scholarly journals Screening for aneurysms of the abdominal aorta using a simple screening device

2020 ◽  
Vol 12 (1) ◽  
Author(s):  
J. W. Brakel ◽  
T. A. Berendsen ◽  
P. M. C. Callenbach ◽  
J. van der Burgh ◽  
R. J. Hissink ◽  
...  

Abstract Introduction Several countries advocate screening for aneurysms of the abdominal aorta (AAA) in selected patients. In the Netherlands, routine screening is currently under review by the National Health Council. In any screening programme, cost-efficiency and accuracy are key. In this study, we evaluate the Aorta Scan (Verathon, Amsterdam, Netherlands), a cost-effective and easy-to-use screening device based on bladder scan technology, which enables untrained personnel to screen for AAA. Methods We subjected 117 patients to an Aorta Scan and compared the results to the gold standard (abdominal ultrasound). We used statistical analysis to determine sensitivity and specificity of the Aorta Scan, as well as the positive and negative predictive values, accuracy, and inter-test agreement (Kappa). Results Sensitivity and specificity were 0.86 and 0.98, respectively. Positive predictive value was 0.98 and negative predictive value was 0.88. Accuracy was determined at 0.92 and the Kappa value was 0.85. When waist–hip circumferences (WHC) of > 115 cm were excluded, sensitivity raised to 0.96, specificity stayed 0.98, positive and negative predictive value were 0.98 and 0.96, respectively, accuracy to 0.97, and Kappa to 0.94. Conclusion Herein, we show that the Aorta Scan is a cost-effective and very accurate screening tool, especially in patients with WHC below 115 cm, which makes it a suitable candidate for implementation into clinical practice, specifically in the setting of screening selected populations for the presence of AAA.

2021 ◽  
Vol 9 (B) ◽  
pp. 1128-1134
Author(s):  
Saif Hassan Alrasheed ◽  
Amel Mohamed Yousif ◽  
Majid A. Moafa ◽  
Abd Elaziz Mohamed Elmadina ◽  
Mohammad Alobaid

BACKGROUND: Sheard and Percival assumed that symptoms from latent strabismus can be avoided if the relevant fusional vergence is adequate to support the heterophoria. AIM: The aim of the study was to determine the sensitivity and specificity of Sheard’s and Percival’s criterion for the diagnosis of heterophoria. METHODS: A cross-sectional hospital-based study was performed at Al-Neelain Eye Hospital Khartoum, Sudan from February to October 2019. Heterophoria was measured using Maddox Wing and fusional vergence using a prism bar. Thereafter, Sheard’s and Percival’s criteria were used for the diagnosis of heterophoria. RESULTS: A total of 230 participants (age = 15–30 years; mean age = 19.34 ± 3.325 years) were recruited for this study. The Sheard’s criteria showed a high sensitivity of 87.2% and a low specificity of 8.0% for the diagnosing of exophoria, with positive and negative predictive values of 65.5% and 26%, respectively. The criteria showed a relatively low sensitivity of 77.8% and a specificity of 9.0% in the diagnosis of esophoria, with a positive and negative predictive values of 56% and 20%, respectively. Percival criteria showed high sensitivity 84.2% and low specificity 9.1% in diagnosing esophoria, with a positive and negative predictive value of 61.5% and 25%, respectively. On the other hand, the criteria showed low sensitivity 67.4% and specificity 13.8% in diagnosing exophoria, with positive and negative predictive value 61.9% and 17%, respectively. CONCLUSION: Sheard’s and Percival’s criteria are useful in diagnosing binocular vision problems. Sheard’s criteria are accurate in diagnosing near exophoria and Percival’s criteria are more accurate in diagnosing near esophoria. Therefore, these criteria provide good clues and predictions for the diagnosis of binocular vision problems.


BMC Cancer ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Blanca Murillo-Ortiz ◽  
Abraham Hernández-Ramírez ◽  
Talia Rivera-Villanueva ◽  
David Suárez-García ◽  
Mario Murguía-Pérez ◽  
...  

