scholarly journals Quantifying the Imprint of a Severe Hector Thunderstorm during ACTIVE/SCOUT-O3 onto the Water Content in the Upper Troposphere/Lower Stratosphere

2009 ◽  
Vol 137 (8) ◽  
pp. 2493-2514 ◽  
Author(s):  
Charles Chemel ◽  
Maria R. Russo ◽  
John A. Pyle ◽  
Ranjeet S. Sokhi ◽  
Cornelius Schiller

Abstract The development of a severe Hector thunderstorm that formed over the Tiwi Islands, north of Australia, during the Aerosol and Chemical Transport in Tropical Convection/Stratospheric-Climate Links with Emphasis on the Upper Troposphere and Lower Stratosphere (ACTIVE/SCOUT-O3) field campaign in late 2005, is simulated by the Advanced Research Weather Research and Forecasting (ARW) model and the Met Office Unified Model (UM). The general aim of this paper is to investigate the role of isolated deep convection over the tropics in regulating the water content in the upper troposphere/lower stratosphere (UT/LS). Using a horizontal resolution as fine as 1 km, the numerical simulations reproduce the timing, structure, and strength of Hector fairly well when compared with field campaign observations. The sensitivity of results from ARW to horizontal resolution is investigated by running the model in a large-eddy simulation mode with a horizontal resolution of 250 m. While refining the horizontal resolution to 250 m leads to a better representation of convection with respect to rainfall, the characteristics of the Hector thunderstorm are basically similar in space and time to those obtained in the 1-km-horizontal-resolution simulations. Several overshooting updrafts penetrating the tropopause are produced in the simulations during the mature stage of Hector. The penetration of rising towering cumulus clouds into the LS maintains the entrainment of air at the interface between the UT and the LS. Vertical exchanges resulting from this entrainment process have a significant impact on the redistribution of atmospheric constituents within the UT/LS region at the scale of the islands. In particular, a large amount of water is injected in the LS. The fate of the ice particles as Hector develops drives the water vapor mixing ratio to saturation by sublimation of the injected ice particles, moistening the air in the LS. The moistening was found to be fairly significant above 380 K and averaged about 0.06 ppmv in the range 380–420 K for ARW. As for UM, the moistening was found to be much larger (about 2.24 ppmv in the range of 380–420 K) than for ARW. This result confirms that convective transport can play an important role in regulating the water vapor mixing ratio in the LS.

2014 ◽  
Vol 14 (19) ◽  
pp. 10803-10822 ◽  
Author(s):  
A. Kunz ◽  
N. Spelten ◽  
P. Konopka ◽  
R. Müller ◽  
R. M. Forbes ◽  
...  

Abstract. An evaluation of water vapor in the upper troposphere and lower stratosphere (UTLS) of the ERA-Interim, the global atmospheric reanalysis produced by the European Centre for Medium-Range Weather Forecasts (ECMWF), is presented. Water vapor measurements are derived from the Fast In situ Stratospheric Hygrometer (FISH) during a large set of airborne measurement campaigns from 2001 to 2011 in the tropics, midlatitudes and polar regions, covering isentropic layers from 300 to 400K (5–18km). The comparison shows around 87% of the reanalysis data are within a factor of 2 of the FISH water vapor measurements and around 30% have a nearly perfect agreement with an over- and underestimation lower than 10%. Nevertheless, strong over- and underestimations can occur both in the UT and LS, in particularly in the extratropical LS and in the tropical UT, where severe over- and underestimations up to 10 times can occur. The analysis data from the evolving ECMWF operational system is also evaluated, and the FISH measurements are divided into time periods representing different cycles of the Integrated Forecast System (IFS). The agreement with FISH improves over the time, in particular when comparing water vapor fields for time periods before 2004 and after 2010. It appears that influences of tropical tropospheric and extratropical UTLS processes, e.g., convective and quasi-isentropic exchange processes, are particularly challenging for the simulation of the UTLS water vapor distribution. Both the reanalysis and operational analysis data show the tendency of an overestimation of low water vapor mixing ratio (⪅10ppmv) in the LS and underestimation of high water vapor mixing ratio (⪆300ppmv) in the UT.


2008 ◽  
Vol 8 (17) ◽  
pp. 5245-5261 ◽  
Author(s):  
C. Kiemle ◽  
M. Wirth ◽  
A. Fix ◽  
G. Ehret ◽  
U. Schumann ◽  
...  

