scholarly journals Diagnostic, Prognostic, Predictive, and Monitoring Role of Neutrophil CD11b and Monocyte CD14 in Neonatal Sepsis

2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Heba E. Hashem ◽  
Zakaria H. Ibrahim ◽  
Wafaa O. Ahmed

Background. Sepsis is a critical medical condition that requires additional diagnostic considerations. Recently, focus has shifted to the diagnosis of sepsis using new markers to overcome the limitations of traditional laboratory diagnostic modalities. Neutrophil CD11b (nCD11b) and monocyteCD14 (mCD14) cell surface antigens have been shown to be useful in such diagnostic consideration. Aim. To investigate the diagnostic, monitoring, prognostic, and predictive roles of nCD11b and mCD14 as sepsis biomarkers in comparison to each other and to traditional laboratory sepsis parameters in order to select the best fit for routine daily use in neonatal intensive care units (NICUs). Subject. The study included 188 neonates from Ain Shams University Hospitals’ NICUs, who were divided into two groups: the control group ( n = 100 ) and the sepsis group ( n = 88 ). Highly sensitive CRP (hs-CRP), complete blood count (CBC), blood culture, and nCD11b and mCD14 evaluations were all part of the laboratory sepsis evaluation (done by flow cytometry technology). Positive blood culture results (BACT/ALERT system) confirmed the sepsis diagnosis. Twenty-four enrolled sepsis neonates were subjected to follow-up assessments, and they were divided into two groups based on clinical improvement: improved sepsis and sepsis without improvement. In order to predict performance evaluation, the subjected neonates were reclassified according to their outcome into survivors’ and nonsurvivors’ group. Results. Sepsis patients had a significant increase in mCD14 MFI values when compared to controls. With sensitivity 75.4 percent, specificity 71.9 percent, efficacy 73.3 percent, and AUC 0.703, mCD14 MFI at cutoff 9.36 could distinguish the presence of septicemia. Significant increases in both mCD14 MFI and nCD11b MFI ( P = 0.001 ) were observed in the severe sepsis/septic shock group compared to the nonsevere sepsis group. The combined measurement of CD14 MFI at cutoff 9.97 and CD14 percent at cutoff 44.7 percent yielded the best predictive performance. Conclusion. Sepsis patients had a significant increase in mCD14 MFI comparable to the controls. mCD14 MFI demonstrated better diagnostic, prognostic, and predictive results than nCD11b. hs-CRP outperformed mCD14 and nCD11b in terms of diagnostic efficacy and AUC. In the monitoring of sepsis patients, both mCD14 and nCD11b produced unsatisfactory results. Currently, the routine use of mCD14 or nCD11b as sepsis biomarkers in neonatal ICUs is not justified.

2020 ◽  
Vol 2020 ◽  
pp. 1-12
Author(s):  
Heba E. Hashem ◽  
Sherin A. El Masry ◽  
Amira M. Mokhtar ◽  
Eman A. Ismail ◽  
Noureldin M. Abdelaal

Background. Neonatal sepsis (NS) is a very critical medical situation associated with high morbidities and mortalities. There is an utmost need for a new tool helping in early diagnosis and proper management of sepsis neonates. Neutrophil CD64 (nCD64) shows a very promising value in this concerning issue. Aim. Evaluate the diagnostic, monitoring, and prognostic performances of nCD64 and highly sensitive CRP (hs-CRP) in NS as well as the possible best panel of biomarkers that can achieve the most desirable results. Methods. Patients were enrolled from three neonatal intensive care units (NICUs) (n=121 patients) and classified according to their initial sepsis evaluation into three groups: disease control group (n=30), proven sepsis group (n=17), and clinical sepsis group (n=74). Laboratory evaluation included hs-CRP, complete blood count (CBC), and blood culture in addition to nCD64 (done by flow cytometry technique). Besides the diagnostic evaluations, follow-up evaluations were done for 40 patients after five days from the first time; patients were reclassified according to their outcome into the improved sepsis neonates’ group (n=26) and sepsis neonates without improvement (n=14). Results. Significant increase in nCD64 and hs-CRP results were present in sepsis groups compared to the disease controls (P<0.001); nCD64 at 43% cutoff value could detect the presence of sepsis with 85.6% sensitivity and 93% specificity. Additionally, delta change percentage (dC%) between improved sepsis neonates and sepsis neonates without improvement showed a significant difference in the levels of both nCD64 (P<0.001) and hs-CRP (P=0.001). Conclusion. Besides the promising diagnostic performance documented by nCD64 which is higher than the other laboratory sepsis biomarkers used routinely in NICUs, nCD64 has a valuable role in sepsis patients’ monitoring and prognostic evaluation. hs-CRP was moderate in its diagnostic and monitoring results being less than that achieved by nCD64. Combined measurement of nCD64% and hs-CRP gives better diagnostic and monitoring performance than that achieved by any of them alone.