Abstract Background Some evidence has shown that malignant breast tumours have lower electrical impedance than surrounding normal tissues. Electrical impedance could be used as an indicator for breast cancer detection. The purpose of our study was to analyse the sensitivity and specificity of electrical impedance mammography (EIM) and its implementation for the differential diagnosis of pathological lesions of the breast, either alone or in combination with mammography/ultrasound, in 1200 women between 25 and 70 years old. Methods This study is a prospective, cross-sectional epidemiological observational study of serial screening. The women were invited to participate and signed a consent letter. Impedance imaging of the mammary gland was evaluated with the computerized mammography equipment of MEIK electroimpedance v.5.6. (0.5 mA, 50 kHz), developed and manufactured by PKF SIM-Technika®. The successful identification of breast cancer along with the sensitivity, specificity, and positive and negative predictive values of EIM were determined as follows: % sensitivity; % specificity; % positive predictive value (PPV); and % negative predictive value (NPV). Results EIM had a sensitivity of 85% and a specificity of 96%; the positive predictive value was 12%, and the negative predictive value was 99%. Seven cases were biopsy confirmed cancers. Significant correlations between the electrical conductivity index and body mass index (BMI) (p = 0.04) and patient age were observed (p = 0.01). We also observed that the average conductivity distribution increased according to age group (p = 0.001). We used the chi-squared test to assess the interactions between percent density and BMI (normal < 25 kg/m2 (n = 310), overweight 25–29.9 kg/m2 (n = 418) and obese ≥30 (n = 437)) (p <  0.05). The patients with a diagnosis of mammary carcinoma had a BMI of 35.51 kg/m2. Conclusions Our results demonstrate that the use of monofrequency electrical impedance mammography (EIM) in the detection of breast cancer had a sensitivity and specificity of 85 and 96%, respectively. These findings may support future research in the early detection of breast cancer. EIM is a non-radiation method that may also be used as a screening method for young women with dense breasts and a high risk of developing breast cancer.


2011 ◽  
Vol 3 (2) ◽  
pp. 63-66
Author(s):  
Geeta Durdi ◽  
Kamal Patil ◽  
Lakshita Lumb

ABSTRACT Objectives To detect and compare the sensitivity and specificity of downstaging and visual inspection with acetic acid (VIA) and with Lugol's iodine (VILI). Methods Screening with downstaging, VIA and VILI were done on 680 women who fulfilled the inclusion criteria at a primary health center attached to the university hospital, over a period of one year. Those who had abnormal results in downstaging, VIA and VILI were biopsied and sensitivity, specificity, negative predictive value and positive predictive value were calculated. Results The sensitivities of downstaging, VIA and VILI were 54.55, 63.64 and 90.91% and specificities were 93.42, 95.07 and 97.46% respectively. The positive predictive value of downstaging, VIA and VILI were 12.01, 17.5 and 35.7% and negative predictive values were 99.2, 99.37 and 98.85% respectively. Conclusion VIA and VILI are suitable primary screening procedures as compared to downstaging because of high sensitivity and specificity. The negative predictive value of downstaging, VIA and VILI is better than the positive predictive value. Downstaging can be used in rural areas where acetic acid and Lugol's iodine are not available.


Author(s):  
Jolanta Nawrocka-Rutkowska ◽  
Iwona Szydłowska ◽  
Aleksandra Rył ◽  
Sylwester Ciećwież ◽  
Magdalena Ptak ◽  
...  