Abstract. In the tropics, deep convection is the major source of uncertainty in water vapor transport to the upper troposphere and into the stratosphere. Although accurate measurements in this region would be of first order importance to better understand the processes that govern stratospheric water vapor concentrations and trends in the context of a changing climate, they are sparse because of instrumental shortcomings and observational challenges. Therefore, the Falcon research aircraft of the Deutsches Zentrum für Luft- und Raumfahrt (DLR) flew a zenith-viewing water vapor differential absorption lidar (DIAL) during the Tropical Convection, Cirrus and Nitrogen Oxides Experiment (TROCCINOX) in 2004 and 2005 in Brazil. The measurements were performed alternatively on three water vapor absorption lines of different strength around 940 nm. These are the first aircraft DIAL measurements in the tropical upper troposphere and in the mid-latitudes lower stratosphere. Sensitivity analyses reveal an accuracy of 5% between altitudes of 8 and 16 km. This is confirmed by intercomparisons with the Fast In-situ Stratospheric Hygrometer (FISH) and the Fluorescent Advanced Stratospheric Hygrometer (FLASH) onboard the Russian M-55 Geophysica research aircraft during five coordinated flights. The average relative differences between FISH and DIAL amount to −3%±8% and between FLASH and DIAL to −8%±14%, negative meaning DIAL is more humid. The average distance between the probed air masses was 129 km. The DIAL is found to have no altitude- or latitude-dependent bias. A comparison with the balloon ascent of a laser absorption spectrometer gives an average difference of 0%±19% at a distance of 75 km. Six tropical DIAL under-flights of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on board ENVISAT reveal a mean difference of −8%±49% at an average distance of 315 km. While the comparison with MIPAS is somewhat less significant due to poorer comparison conditions, the agreement with the in-situ hygrometers provides evidence of the excellent quality of FISH, FLASH and DIAL. Most DIAL profiles exhibit a smooth exponential decrease of water vapor mixing ratio in the tropical upper troposphere to lower stratosphere transition. The hygropause with a minimum mixing ratio of 2.5 µmol/mol is found between 15 and 17 km. A high-resolution (2 km horizontal, 0.2 km vertical) DIAL cross section through the anvil outflow of tropical convection shows that the ambient humidity is increased by a factor of three across 100 km.


2020 ◽  
Author(s):  
Dina Khordakova ◽  
Christian Rolf ◽  
Martina Krämer ◽  
Martin Riese

<p>Water vapor is one of the strongest greenhouse gases of the atmosphere. Its driving role in the upper troposphere / lower stratosphere region (UTLS) for the radiation budget was shown by e.g. Riese et al., (2012). Despite its low abundance of 4 - 6 ppmv in the stratosphere, even small changes in its mixing ratio can leed to a positive feedback to global warming. To better understand changes and variability of water vapor in the lower stratosphere, we focus here on exchange processes from the moist troposphere to the dry stratosphere in the mid latitudes. These processes are caused by extreme vertical convection, which is expected to increase in intensity and frequency with progressive global climate change.</p><p>Within the MOSES (Modular Observation Solutions for Earth Systems) campaign in the summer of 2019, two extreme vertical convection events could be captured with balloon borne humidity sensors over the eastern part of Germany. The comparison of measurements before and after both events reveal distinct water vapor enhancements in the lower stratosphere and show that even in mid-latitudes over shooting convection can impact the water vapor mixing ratio in the UTLS. The measurements are compared with the Microwave Limb Sounder (MLS) data as well as ECMWF reanalysis data.</p><p><span>We will show a deeper analysis of both events by using visible and infrared weather satellite images in combination with meteorological fields of ECMWF. </span><span>B</span><span>ackward trajectories of the air masses </span><span>with the enriched water vapor mixing ratios </span><span>calculated with</span><span> the CLAMS model </span><span>and</span> <span>combined</span><span> with the satellite images can </span><span>confirm the convective origin. </span><span>Additionally,</span><span> we show the </span><span>further </span><span>development of this distinct water vapor filaments within the lower stratosphere </span><span>in order to</span><span> trace the transport and mixing process, </span><span>based on an</span> <span>analysis of forward trajectories.</span></p>


2015 ◽  
Vol 8 (1) ◽  
pp. 211-224 ◽  
Author(s):  
T. D. Thornberry ◽  
A. W. Rollins ◽  
R. S. Gao ◽  
L. A. Watts ◽  
S. J. Ciciora ◽  
...  