2021 ◽  
Author(s):  
Chuchu Gao ◽  
Zongtai Feng ◽  
Lixia Wang ◽  
Xingxing Zhao ◽  
Kai Fu ◽  
...  

Abstract Background: Neonatal sepsis is a systemic inflammatory response syndrome in neonates. The molecular mechanism of neonatal sepsis remains incompletely clarified. The purpose of this study was to explore the potential value of receptor interacting protein 3 (RIP3) in neonatal sepsis.Methods: 93 neonates with sepsis and 93 neonates without infectious diseases were enrolled in this study from September 2019 to March 2021. Plasma RIP3 was detected by enzyme-linked immunosorbent assay (ELISA) and assessed along with whole blood hypersensitive C-reactive protein (hs-CRP) and platelet count (PLT). Differences of RIP3, hs-CRP and PLT between the two groups were compared. Changes of the three indicators in sepsis were also observed after treatment. The diagnostic value of indicators for neonatal sepsis was evaluated by receiver operating characteristic (ROC) curve.Results: In sepsis group, RIP3 and hs-CRP levels were significantly higher than those in control group (RIP3, p < 0.0001; hs-CRP, p < 0.0001), and PLT level was significantly lower than that in control group (p<0.0001). After treatment, RIP3 and hs-CRP levels among septic survivors had a significant decrease (p<0.0001) and PLT level had a significant improvement (p=0.0028). With RIP3>15464.72 pg/mL, CRP>3.24 mg/L, PLT<205.00×109 /L as the positive criteria, the sensitivity of the three indicators in the diagnosis of neonatal sepsis was 68.8%, 64.5%, 59.1%, and the specificity was 91.4%, 82.8%, 79.6%, respectively. The combination of RIP3, CRP and PLT showed 76.3% sensitivity and 94.6% sensitivity.Conclusions: RIP3 may attribute to the early diagnosis and understanding therapeutic effect of neonatal sepsis. The combined detection of RIP3, CRP and PLT may be more effective than individual ones in the diagnosis of neonatal sepsis.


2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Heba E. Hashem ◽  
Rania M. Abdel Halim ◽  
Sherin A. El Masry ◽  
Amira M. Mokhtar ◽  
Noureldin M. Abdelaal

Background. Neonatal septicemia is a critical medical situation; current conventional laboratory methods still have many limitations and diagnostic obstacles. For this purpose, last decades have witnessed a challenge between the battery of sepsis biomarkers including many leukocyte surface antigens, not only for early diagnostic purposes but also for better follow-up and good management of sepsis patients. Aim. To evaluate the diagnostic, prognostic, and monitoring performance of both neutrophil CD64 (nCD64) and presepsin as sepsis biomarkers compared to each other and to the conventional laboratory sepsis parameters aiming to decide which is the best fitting for routine daily use in neonatal intensive care units (NICUs). Methods. 235 neonates were enrolled from three Egyptian neonatal ICUs, during the period from November 2015 till March 2018; they were classified into two main groups: the control group (n = 102) and the sepsis group (n = 133). Laboratory sepsis evaluation included highly sensitive CRP (hs-CRP), CBC, in addition to nCD64 (flow cytometry technique), and presepsin measurement (CLEIA technique combined with Magtration® technology); the diagnosis was confirmed thereafter by positive blood culture results (BacT/Alert system). Sixty-two of the enrolled sepsis neonates were subjected to follow-up assessment; they were reclassified according to their clinical improvement at the second time assessment into (group 1: sepsis group without improvement) (n = 20) and (group 2: improved sepsis group) (n = 42). Results. Significant increase in nCD64 and presepsin values was found in sepsis groups compared to the controls. At cutoff 41.6%, nCD64% could discriminate the presence of septicemia with sensitivity 94.7%, specificity 93.6 %, and AUC 0.925, while presepsin at cutoff 686 pg/ml achieves sensitivity 82.7%, specificity 95.5%, and AUC 0.887, respectively. Significant increase in nCD64 ( P < 0.001 ) and hs-CRP ( P = 0.018 ) values was observed in severe sepsis/septic shock patients compared to nonsevere sepsis patients. Delta change percentage (dC%) between initial and follow-up evaluations for both improved and nonimproved sepsis patients was dC Z value −5.904 for nCD64% followed by dC Z value −4.494 for presepsin. Conclusion. nCD64 and presepsin are valuable early diagnostic and monitoring sepsis biomarkers; the highest sensitivity could be achieved by a univariant sepsis marker in this study was recorded by the nCD64% biomarker, while the highest specificity was documented by presepsin. Combined measurement of both achieves the highest diagnostic performance in sepsis neonates. Either of CD64 or presepsin combined with hs-CRP associated with better performance than any of them alone. nCD64 carries an additional promising role in reflecting sepsis prognosis.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Chuchu Gao ◽  
Zongtai Feng ◽  
Lixia Wang ◽  
Xingxing Zhao ◽  
Kai Fu ◽  
...  

