scholarly journals Compressive Behavior and Mechanical Characteristics and Their Application to Stress-Strain Relationship of Steel Fiber-Reinforced Reactive Powder Concrete

2016 ◽  
Vol 2016 ◽  
pp. 1-11 ◽  
Author(s):  
Baek-Il Bae ◽  
Hyun-Ki Choi ◽  
Bong-Seop Lee ◽  
Chang-Hoon Bang

Although mechanical properties of concrete under uniaxial compression are important to design concrete structure, current design codes or other empirical equations have clear limitation on the prediction of mechanical properties. Various types of fiber-reinforced reactive powder concrete matrix were tested for making more usable and accurate estimation equations for mechanical properties for ultra high strength concrete. Investigated matrix has compressive strength ranged from 30 MPa to 200 MPa. Ultra high strength concrete was made by means of reactive powder concrete. Preventing brittle failure of this type of matrix, steel fibers were used. The volume fraction of steel fiber ranged from 0 to 2%. From the test results, steel fibers significantly increase the ductility, strength and stiffness of ultra high strength matrix. They are quantified with previously conducted researches about material properties of concrete under uniaxial loading. Applicability of estimation equations for mechanical properties of concrete was evaluated with test results of this study. From the evaluation, regression analysis was carried out, and new estimation equations were proposed. And these proposed equations were applied into stress-strain relation which was developed by previous research. Ascending part, which was affected by proposed equations of this study directly, well fitted into experimental results.

2018 ◽  
Vol 199 ◽  
pp. 11005 ◽  
Author(s):  
Wasim Abbass ◽  
M. Iqbal Khan

The high strength concrete exhibits improved compressive strength with drawback of brittle failure due to lack of tensile strength which can be catered by the addition of fibers. The efficient use of fibers with hybridization at macro and micro level can improve mechanical properties of high strength concrete. The effect of hybridization of hooked end steel macro fibers (60 mm) and PVA micro fibers (12 mm) with different dosages was investigated in this research work. The different percentage of steel and PVA were hybridized to find out the best combination of hybridized fibers in high strength concrete. The compressive and flexural properties of high strength concrete along with complete load vs deflection behaviour of hybrid fiber reinforced concrete were investigated. The results revealed that hybridization of macro and micro fibers provided better improvement in flexural performance. It was observed from the results that the hybrid combination of fibers of 1% macro steel fiber and 0.15% micro PVA fibers proved to be the best for enhancement in flexural performance of high strength concrete.


2012 ◽  
Vol 174-177 ◽  
pp. 1090-1095 ◽  
Author(s):  
Kai Pei Tian ◽  
Yang Ju ◽  
Hong Bin Liu ◽  
Jin Hui Liu ◽  
Li Wang ◽  
...  

The explosive spalling of high-strength concrete due to fire is a problem that has garnered increasingly widespread attention, particularly the explosive spalling of reactive powder concrete (RPC). For years, based on the vapor pressure mechanism, the addition of fibers has been demonstrated to be somewhat effective in protecting against spalling. However, relevant experiments indicate that fibers are not effective for dense concrete, which is a challenge for the simple vapor pressure mechanism in providing spalling resistance for RPC. The authors found that silica fume plays an important role in the explosive spalling of RPC. Thus, four classes of RPCs with different ratios of silica fume were prepared, and the spalling phenomena and the inner temperature distribution during heating were investigated. The results show that silica fume content has a prominent effect on the spalling process of RPC.


2010 ◽  
Vol 34-35 ◽  
pp. 1441-1444 ◽  
Author(s):  
Ju Zhang ◽  
Chang Wang Yan ◽  
Jin Qing Jia

This paper investigates the compressive strength and splitting tensile strength of ultra high strength concrete containing steel fiber. The steel fibers were added at the volume fractions of 0%, 0.5%, 0.75%, 1.0% and 1.5%. The compressive strength of the steel fiber reinforced ultra high strength concrete (SFRC) reached a maximum at 0.75% volume fraction, being a 15.5% improvement over the UHSC. The splitting tensile strength of the SFRC improved with increasing the volume fraction, achieving 91.9% improvements at 1.5% volume fraction. Strength models were established to predict the compressive and splitting tensile strengths of the SFRC. The models give predictions matching the measurements. Conclusions can be drawn that the marked brittleness with low tensile strength and strain capacities of ultra high strength concrete (UHSC) can be overcome by the addition of steel fibers.