Background: Chronic pelvic pain affects approximately 15% of reproductive age women. It is mainly caused by adhesions (20–40%). Despite CPP being the main symptom of endometriosis, the disease is confirmed by laparoscopy only in 12–18% of cases. The aim of this study was to evaluate the results of laparoscopy in women with CCP and to assess the sensitivity and specificity of elements of an interview and clinical examination. Materials and methods: The study included 148 women with CPP. Each patient underwent laparoscopy. In laparoscopy, the presence of endometriosis and/or peritoneal adhesions was confirmed. Then, the sensitivity and specificity and the positive and negative predictive value of endometriosis symptoms or abnormalities in the gynecological examination were statistically calculated. Results: After previous surgery, adhesions were found in almost half (47%) of patients. In patients without a history of surgery, adhesions were diagnosed in 6.34% of patients. Endometriosis without coexisting adhesions was more often diagnosed in women without previous surgery (34.9%), compared to 10.58% in the group with a history of surgery (p < 0.05). Conclusions: Intraperitoneal adhesions are most common in women after pelvic surgery and with chronic ailments. The best results for sensitivity, specificity, positive predictive value, and negative predictive value in the diagnosis of endometriosis are found in women with irregular menstruations during which the pain increases. Laparoscopy still remains the primary diagnostic and therapeutic method for these women.


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Author(s):  
Nicolas Bovo ◽  
Shahan Momjian ◽  
Renato Gondar ◽  
Philippe Bijlenga ◽  
Karl Schaller ◽  
...  

Abstract Objective The objective of this study was to determine the performance of the standard alarm criterion of motor evoked potentials (MEPs) of the facial nerve in surgeries performed for resections of vestibular schwannomas or of other lesions of the cerebellopontine angle. Methods This retrospective study included 33 patients (16 with vestibular schwannomas and 17 with other lesions) who underwent the resection surgery with transcranial MEPs of the facial nerve. A reproducible 50% decrease in MEP amplitude, resistant to a 10% increase in stimulation intensity, was applied as the alarm criterion during surgery. Facial muscular function was clinically evaluated with the House–Brackmann score (HBS), pre- and postsurgery at 3 months. Results In the patient group with vestibular schwannoma, postoperatively, the highest sensitivity and negative predictive values were found for a 30% decrease in MEP amplitude, that is, a criterion stricter than the 50% decrease in MEP amplitude criterion, prone to trigger more warnings, used intraoperatively. With this new criterion, the sensitivity would be 88.9% and the negative predictive value would be 85.7%. In the patient group with other lesions of the cerebellopontine angle, the highest sensitivity and negative predictive values were found equally for 50, 60, or 70% decrease in MEP amplitude. With these criteria, the sensitivities and the negative predictive values would be 100.0%. Conclusion Different alarm criteria were found for surgeries for vestibular schwannomas and for other lesions of the cerebellopontine angle. The study consolidates the stricter alarm criterion, that is, a criterion prone to trigger early warnings, as found previously by others for vestibular schwannoma surgeries (30% decrease in MEP amplitude).


2020 ◽  
Vol 7 (3) ◽  
pp. 125-128
Author(s):  
Rida Salman ◽  
Mira Alsheikh ◽  
Rim Ismail

Background and aims: The diagnostic workup for pulmonary embolism (PE) includes D-dimer assay and computed tomographic angiography. Several D-dimer assays have been approved for PE diagnosis with different sensitivity and specificity. We aimed to study the sensitivity and specificity of the quantitative latex agglutination D-dimer assay used in a referral teaching hospital in Lebanon for the diagnosis of acute PE. Methods: Using a retrospective chart review, we studied 300 patients who had D-dimer test at Rafik Hariri University Hospital in the period between January 1, 2012 and December 31, 2013. Accordingly, 93 patients had a CT angiography after being suspected to have acute PE. A statistical table 2*2 was used to compare the results of CT angiography and D-dimer test. Results: Thirteen patients (13.97%) had PE and 60 patients (64.51%) had positive D-dimer test. Quantitative latex agglutination D-dimer assay had a sensitivity of 69%, specificity of 36%, and negative predictive value of 88%. False positive ratio was also 64%. Moreover, the receiver operating characteristic (ROC) curve was obtained with an area under the curve measuring 0.527. Conclusion: Quantitative latex agglutination D-dimer assay has a high negative predictive value; thus, it can exclude a PE diagnosis if it is associated with low clinical pretest probability.