Abstract Background Late-onset sepsis (LOS) is a systemic inflammatory response syndrome in neonates, and the molecular mechanism of LOS is incompletely characterized. The purpose of this study was to explore the potential value of receptor interacting protein 3 (RIP3) in LOS. Methods 63 neonates with LOS supported by positive culture and 79 neonates without sepsis were enrolled in this study from September 2019 to March 2021. Plasma RIP3 was detected by enzyme-linked immunosorbent assay (ELISA) and assessed along with the whole blood hypersensitive C-reactive protein (hs-CRP) level and platelet count (PLT). Differences in RIP3, hs-CRP and PLT between the two groups were compared. Changes in the three indicators in sepsis were also observed after treatment. The diagnostic value of indicators for LOS was evaluated by receiver operating characteristic (ROC) curve analysis. Results In the sepsis group, RIP3 and hs-CRP levels were significantly higher than those in the control group (RIP3, p < 0.0001; hs-CRP, p < 0.0001), and PLT was significantly lower than that in the control group (p < 0.0001). After treatment, RIP3 and hs-CRP levels among septic survivors were significantly decreased (p < 0.0001) and PLT significantly improved (p = 0.0216). With RIP3 > 15,845.19 pg/mL, hs-CRP > 5.00 mg/L, and PLT < 204.00 × 109/L as the positive criteria, the sensitivity values of the three indicators in the diagnosis of LOS were 69.8%, 60.3%, 60.3%, respectively, and the specificity values were 92.4%, 96.2%, 79.8%, respectively. The combination of RIP3, hs-CRP and PLT had a sensitivity of 77.8% and specificity of 97.5%. Conclusions RIP3 may contribute to the early diagnosis of LOS and monitoring of treatment effect. The combined detection of RIP3, hs-CRP and PLT may be more effective than individual detection in the diagnosis of LOS.


2020 ◽  
Vol 17 (7) ◽  
pp. 3113-3116
Author(s):  
Dyah Anetta Afri Rukmi ◽  
Joseph Eko Wahono Rahardjo

C-Reactive Protein is a marker of inflammation and vascular disease. The high serum of high-sensitivity C-Reactive Protein (hs-CRP) concentration was associated with interruption the integrity of the frontal-subcortical circuit. To determine the correlation between high serum concentration of hs-CRP and executive function disorder in elderly patients. Thirty six elderly patients was examined by using a case control study. The subjects were enrolled from the out-patient at Neurology Department Dr. Soetomo General Hospital, Surabaya, Indonesia. The time period was 4 months (April to July 2015). Executive function was measured with the Trail Making Test B (TMT B) and divided into two groups, case and control. Complete blood count and serum hs-CRP concentration were measured from nonfasting blood samples. Chi-square test was used for data analysis. Eighteen subjects were enrolled in the case group (3 men, 15 women) and the other 18 subjects were enrolled in the control group (4 men, 14 women). Executive function disorder was found in 17 (94,4%) subjects of case group and 11 (61,1%) subjects of control group. High levels of hs-CRP was not associated with executive function, with p = 0,149 and adjusted OR 5,629 (CI 95% 0, 538-58, 860). These data suggested that high levels of hs-CRP was not associated with executive function in elderly patients.


