scholarly journals Numerical analyses of the sound transmission at low frequencies of a calibrated domestic wooden window

Author(s):  
Chaima Soussi ◽  
Mathieu Aucejo ◽  
Walid Larbi ◽  
Jean-François Deü

This work focuses on the numerical prediction of the sound transmission of wooden windows in the low frequency range. In this context, the finite element method is used to solve the multiphysics problem. This choice is justified by the fact that this approach is suitable for the resolution of fluid-structure interaction problems in low frequencies, due in particular to its flexibility in taking into account the coupling between domains and the geometrical and material complexities of the structures. To reach the desired objective, experimental modal analyses of the main components of a window, and then of a complete one, are performed in order to calibrate the numerical models. Then, a configuration that combines free-fields on both sides of the structure is employed to evaluate the intrinsic acoustic response of the window. The numerical results for a symmetric and an asymmetric glazing are compared to experimental ones to evaluate the efficiency and validity of the developed models.

Geophysics ◽  
1992 ◽  
Vol 57 (6) ◽  
pp. 854-859 ◽  
Author(s):  
Xiao Ming Tang

A new technique for measuring elastic wave attenuation in the frequency range of 10–150 kHz consists of measuring low‐frequency waveforms using two cylindrical bars of the same material but of different lengths. The attenuation is obtained through two steps. In the first, the waveform measured within the shorter bar is propagated to the length of the longer bar, and the distortion of the waveform due to the dispersion effect of the cylindrical waveguide is compensated. The second step is the inversion for the attenuation or Q of the bar material by minimizing the difference between the waveform propagated from the shorter bar and the waveform measured within the longer bar. The waveform inversion is performed in the time domain, and the waveforms can be appropriately truncated to avoid multiple reflections due to the finite size of the (shorter) sample, allowing attenuation to be measured at long wavelengths or low frequencies. The frequency range in which this technique operates fills the gap between the resonant bar measurement (∼10 kHz) and ultrasonic measurement (∼100–1000 kHz). By using the technique, attenuation values in a PVC (a highly attenuative) material and in Sierra White granite were measured in the frequency range of 40–140 kHz. The obtained attenuation values for the two materials are found to be reliable and consistent.


2007 ◽  
Vol 38 (7) ◽  
pp. 11-17
Author(s):  
Ronald M. Aarts

Conventionally, the ultimate goal in loudspeaker design has been to obtain a flat frequency response over a specified frequency range. This can be achieved by carefully selecting the main loudspeaker parameters such as the enclosure volume, the cone diameter, the moving mass and the very crucial “force factor”. For loudspeakers in small cabinets the results of this design procedure appear to be quite inefficient, especially at low frequencies. This paper describes a new solution to this problem. It consists of the combination of a highly non-linear preprocessing of the audio signal and the use of a so called low-force-factor loudspeaker. This combination yields a strongly increased efficiency, at least over a limited frequency range, at the cost of a somewhat altered sound quality. An analytically tractable optimality criterion has been defined and has been verified by the design of an experimental loudspeaker. This has a much higher efficiency and a higher sensitivity than current low-frequency loudspeakers, while its cabinet can be much smaller.


2018 ◽  
Vol 230 (3) ◽  
pp. 965-977
Author(s):  
Akintoye Olumide Oyelade ◽  
Obanishola Mufutau Sadiq ◽  
Omotayo A. Fakinlede

2020 ◽  
Vol 635 ◽  
pp. A76 ◽  
Author(s):  
L. Bondonneau ◽  
J.-M. Grießmeier ◽  
G. Theureau ◽  
A. V. Bilous ◽  
V. I. Kondratiev ◽  
...  

Context. To date, only 69 pulsars have been identified with a detected pulsed radio emission below 100 MHz. A LOFAR-core LBA census and a dedicated campaign with the Nançay LOFAR station in stand-alone mode were carried out in the years 2014–2017 in order to extend the known population in this frequency range. Aims. In this paper, we aim to extend the sample of known radio pulsars at low frequencies and to produce a catalogue in the frequency range of 25–80 MHz. This will allow future studies to probe the local Galactic pulsar population, in addition to helping explain their emission mechanism, better characterising the low-frequency turnover in their spectra, and obtaining new information about the interstellar medium through the study of dispersion, scattering, and scintillation. Methods. We observed 102 pulsars that are known to emit radio pulses below 200 MHz and with declination above −30°. We used the Low Band Antennas (LBA) of the LOw Frequency ARray (LOFAR) international station FR606 at the Nançay Radio Observatory in stand-alone mode, recording data between 25 and 80 MHz. Results. Out of our sample of 102 pulsars, we detected 64. We confirmed the existence of ten pulsars detected below 100 MHz by the LOFAR LBA census for the first time (Bilous et al. 2020, A&A, 635, A75) and we added two more pulsars that had never before been detected in this frequency range. We provided average pulse profiles, DM values, and mean flux densities (or upper limits in the case of non-detections). The comparison with previously published results allows us to identify a hitherto unknown spectral turnover for five pulsars, confirming the expectation that spectral turnovers are a widespread phenomenon.