2019 ◽  
Vol 4 (6) ◽  
pp. 74-83 ◽  
Author(s):  
Gamal I. K. ◽  
K. M. Elsayed ◽  
Mohamed Hussein Makhlouf ◽  
M. Alaa

Reactive Powder Concrete RPC is comprise of (cement, quartz powder, sand, and superplasticizer) mixture with low water/cement ratio. It has not coarse aggregates and characterized by highly dense matrix, high strength concrete, excellent durability, and economic. This study aims to investigate fresh and hardened properties of locally cast RPC with several available economical materials such as silica fume (SF), fly ash (FA), steel fiber (STF), and glass fiber (GF). Experimental investigation were performed to study the effectiveness of partial replacement of cement by SF or FA to reach ultra-high strength concrete, effect of additional materials STF or GF in order to improve the fracture properties of the RPC mixes, and influence of the treated with normal water as well as with hot water. Fifteen different RPC mixes were cast with 20, 25, 30, and 35% cement replacement by SF, 25% cement replacement by FA, and another proportions taken combination between SF and FA with percentages 15, 20, 25% FA and constant 10% SF. Varying fiber types (steel fiber or glass fiber) added to concrete by different percentages 1, 2, and 3%. Specimens were treated with normal water 25ᵒC and hot water at 60ᵒC and 90ᵒC by 2 mixes with silica fume content 25% of binder and steel fiber content 2% by total volume. Performance of the various mixes is tested by the slump flow, compressive strength, flexure strength, splitting tensile strength, and density. The production of RPC using local materials is successfully get compressive strength of 121 MPa at the age of 28 days at standard conditions and normal water curing 25°C with Silica fume content 25% of binder and steel fiber content 2% by total volume of RPC and water/binder ratio of 0.25.  The results also showed the effect of curing by hot water 60 and 90°C, it is observed that compressive strength increases proportionally with curing temperatures and a compressive strength of 149.1 MPa at 90°C for 1days was obtained.


Author(s):  
Afzal Basha Syed ◽  
Jayarami Reddy B ◽  
Sashidhar C

In present era, high-strength concrete is progressively utilized in modern concrete technology and particularly in the construction of elevated structures. This examination has been directed to explore the properties of high-strength concrete that was delivered by using stone powder (SP) as an option of extent on sand after being processed. The aim of the research is to study the effect of replacement of sand with stone powder and substitution of cement with mineral admixtures (GGBS & Zeolite) on the mechanical properties of high strength concrete. The test results showed clear improvement in compression and split tensile nature of concrete by using stone powder and mineral admixtures together in concrete. The increment in the magnitude of compressive strength and split tensile strength are comparable with conventional concrete.


The main aim of this work was to investigate the influence of widely used steel fibers and polypropylene fibers on the concrete. From many studies it has been shown that, addition of fibers to the concrete has influenced the cracking of concrete, due to shrinkage, thermal insulation and bleeding of water. So, in this study we made use of ultra high strength concrete mix of M50, and we made use of both steel as well as polypropylene fibers to enhance the properties of the concrete. In this study total five concrete mixes were made with steel fiber in dosages of 2.5%, 2%, 1.5%, 1% and polypropylene fibers are in dosage 0%, 0.5%, 1%, 1.5% of the weight of concrete mix. The specimens were casted and all the specimens are tested for 7days and 28 days strength. The results have depicted a gradual increase in the strength of the concrete as the fiber content increased


Materials ◽  
2019 ◽  
Vol 12 (11) ◽  
pp. 1751 ◽  
Author(s):  
Guangyao Yang ◽  
Jiangxiong Wei ◽  
Qijun Yu ◽  
Haoliang Huang ◽  
Fangxian Li

This study investigated the strength and toughness of reactive powder concrete (RPC) made with various steel fiber lengths and concrete strengths. The results indicated that among RPC samples with strength of 150 MPa, RPC reinforced with long steel fibers had the highest compressive strength, peak strength, and toughness. Among the RPC samples with strength of 270 MPa, RPC reinforced with short steel fibers had the highest compressive strength, and peak strength, while RPC reinforced with medium-length steel fibers had the highest toughness. As a result of the higher bond adhesion between fibers and ultra-high-strength RPC matrix, long steel fibers were more effective for the reinforcement of RPC with strength of 150 MPa, while short steel fibers were more effective for the reinforcement of RPC with strength of 270 MPa.


2018 ◽  
Vol 199 ◽  
pp. 11006
Author(s):  
M. Iqbal Khan ◽  
Wasim Abbass

The hybridization of fibers for arresting the crack in concrete is a key factor and play an important role to improve mechanical properties of high performance concrete with respect to mono fibers. The effect of hybridization of hooked end steel fibers with different length and diameter on mechanical properties of high strength concrete was investigated in this research work. The different percentages of hook ended fibers (60 mm and 40 mm) are hybridized in the concrete mixture while keeping total percentage of fibers by volume equal to 1%. The compressive and flexural properties with complete load verses deflection curves of hybrid steel fiber reinforced high performance concrete were investigated to find the optimized dosage of hybrid steel fibers. The results showed that the hybridization of fiber provided better compressive and flexural performance. It was also observed from the results that combination of 65% of 60 mm and 35% of 40 mm hooked end fibers proved to be best for enhancement in compressive and flexural properties.


Sign in / Sign up

Export Citation Format

Share Document