Abstract. The recently developed NOAA Water instrument is a two-channel, closed-path, tunable diode laser absorption spectrometer designed for the measurement of upper troposphere/lower stratosphere water vapor and enhanced total water (vapor + inertially enhanced condensed phase) from the NASA Global Hawk unmanned aircraft system (UAS) or other high-altitude research aircraft. The instrument utilizes wavelength-modulated spectroscopy with second harmonic detection near 2694 nm to achieve high precision with a 79 cm double-pass optical path. The detection cells are operated under constant temperature, pressure, and flow conditions to maintain a constant sensitivity to H2O independent of the ambient sampling environment. An onboard calibration system is used to perform periodic in situ calibrations to verify the stability of the instrument sensitivity during flight. For the water vapor channel, ambient air is sampled perpendicular to the flow past the aircraft in order to reject cloud particles, while the total water channel uses a heated, forward-facing inlet to sample both water vapor and cloud particles. The total water inlet operates subisokinetically, thereby inertially enhancing cloud particle number in the sample flow and affording increased cloud water content sensitivity. The NOAA Water instrument was flown for the first time during the second deployment of the Airborne Tropical TRopopause EXperiment (ATTREX) in February–March 2013 on the NASA Global Hawk UAS. The instrument demonstrated a typical in-flight precision (1 s, 1σ) of better than 0.17 parts per million (ppm, 10−6 mol mol−1), with an overall H2O vapor measurement uncertainty of 5% ± 0.23 ppm. The inertial enhancement for cirrus cloud particle sampling under ATTREX flight conditions ranged from 33 to 48 for ice particles larger than 8 μm in diameter, depending primarily on aircraft altitude. The resulting ice water content detection limit (2σ) was 0.023–0.013 ppm, corresponding to approximately 2 μg m−3, with an estimated overall uncertainty of 20%.


2014 ◽  
Vol 7 (8) ◽  
pp. 8271-8309 ◽  
Author(s):  
T. D. Thornberry ◽  
A. W. Rollins ◽  
R. S. Gao ◽  
L. A. Watts ◽  
S. J. Ciciora ◽  
...  

Abstract. The recently developed NOAA Water instrument is a two-channel, closed-path, tunable diode laser absorption spectrometer designed for the measurement of water vapor and enhanced total water (vapor + inertially enhanced condensed-phase) in the upper troposphere/lower stratosphere from the NASA Global Hawk unmanned aircraft system (UAS) or other high-altitude research aircraft. The instrument utilizes wavelength-modulated spectroscopy with second harmonic detection near 2694 nm to achieve high precision with a 79 cm double-pass optical path. The detection cells are operated under constant temperature, pressure and flow conditions to maintain a constant sensitivity to H2O independent of the ambient sampling environment. An on-board calibration system is used to perform periodic in situ calibrations to verify the stability of the instrument sensitivity during flight. For the water vapor channel, ambient air is sampled perpendicular to the flow past the aircraft in order to reject cloud particles, while the total water channel uses a heated, forward-facing inlet to sample both water vapor and cloud particles. The total water inlet operates subisokinetically, thereby inertially enhancing cloud particle number in the sample flow and affording increased cloud water content sensitivity. The NOAA Water instrument was flown for the first time during the second deployment of the Airborne Tropical TRopopause EXperiment (ATTREX) in February–March 2013 on board the Global Hawk UAS. The instrument demonstrated a typical in-flight precision (1 s, 1σ) of better than 0.17 parts per million (ppm, 10−6 mol mol−1), with an overall H2O vapor measurement uncertainty of 5% ± 0.23 ppm. The inertial enhancement for cirrus cloud particle sampling under ATTREX flight conditions ranged from 33–48 for ice particles larger than 8 μm in diameter, depending primarily on aircraft altitude. The resulting ice water content detection limit (2σ) was 0.023–0.013 ppm, corresponding to approximately 2 μg m−3, with an estimated overall uncertainty of 20%.


2008 ◽  
Vol 8 (3) ◽  
pp. 10353-10396 ◽  
Author(s):  
C. Kiemle ◽  
M. Wirth ◽  
A. Fix ◽  
G. Ehret ◽  
U. Schumann ◽  
...  

Abstract. In the tropics, deep convection is the major source of uncertainty in water vapor transport to the upper troposphere and into the stratosphere. Although accurate measurements in this region would be of first order importance to better understand the processes that govern stratospheric water vapor concentrations and trends in the context of a changing climate, they are sparse because of instrumental shortcomings and observational challenges. Therefore, the Falcon research aircraft of the Deutsches Zentrum für Luft- und Raumfahrt (DLR) flew a zenith-viewing water vapor differential absorption lidar (DIAL) during the Tropical Convection, Cirrus and Nitrogen Oxides Experiment (TROCCINOX) in 2004 and 2005 in Brazil. The measurements were performed alternatively on three water vapor absorption lines of different strength around 940 nm. These are the first aircraft DIAL measurements in the tropical upper troposphere and in the mid-latitudes lower stratosphere. A sensitivity analysis reveals that the DIAL profiles have an accuracy of ~5% between altitudes of 8 and 16 km. This is confirmed by intercomparisons with the Fast In-situ Stratospheric Hygrometer (FISH) and the Fluorescent Advanced Stratospheric Hygrometer (FLASH) onboard the Russian M-55 Geophysica research aircraft during five coordinated flights. The average relative differences between FISH and DIAL amount to –3%±8% and between FLASH and DIAL to –8%±14%, negative meaning DIAL is more humid. The average distance between the probed air masses was 129 km. The DIAL is found to have no altitude- or latitude-dependent bias. A comparison with the balloon ascent of a laser absorption spectrometer gives an average difference of 0%±19% at a distance of 75 km. Six tropical DIAL under-flights of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on board ENVISAT show a mean difference of –8%±49% at an average distance of 315 km. While the comparison with MIPAS is somewhat less significant due to poorer comparison conditions, the agreement with the in-situ hygrometers provides evidence of the excellent quality of FISH, FLASH and DIAL. Most DIAL profiles exhibit a smooth exponential decrease of water vapor mixing ratio in the tropical upper troposphere to lower stratosphere transition. The hygropause with a minimum mixing ratio of ~2.5 μmol/mol is found between 15 and 16 km, 1 to 2 km beneath the local tropopause. A high-resolution (2 km horizontal, ~200 m vertical) DIAL cross section through the anvil outflow of tropical convection shows that the ambient humidity is increased by a factor of three across 100 km.


