scholarly journals Difference in bilateral digital volume pulse as a novel non-invasive approach to assessing arteriosclerosis in aged and diabetic subjects: A preliminary study

2017 ◽  
Vol 14 (3) ◽  
pp. 254-257 ◽  
Author(s):  
Hsien-Tsai Wu ◽  
Kuan-Wei Lee ◽  
Wen-Yao Pan ◽  
An-Bang Liu ◽  
Cheuk-Kwan Sun

Objective: This study aimed at validating photoplethysmography for assessing bilateral blood pressure differences through investigating the correlations of digital volume pulse with arteriosclerosis risk. Methods: Totally, 111 subjects (70 healthy and 41 diabetic) were recruited. Demographic, blood pressure and anthropometric data were recorded. Blood was collected for determining serum cholesterol, total triglyceride, total cholesterol, high-/low-density lipoprotein cholesterol, fasting blood sugar and glycated haemoglobin concentrations. Arterial stiffness was assessed with electrocardiogram-based pulse wave velocity, crest time and inter-digital volume pulse differences. Results: Receiver operating characteristic curve demonstrated high inter-digital volume pulse difference sensitivity to glycated haemoglobin level over 6.5%. Linear regression analysis demonstrated significant correlation between inter-digital volume pulse difference and electrocardiogram-based pulse wave velocity ( r = 0.692, p < 0.001). Compared with electrocardiogram-based pulse wave velocity, inter-digital volume pulse difference exhibited highly significant correlations with age, glycated haemoglobin level, pulse pressure, total cholesterol/high-density lipoprotein ratio, crest time, high-density lipoprotein and systolic blood pressure (all ps < 0.001). Conclusion: In conclusion, the results not only demonstrated successful application of a novel non-invasive waveform contour index, inter-digital volume pulse difference, in differentiating young from aged subjects and patients with good diabetic control from those with poor diabetic control but also validated its use in identifying arteriosclerosis risks. The results, therefore, endorse its domestic application as non-invasive tool for arteriosclerosis risk screening.

Sensors ◽  
2019 ◽  
Vol 19 (16) ◽  
pp. 3467 ◽  
Author(s):  
Vratislav Fabian ◽  
Lukas Matera ◽  
Kristyna Bayerova ◽  
Jan Havlik ◽  
Vaclav Kremen ◽  
...  

Cardiovascular diseases are one of most frequent cause of morbidity and mortality in the world. There is an emerging need for integrated, non-invasive, and easy-to-use clinical tools to assess accurately cardiovascular system primarily in the preventative medicine. We present a novel design for a non-invasive pulse wave velocity (PWV) assessment method integrated in a single brachial blood pressure monitor allowing for up to 100 times more sensitive recording of the pressure pulsations based on a brachial occlusion-cuff (suprasystolic) principle. The monitor prototype with built-in proprietary method was validated with a gold standard reference technique SphygmoCor VX device. The blood pressure and PWV were assessed on twenty-five healthy individuals (9 women, age (37 ± 13) years) in a supine position at rest by a brachial cuff blood pressure monitor prototype, and immediately re-tested using a gold standard method. PWV using our BP monitor was (6.67 ± 0.96) m/s compared to PWV determined by SphygmoCor VX (6.15 ± 1.01) m/s. The correlation between methods using a Pearson’s correlation coefficient was r = 0.88 (p < 0.001). The study demonstrates the feasibility of using a single brachial cuff build-in technique for the assessment of the arterial stiffness from a single ambulatory blood pressure assessment.


