters. The Irrigation District 005 (ID005) is one of the most important agricultural region in Chihuahua, México; for that reason, it was proposed to investigate the water quality of the site. Water samples were collected in two periods: Summer (S1) and Fall (S2). The samples were taken from 65 wells in S1, and 54 wells in S2. Physicochemical parameters (PhP) such as Arsenic (As), Temperature, Electrical Conductivity (EC), Oxide Reduction Potential (ORP), Hardness, pH, Total Dissolved Solids (TDS), and Turbidity were analyzed. The data were subjected to statistical principal component analysis (PCA), cluster analysis (CA) and spatial variability tests. In both seasons, the TDS exceeded the Mexican maximum permissible level (MPL) (35% S1, 39% S2). Turbidity exceeded the MPL in S1 (29%) and in S2 (12%). Arsenic was above the MPL for water of agricultural use in 9% (S1) and 13% (S2) of the wells. The PCA results suggested that most variations in water quality in S1 were due to As, pH and Temperature, followed by EC, TDS and Hardness; while in S2 to EC, TDS and Hardness, followed by As and pH.


Author(s):  
EUKENE OPORTO BENSIG ◽  
MARY JOYCE L. FLORES ◽  
FLEURDELIZ F. MAGLANGIT

The use of surface waters such as rivers for domestic, agricultural andindustrial purposes have made them vulnerable to pollution leading to impairedwater quality. The water quality of Lahug River in Cebu City was evaluated usingcoliforms as indicators, in relation with physicochemical parameters such as biological oxygen demand (BOD), conductivity, dissolved oxygen (DO), nitrate,pH, phosphate, salinity, temperature, total dissolved solids (TDS) and totalsuspended solids (TSS). Sampling was done once a month from November 2011to April 2012 in three stations covering the upstream, midstream and downstream.The multiple tube fermentation technique was used for the analysis of coliforms.The level of these indicator bacteria increased from the upstream towards thelower reaches of the river especially in the months of February to April; however,the difference in values across time was not significant. This implies that therewas a continuous fecal pollution in the river. There were no statistically significantcorrelations between FCs and TCs with the physicochemical parameters. Anegative relationship was observed among FCs and TCs with pH, TSS, DOand nitrate (p>0.05). These results suggest the presence of sewage and organicpollutants in the river.Keywords: Aquatic Ecology, water quality, coliform, physicochemical parameters,experimental design, Philippines


2015 ◽  
Vol 6 (1) ◽  
pp. 117-121 ◽  
Author(s):  
D Hossain ◽  
MS Islam ◽  
N Sultana ◽  
TR Tusher

The study was conducted to investigate the iron (Fe) contamination in groundwater at Tangail municipality during the period from January to June 2011. Groundwater samples were collected from 18 locations, where 15 were tube-wells, 2 deep tube-wells and 1 pump. The result of the study showed that the highest level of Fe (24.50 mg/l) was found at Dewla north, while the lowest level (1.03 mg/l) was recorded from Bepari para. The highest and lowest amount of Fe was found in ward 1 and 4, respectively. The results were compared with the Bangladesh drinking water quality standards as well as with the international standards. In Bangladesh, permissible limit of Fe is 0.3-1.0 mg/l, whereas WHO standard level is 0.3 mg/l. All the samples were exceeded the standard levels of Fe, whereas ward 1, 2 and 7 were worstly affected. The study also reveal that the availability of Fe does not depend on the type of water sources, but it depends on the aquifers or water table. If the aquifer contains Fe, then the tube-well water will contain Fe or vice versa. These higher Fe concentrations found in the study area may be harmful for those families who are consuming the water from these sources on regular basis. Thus, to overcome this problem the consumers should not drink these higher amounts of Fe, and they should find other sources or replace the tube-well or treat the water before drinking and other domestic and household purposes.DOI: http://dx.doi.org/10.3329/jesnr.v6i1.22051 J. Environ. Sci. & Natural Resources, 6(1): 117-121 2013


2020 ◽  
Vol 1 (1) ◽  
pp. 75-82
Author(s):  
Yustani Leluno ◽  
Kembarawati ◽  
Basuki

The lack of clean water distribution by local water service (PDAM) of Palangka Raya city is the major reason for people around the final processing site/landfill (Tempat Pemrosesan Akhir) at Km 14 to use groundwater for their daily life. The landfill may cause pollution over groundwater known as leachate, which commonly unnoticed by its users. This study aims at assessing the quality of groundwater in that area. The groundwater was taken at different distances from the site in three rainless-days. The physical, chemical and biology parameters of groundwater are observed in the field (in situ) and analyzed in the laboratory, refers to water quality standard of Class I, according to Government Regulation No. 82 of 2001 and Minister of Health Regulation No. 32 of 2017. Public opinion on that issue is cached through interview. The results showed that the groundwater around the landfill in three rainless-days was harmless to be consumed as drinking water, and did not exceed the water quality standards stipulated by government in term of odorless, tasteless, and colorless. Some indicators also show that the groundwater meets the specified quality standards, i.e. TDS (17-68.14 mg/L), DHL (17,15-69.39 ?s), turbidity (0.11-2.50 mg/L), iron (0.227-0.71 mg/L), manganese (<0.0123-0.02 mg/L), coliform (<1.8-280 MPN/100 ml), while Pb and H2S were not detected. From community side, there are no any health complaints arise as long as they use the water.


Sign in / Sign up

Export Citation Format

Share Document