2016 ◽  
Author(s):  
M. Venkat Ratnam ◽  
S. Ravindra Babu ◽  
S. S. Das ◽  
Ghouse Basha ◽  
B. V. Krishnamurthy ◽  
...  

Abstract. Tropical cyclones play an important role in modifying the tropopause structure and dynamics as well as stratosphere-troposphere exchange (STE) process in the Upper Troposphere and Lower Stratosphere (UTLS) region. In the present study, the impact of cyclones that occurred over the North Indian Ocean during 2007–2013 on the STE process is quantified using satellite observations. Tropopause characteristics during cyclones are obtained from the Global Positioning System (GPS) Radio Occultation (RO) measurements and ozone and water vapor concentrations in UTLS region are obtained from Aura-Microwave Limb Sounder (MLS) satellite observations. The effect of cyclones on the tropopause parameters is observed to be more prominent within 500 km from the centre of cyclone. In our earlier study we have observed decrease (increase) in the tropopause altitude (temperature) up to 0.6 km (3 K) and the convective outflow level increased up to 2 km. This change leads to a total increase in the tropical tropopause layer (TTL) thickness of 3 km within the 500 km from the centre of cyclone. Interestingly, an enhancement in the ozone mixing ratio in the upper troposphere is clearly noticed within 500 km from cyclone centre whereas the enhancement in the water vapor in the lower stratosphere is more significant on south-east side extending from 500–1000 km away from the cyclone centre. We estimated the cross-tropopause mass flux for different intensities of cyclones and found that the mean flux from stratosphere to troposphere for cyclonic stroms is 0.05 ± 0.29 × 10−3 kg m−2 and for very severe cyclonic stroms it is 0.5 ± 1.07 × 10−3 kg m−2. More downward flux is noticed in the north-west and south-west side of the cyclone centre. These results indicate that the cyclones have significant impact in effecting the tropopause structure, ozone and water vapour budget and consequentially the STE in the UTLS region.


2019 ◽  
Vol 77 (3) ◽  
pp. 1081-1100 ◽  
Author(s):  
Neil P. Lareau

Abstract Doppler and Raman lidar observations of vertical velocity and water vapor mixing ratio are used to probe the physics and statistics of subcloud and cloud-base latent heat fluxes during cumulus convection at the ARM Southern Great Plains (SGP) site in Oklahoma, United States. The statistical results show that latent heat fluxes increase with height from the surface up to ~0.8Zi (where Zi is the convective boundary layer depth) and then decrease to ~0 at Zi. Peak fluxes aloft exceeding 500 W m−2 are associated with periods of increased cumulus cloud cover and stronger jumps in the mean humidity profile. These entrainment fluxes are much larger than the surface fluxes, indicating substantial drying over the 0–0.8Zi layer accompanied by moistening aloft as the CBL deepens over the diurnal cycle. We also show that the boundary layer humidity budget is approximately closed by computing the flux divergence across the 0–0.8Zi layer. Composite subcloud velocity and water vapor anomalies show that clouds are linked to coherent updraft and moisture plumes. The moisture anomaly is Gaussian, most pronounced above 0.8Zi and systematically wider than the velocity anomaly, which has a narrow central updraft flanked by downdrafts. This size and shape disparity results in downdrafts characterized by a high water vapor mixing ratio and thus a broad joint probability density function (JPDF) of velocity and mixing ratio in the upper CBL. We also show that cloud-base latent heat fluxes can be both positive and negative and that the instantaneous positive fluxes can be very large (~10 000 W m−2). However, since cloud fraction tends to be small, the net impact of these fluxes remains modest.


Sign in / Sign up

Export Citation Format

Share Document