1995 ◽  
Vol 89 (3) ◽  
pp. 247-253 ◽  
Author(s):  
E. D. Lehmann ◽  
K. D. Hopkins ◽  
R. L. Jones ◽  
A. G. Rudd ◽  
R. G. Gosling

1. Non-invasive aortic compliance measurements have been used previously to assess the distensibility of the aorta in several pathological conditions associated with increased cardiovascular risk. We set out to establish whether aortic compliance is abnormal in patients with stroke. 2. Pulse wave velocity measurements of thoracoabdominal aortic compliance were made in 20 stroke patients and 25 age- and sex-matched hospitalized, non-stroke control subjects putatively free of cardiovascular disease. Since compliance varies with non-chronic changes in blood pressure, a blood pressure corrected index of aortic distensibility, Cp, was calculated. 3. Aortic compliance was significantly reduced in patients with stroke compared with non-stroke control subjects (0.46 ± 0.27 versus 0.86 ± 0.34%/10 mmHg, P < 0.0002), corresponding with higher values for pulse wave velocity. Stroke patients also had significantly higher systolic and diastolic blood pressures (P < 0.02 and P < 0.002 respectively) and total cholesterol levels (P < 0.004) than the control subjects. Calculation of Cp did not alter the observation of stiffer aortas in the stroke cohort (P < 0.0007). 4. In both stroke patient and control cohorts, as expected, inverse trends were observed between aortic compliance and blood pressure. Also as expected, in the control group Cp values did not show a relationship with blood pressure (r = 0.02, P = 0.092, not significant). However, in the stroke cohort a marked dependence of Cp on blood pressure was observed (r = −0.48, P = 0.03). 5. Transoesophageal echocardiographic studies have recently identified advanced atherosclerosis in the ascending aorta as a possible source of cerebral emboli and an independent risk factor for ischaemic stroke. Our observations of significantly stiffer thoracoabdominal aortas in patients with stroke lead us to hypothesize that a totally non-invasive assessment of aortic compliance may potentially prove a useful surrogate marker of such atherosclerotic risk. 6. Blood pressure-corrected indices of arterial elastic properties based on normotensive models are widely applied in the literature. Our observation that these indices exhibit a considerable blood pressure dependence leads us to urge caution in the use of such corrections, especially in hypertensive patients.


2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Chung-Jen Lee ◽  
Ji-Hung Wang ◽  
Yu-Chih Chen ◽  
Mei-Ling Chen ◽  
Chiu-Fen Yang ◽  
...  

Osteopontin (OPN) is involved in the regulation of vascular calcification processes. The aim of this study was to evaluate the relationship between fasting serum OPN concentration and carotid-femoral pulse wave velocity (cfPWV) in geriatric persons. Fasting blood samples were obtained from 93 geriatric persons. cfPWV were performed by SphygmoCor system. Serum OPN levels were measured using a commercially available enzyme-linked immunosorbent assay. Geriatric adults who had diabetes (P=0.007) or dyslipidemia (P=0.029) had higher cfPWV levels than those without diabetes or dyslipidemia. The univariable linear regression analysis showed that age (P=0.002), waist circumference (P=0.048), body mass index (P=0.004), systolic blood pressure (P=0.001), diastolic blood pressure (P=0.036), pulse pressure (P=0.017), creatinine (P=0.002), and log-OPN level (P=0.001) were positively correlated with cfPWV levels, while the high-density lipoprotein cholesterol (HDL-cholesterol) level (P=0.007) and glomerular filtration rate (P=0.001) were negatively correlated with cfPWV levels among the geriatric adults. Multivariable forward stepwise linear regression analysis of the significant variables also showed that log-OPN (β=0.233,R2=0.123, regression coefficient: 1.868,P=0.011) was still an independent predictor of cfPWV levels in geriatric persons.


1952 ◽  
Vol 30 (2) ◽  
pp. 125-129
Author(s):  
J. P. Adamson ◽  
J. Doupe

Intra-arterial pressures and pulse wave velocities were measured in 18 subjects whose auscultatory diastolic pressures ranged from 45 to 120 mm. Hg. Various methods were used to lower the blood pressure in the hypertensive and to raise it in nonhypertensive subjects so that pulse wave velocities might be compared in all subjects at a common diastolic pressure. The pulse wave velocities were calculated for a diastolic pressure of 80 mm. Hg. No significant differences were found between hypertensive and nonhypertensive subjects. It was concluded that a defect of arterial elasticity as gauged by pulse wave velocity is not a factor in the pathogenesis of hypertension.