2020 ◽  
Vol 58 (11) ◽  
pp. 1951-1957 ◽  
Author(s):  
Luisa Agnello ◽  
Giulia Bivona ◽  
Matteo Vidali ◽  
Concetta Scazzone ◽  
Rosaria Vincenza Giglio ◽  
...  

AbstractObjectivesThe diagnosis of sepsis in the Emergency Department (ED) is challenging and a reliable biomarker is needed. The current study aimed to evaluate the diagnostic accuracy of monocyte distribution width (MDW) for the early identification of sepsis in the ED.MethodsWe performed a large observational study including consecutive adult patients (≥18 years of age) presenting to the ED between September and November 2019, with an order for complete blood count (CBC) evaluation. A total of 2,215 patients were enrolled and classified based on Sepsis-2 criteria as the control group (1,855), infection group (172), Systemic Inflammatory Response Syndrome (SIRS) group (100), and sepsis group (88).ResultsMDW levels were higher in patients with sepsis than in all other groups (p<0.001). ROC curve analysis showed an optimal diagnostic accuracy of MDW for sepsis prediction at a cut-off point of 23.5, with an AUC of 0.964, sensitivity and specificity of 0.920 and 0.929, respectively.ConclusionsOur findings encourage further investigation to validate the use of MDW as a screening tool for the early identification of patients at risk of sepsis in the ED.


2019 ◽  
Vol 20 (10) ◽  
pp. 781-784 ◽  
Author(s):  
Meizhen Zhao ◽  
Li Juanjuan ◽  
Fan Weijia ◽  
Xie Jing ◽  
Huang Qiuhua ◽  
...  

Background: This study aimed to investigate the expression levels of microRNA (miRNA)-125b in serum exosomes and its diagnostic efficacy for asthma severity. Methods: The study included 80 patients with untreated asthma and 80 healthy volunteers. The patients were divided into 4 groups according to disease severity: 20 with the intermittent state, 20 with the mildly persistent state, 20 with the moderately persistent state, and 20 with the severely persistent state. The expression levels of miRNA-125b in serum exosomes of each group were detected using a quantitative polymerase chain reaction and compared. The Spearman correlation analysis was used to study the correlation between the expression levels of miRNA-125b in serum exosomes and asthma severity. The diagnostic efficacy of the expression levels of miRNA-125b in exosomes for asthma severity was evaluated using the Receiver Operating Characteristic (ROC) curve. Results: The expression levels of miRNA-125b in serum exosomes of patients with intermittent, mildly persistent, moderately persistent, and severely persistent asthma were all higher than those in the healthy control group, with statistically significant differences. The expression levels of miRNA-125b were also statistically significantly different among patients in each group. The Spearman correlation analysis showed a positive correlation of the relative expression of miRNA-125b in serum exosomes with asthma severity. The area under the ROC curve of the diagnostic efficacy of miRNA-125b in serum exosomes for patients with intermittent, mildly, moderately, and severely persistent asthma was 0.7770, 0.8573, 0.9111, and 0.9995, respectively. Conclusion: The expression levels of miRNA-125b in serum exosomes had a high diagnostic efficacy and might serve as a noninvasive diagnostic marker for asthma severity.


OTO Open ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 2473974X2198959
Author(s):  
Ahmed Yassin Bahgat