2021 ◽  
Vol 24 (2) ◽  
pp. 196-203
Author(s):  
Elahe Fini ◽  
◽  
Neda Nasirian ◽  
Bahram Hosein Beigy ◽  
◽  
...  

Background and Aim: Ovarian cancer is among the most common cancers in women worldwide. CA125 is the most frequent biomarker used in the screening for ovarian cancer. CA125 has no high sensitivity and specificity as a screening test in the medical community; however, because of being simple and noninvasive, it is almost always requested for evaluation and ruling out cancer. It plays an important role in the treatment and post-treatment process, the prediction of prognosis, and the relapse of the disease. The present study aimed to determine the relationship between a high level of CA125 tumor marker and ovarian cancer by detecting spesivity, sensivity, positive and negative predictive values. Methods & Materials: In this cross-sectional study, all cases undergoing CA125 test in Velayat Hospital in 2017-1028 were evaluated for having ovarian cancer. In addition, the CA125 level was compared between healthy individuals and patients with ovarian cancer. Finally, the obtained data were analyzed using SPSS. Ethical Considerations: The present study was approved by the Qazvin University of Medical Sciences (Ethics Code: IR.QUMS.REC.1396.316). Results: In this study, 35.3% of the study participants received a definite diagnosis of ovarian cancer. Generally, CA125 values were negative in 41.8% and positive in.58.2% of the study subjects. The sensitivity of the test was measured as 80.1%, the specivity as 53.6%, the positive predictive value equaled 48.4%, and the negative predictive value was measured as 83%. There was a significant relationship between age and the presence of ovarian cancer, and serum CA125 levels. Conclusion: The present study suggested that age and the serum level of CA125 were statistically significant. Finally, CA125 levels were significantly related to ovarian cancer. It provided moderate specivity and specivity as well as low positive predictive value and high negative predictive value as a tumor marker; it is valuable for ruling out of tumor but not appropriate as a screening test.


2021 ◽  
Vol 70 (2) ◽  
pp. 89-96
Author(s):  
Jiří Hložek ◽  
Jan Rotnágl ◽  
Jaromír Astl

Paresis of the recurrent laryngeal nerve (RLN) is one of the serious complications of thyroid and parathyroid gland surgery. The intraoperative neural monitoring (IONM) enables to verify the functionality of RLN. The aim of this study is to compare the incidence of postoperative RLN palsy in patients who underwent surgery with and without the use of IONM RLN and to evaluate the positive and negative predictive values, sensitivity, specifi city and accuracy of the method. Methods: Retrospective analysis of thyroid gland surgeries performed within the period from 1. 7. 2016 to 1. 7. 2018. A total of 467 operations were performed (780 nerves exposed). One hundred and thirty procedures (215 nerves) were carried out without IONM (group A). In total, 337 procedures (565 nerves) were performed with IONM (group B). Results: In group A, unilateral postoperative RLN paresis occurred in 7 cases (3.26%); 6 of them were temporary (2.79%) and 1 was permanent (0.47%). In group B, unilateral postoperative RLN paresis occurred in 33 cases (5.84%); 32 of them were temporary (5.66%) and 1 was permanent (0.18%). The incidence of postoperative RLN paresis related to the use of IONM was not considered statistically signifi cant. (Chi-square test: P = 0.146; Fisher‘s exact test: P = 0.2015, P = 0.4715). The sensitivity, specifi city, positive predictive value, negative predictive value and accuracy were 78.79%, 99.25%, 86.67%, 98.69%, and 98.05%, respectively. There was no case of bilateral postoperative RLN paresis. Conclusion: There was no statistically significant diff erence in the incidence of postoperative RLN palsy in patients who underwent surgery with IONM compared to the group without IONM. The high negative predictive value, specifi city and accuracy indicate high reliability of the method. The IONM provides the surgeon with valuable information regarding the functional status of the nerve. This knowledge allows for changing the operative strategy during the procedure. Keywords: intraoperative neural monitoring – IONM – recurrent laryngeal nerve injury – recurrent laryngeal nerve – thyroid surgery


Sign in / Sign up

Export Citation Format

Share Document