2021 ◽  
Vol 23 (1) ◽  
Author(s):  
Max J. van Hout ◽  
Ilona A. Dekkers ◽  
Jos J. Westenberg ◽  
Martin J. Schalij ◽  
Ralph L. Widya ◽  
...  

Abstract Background Aortic stiffness, assessed through pulse wave velocity (PWV), is an independent predictor for cardiovascular disease risk. However, the scarce availability of normal and reference values for cardiovascular magnetic resonance imaging (CMR) based PWV is limiting clinical implementation. The aim of this study was to determine normal and reference values for CMR assessed PWV in the general population. Methods From the 2,484 participants of the Netherlands Epidemiology of Obesity (NEO) study that have available CMR-PWV data, 1,394 participants free from cardiovasculard disease, smokers or treatment for diabetes, hypertension or dyslipidaemia were selected (45–65 years, 51% female). Participants were divided into sex, age and blood pressure (BP) subgroups. Normal values were specified for participants with a BP < 130/80 mmHg and reference values for elevated BP subgroups (≥ 130/80 and < 140/90 mmHg; and ≥ 140/90 mmHg). Differences between groups were tested with independent samples t-test or ANOVA. Due to an oversampling of obese individuals in this study, PWV values are based on a weighted analysis making them representative of the general population. Results Normal mean PWV was 6.0 m/s [95% CI 5.8–6.1]. PWV increased with advancing age and BP categories (both p < 0.001). There was no difference between sex in normal PWV, however in the BP > 140/90 mmHg women had a higher PWV (p = 0.005). The interpercentile ranges were smaller for participants < 55 years old compared to participants ≥ 55 years, indicating an increasing variability of PWV with age. PWV upper limits were particularly elevated in participants ≥ 55 years old in the high blood pressure subgroups. Conclusion This study provides normal and reference values for CMR-assessed PWV per sex, age and blood pressure category in the general population.


2021 ◽  
Vol 10 (6) ◽  
pp. 1198
Author(s):  
Victor N. Dorogovtsev ◽  
Dmitry S. Yankevich ◽  
Nandu Goswami

The objective of our study was to identify blood pressure (BP) and pulse wave velocity (PWV) changes during orthostatic loading, using a new the head-up tilt test (HUTT), which incorporates the usage of a standardized hydrostatic column height. Methods: 40 healthy subjects 20–32 years performed HUTT, which was standardized to a height of the hydrostatic column at 133 cm. Exposure time was 10 min in each of 3 positions: horizontal supine 1, HUTT, and horizontal supine 2. The individual tilt up angle made it possible to set the standard value of the hydrostatic column. Hemodynamic parameters were recorded beat to beat using “Task Force Monitor 3040 i”, pulse-wave velocity (PWV) was measured with a sphygmograph–sphygmomanometer VaSera VS1500N. Results: Orthostatic loading caused a significant increase in heart rate (HR) and a decrease in stroke volume (SV) (p < 0.05) but no significant reductions in cardiac output, changes in total vascular resistance (TVR), or BP. An analysis of personalized data on systolic blood pressure (SBP) changes in tilt up position as compared to horizontal position (ΔSBP) revealed non-significant changes in this index in 48% of subjects (orthostatic normotension group), in 32% there was a significant decrease in it (orthostatic hypotension group) and in 20% there was a significant increase in it (orthostatic hypertension group). These orthostatic changes were not accompanied by any clinical symptoms and/or syncope. During HUTT, all subjects had in the PWV a significant increase of approximately 27% (p < 0.001). Conclusion: The new test protocol involving HUTT standardized to a height of hydrostatic column at 133 cm causes typical hemodynamics responses during orthostatic loading. Individual analysis of the subjects revealed subclinical orthostatic disorders (OSD) in up to 52% of the test persons. During HUTT, all test subjects showed a significant increase in PWV. The new innovative HUTT protocol can be applied in multi-center studies in healthy subjects to detect preclinical forms of orthostatic disorders under standard gravity load conditions.


Sign in / Sign up

Export Citation Format

Share Document