Objective Plasma is formed by creating a high-density energy field within an electrically conductive fluid such as saline. Sometimes ablated bits of tissue get stuck between the electrodes of the wand, obstructing the suction channel. The purpose of this study is to investigate the effect of cooling the irrigating saline during ablation of the hypertrophied tongue base in patients with obstructive sleep apnea. Study Design Prospective randomized controlled trial. Setting An otorhinolaryngology department in Main University hospitals. Methods Sixty adult patients with obstructive sleep apnea and tongue base hypertrophy underwent tongue base ablation surgery. Patients were randomly divided into 2 groups of 30 patients each: cooled saline and room temperature saline. The Coblation wand used was the EVac 70 Xtra HP (Smith & Nephew). Results In this study, a significant difference in operative time (mean ± SD) was seen between groups: 21.2 ± 5.5 minutes in the cold group and 47 ± 9.5 minutes in the control group ( P = .001). The wands in the cold group did not obstruct, while all the wands in the control group were obstructed by tissue clogs with variable degrees, hence wasting more time to clean the wands’ tips. Conclusion Cooling the irrigating saline overcame the problem of wand clogs, and the wand tip did not occlude at all during the procedures, thus saving time lost in wand cleaning and demonstrating a faster and safer surgical procedure. Further studies are needed to identify the hemostatic effect of the cooled saline over the regular one.


2021 ◽  
pp. 014556132098603
Author(s):  
Anni Koskinen ◽  
Marie Lundberg ◽  
Markus Lilja ◽  
Jyri Myller ◽  
Matti Penttilä ◽  
...  

Objectives: The aim of this controlled follow-up study was to compare the need for revision surgery, long-term efficacy, and satisfaction in chronic rhinosinusitis patients who had undergone maxillary sinus operation with either balloon sinuplasty or traditional endoscopic sinus surgery (ESS) technique. Methods: Thirty-nine ESS patients and 36 balloon patients of our previously described cohort, who had been primarily operated in 2008 to 2010, were contacted by phone. Symptoms, satisfaction, and need for revision surgery were asked. In addition, we collected data of patients who had undergone primary maxillary sinus balloon sinuplasty in the Helsinki University Hospital during the years 2005 to 2019. As a control group, we collected data of patients who had undergone primary maxillary sinus ESS at 3 Finnish University Hospitals, and 1 Central Hospital in years 2005, 2008, and 2011. Results: Altogether, 77 balloon patients and 82 ESS patients were included. The mean follow-up time was 5.3 years in balloon group and 9.8 years in ESS group. Revision surgery was performed on 17 balloon patients and 6 ESS patients. In the survival analysis, the balloon sinuplasty associated significantly with a higher risk of revision surgery compared to ESS. According to the phone interviews, 82% of ESS patients and 75% of balloon patients were very satisfied with the primary operation. Conclusion: Although the patient groups expressed equal satisfaction and change in symptoms after the operations, the need for revision surgery was higher after balloon sinuplasty than after ESS. This should be emphasized when counselling patients regarding surgical options.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Esin Merve Erol Koç ◽  
Rahime Bedir Fındık ◽  
Hatice Akkaya ◽  
Işılay Karadağ ◽  
Eda Özden Tokalıoğlu ◽  
...  

AbstractObjectivesTo evaluate the relationship between Coronavirus Disease 2019 (COVID-19) in pregnancy and adverse perinatal outcomes. The secondary aim is to analyze the diagnostic value of hematologic parameters in COVID-19 complicated pregnancies.MethodsThe current study is conducted in a high volume tertiary obstetrics center burdened by COVID-19 pandemics, in Turkey. In this cohort study, perinatal outcomes and complete blood count indices performed at the time of admission of 39 pregnancies (Study group) complicated by COVID-19 were compared with 69 uncomplicated pregnancies (Control group).ResultsThere was no significant difference between the obstetric and neonatal outcomes of pregnancies with COVID-19 compared to data of healthy pregnancies, except the increased C-section rate (p=0.026). Monocyte count, red cell distribution width (RDW), neutrophil/lymphocyte ratio (NLR), and monocyte/lymphocyte ratio (MLR) were significantly increased (p<0.0001, p=0.009, p=0.043, p<0.0001, respectively) whereas the MPV and plateletcrit were significantly decreased (p=0.001, p=0.008) in pregnants with COVID-19. ROC analysis revealed that the optimal cut-off value for MLR was 0.354 which indicated 96.7% specificity and 59.5% sensitivity in diagnosis of pregnant women with COVID-19. A strong positive correlation was found between the MLR and the presence of cough symptom (r=41.4, p=<0.0001).ConclusionsThe study revealed that, pregnancies complicated by COVID-19 is not related with adverse perinatal outcomes. MLR may serve as a supportive diagnostic parameter together with the Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) in assessment of COVID-19 in pregnant cohort.


Sign in / Sign up

Export Citation Format

Share Document