Author(s):  
Sophie R. Kaye ◽  
Ethan D. Casavant ◽  
Paul E. Slaboch

Abstract Attenuating low frequencies is often problematic, due to the large space required for common absorptive materials to mitigate such noise. However, natural hollow reeds are known to effectively attenuate low frequencies while occupying relatively little space compared to traditional absorptive materials. This paper discusses the effect of varied outer diameter, and outer spacing on the 200–1600 Hz acoustic absorption of additively manufactured arrays of hollow cylinders. Samples were tested in a 10 cm diameter normal incidence impedance tube such that cylinder length was oriented perpendicular to the incoming plane wave. By varying only one geometric element of each array, the absorption due to any particular parameter can be assessed individually. The tests confirmed the hypothesis that minimizing cylinder spacing and maximizing cylinder diameter resulted in increased overall absorption and produced more focused absorption peaks at specific low frequencies. Wider cylinder spacing produced a broader absorptive frequency range, despite shifting upward in frequency. Thus, manipulating these variables can specifically target absorption for low frequency noise that would otherwise disturb listeners.


2016 ◽  
Vol 24 (02) ◽  
pp. 1550020 ◽  
Author(s):  
Q. Serra ◽  
M. N. Ichchou ◽  
J.-F. Deü

The transfer matrix method (TMM) is a famous analytic method in the vibroacoustic community. It is classically considered as a high frequency approach, because of the hypothesis of acoustic plane waves impinging on a flat infinite panel. Thus, it cannot take into account directly finite-size effects or lateral boundary conditions (BCs), and it needs specific algorithms to correct its results in the low frequency range. Within the transfer matrix framework, the use of finite elements makes it possible to generalize the range of applications of transfer approaches. Thus, the study of wave propagation in poroelastic media, in presence of lateral BCs can be carried out. The links between theses waves and the acoustic response of a sample are investigated. Finally, it shows that transfer approaches are not limited in the low frequency range, as usually stated. In fact, the validity of analytic transfer approaches depends more on the material and on the geometry than on the frequency range.


The vibrational absorption spectra of some substituted benzenes have been measured in the range 50 to 450 cm -1 . The compounds were measured as liquids, in solutions, as crystalline solidsat low temperature, and in polyethylene matrices. The extension of the infrared spectrum to very low frequencies has made it possible to determine new values for many fundamental vibrations. An assignment of all the vibrational frequencies in the low-frequency range has been made, from the infrared and Raman data, for p -dihalogeno-benzenes, p -halogenotoluenes, p -halogeno-nitrobenzenes, and for some mono-substituted benzenes. Some measurements have been made on the marked variation of intensity of the lowest frequency bending mode of p -dihalogeno-benzenes.


1994 ◽  
Vol 72 (3) ◽  
pp. 1061-1079 ◽  
Author(s):  
Z. M. Fuzessery

1. While hunting, the pallid bat uses passive sound localization at low frequencies to find terrestrial prey, and echolocation for general orientation. It must therefore process two different types of acoustic input at the same time. The pallid bat's echolocation pulse is a downward frequency-modulated (FM) sweep from 60 to 30 kHz. This study examined the response selectivity of single neurons in the pallid bat's central nucleus of the inferior colliculus (ICC) for FM sweeps, comparing the response properties of the high-frequency population, tuned to the biosonar pulse, with the low-frequency population, tuned below the pulse. The working hypothesis was that the high-frequency population would exhibit a response selectivity for downward FM sweeps that was not present in the low-frequency population. 2. Neurons were tested for their selectivity for FM sweep direction, duration, frequency range and bandwidth, and rate of frequency change. The extent to which they responded exclusively to tones, noise, and FM sweeps was also examined. Significant differences in the response properties of neurons in the two populations were found. In the low-frequency population, all neurons responded to tones, but only 50% responded to FM sweeps. Only 23% were selective for sweep direction. In the high-frequency population, all neurons responded to FM sweeps, but 31% did not respond to tones. Over one-half of this population was selective for sweep direction, and of those that were selective, all preferred the downward sweep direction of the biosonar pulse. A large percentage (31%) responded exclusively to downward sweeps, and not to tones or upward sweeps. None of the cells in either population responded to noise, or did so only at very high relative thresholds. 3. Both populations contained neurons that were selective for short stimulus durations that approximated the duration of the biosonar pulse, although the percentage was greater in the high-frequency population (58% vs. 20%). In the high-frequency population, 31% of the neurons tested for duration responded exclusively to both the sweep direction and duration of the biosonar pulse. 4. Downward FM-selective neurons, with one exception, were generally insensitive to the rate of frequency change of the FM sweep, as well as the frequency range and bandwidth of the sweep. They responded similarly to both the full 60- to 30-kHz sweep and to 5-kHz bandwidth portions of the full sweep.(ABSTRACT TRUNCATED AT 400 WORDS)


Sign in / Sign up

Export Citation Format

Share Document