Seismic and flood-resistance capacity promotion and service life elongation method for existing bridge by employing substructure replacement technique

Author(s):  
Dyi-Wei Chang ◽  
Dzong-Chwang Dzeng ◽  
Chih-Pin Chang ◽  
Ming-Yi Yu

Author(s):  
Robert A. Grant ◽  
Laura L. Degn ◽  
Wah Chiu ◽  
John Robinson

Proteolytic digestion of the immunoglobulin IgG with papain cleaves the molecule into an antigen binding fragment, Fab, and a compliment binding fragment, Fc. Structures of intact immunoglobulin, Fab and Fc from various sources have been solved by X-ray crystallography. Rabbit Fc can be crystallized as thin platelets suitable for high resolution electron microscopy. The structure of rabbit Fc can be expected to be similar to the known structure of human Fc, making it an ideal specimen for comparing the X-ray and electron crystallographic techniques and for the application of the molecular replacement technique to electron crystallography. Thin protein crystals embedded in ice diffract to high resolution. A low resolution image of a frozen, hydrated crystal can be expected to have a better contrast than a glucose embedded crystal due to the larger density difference between protein and ice compared to protein and glucose. For these reasons we are using an ice embedding technique to prepare the rabbit Fc crystals for molecular structure analysis by electron microscopy.



1993 ◽  
Vol 06 (02) ◽  
pp. 85-92 ◽  
Author(s):  
G. L. Coetzee

SummaryThe immediate postoperative biomechanical properties of an “underand-over” cranial cruciate ligament (CCL) replacement technique consisting of fascia lata and the lateral onethird of the patellar ligament, were compared with that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The right CCL in twelve adult dogs was dissected out and replaced with an autograft. The contralateral, intact CCL served as the control. In group A, the graft was secured to the lateral femoral condyle with a spiked washer and screw. In group B the intracapsular graft was secured to the lateral femoro-fabellar ligament, and the remainder to the patellar tendon. Both CCL replacement techniques exhibited a 2.0 ± 0.5 mm anterior drawer immediately after the operation. After skeletonization of the stifles, the length and cross-sectional area of the intact CCL and CCL substitutes were determined. Each bone-ligament unit was tested in linear tension to failure at a fixed distraction rate of 15 mm/s with the stifle in 120° flexion. Data was processed to obtain the corresponding material parameters (modulus, stress and strain in the linear loading region, and energy absorption to maximum load).The immediate postoperative structural and material properties of the “under-and-over” cranial cruciate ligament replacement technique with autogenous fascia lata, were compared to that of a modified intra- and extracapsular “under-and-over-the-top” (UOTT) method. The combined UOT T technique was slightly stronger (6%), but allowed 2.8 ± 0.9 mm more cranial tibial displacement at maximum linear force.



1997 ◽  
Vol 503 ◽  
Author(s):  
H. Jiang ◽  
M. K. Davis ◽  
R. K. Eby ◽  
P. Arsenovic

ABSTRACTPhysical properties and structural parameters have been measured for ropes of nylon 6 as a function of the number of use operations. The fractional content of the α crystal form, sound velocity, birefringence, tensile strength and length all increase systematically and significantly with increasing the number of use operations. The fractional content of the γ crystal form and fiber diameter decrease with use. These trends indicate that the measurement of such properties and structural parameters, especially the length, provide a possible basis for establishing a reliable, rapid, and convenient nondestructive characterization method to predict the remaining service life of nylon 6 ropes.



Author(s):  
N.A. Makhutov ◽  
◽  
Ya.M. Fridlyand ◽  
A.A. Raspopov ◽  
M.V. Lisanov ◽  
...  


2018 ◽  
Vol 4 (1) ◽  
pp. 165
Author(s):  
Herry Prabowo ◽  
Mochamad Hilmy

The assessment of the service life of concrete structures using the durability design approach is widely accepted nowadays. It is really encouraged that a simulation model can resemble the real performance of concrete during the service life. This paper investigates the concrete carbonation through probabilistic analysis. Data regarding Indonesian construction practice were taken from Indonesian National Standard (SNI). Meanwhile, data related to Indonesian weather condition for instance humidity and temperature are taken from local Meteorological, Climatological, and Geophysical Agency from 2004 until 2016. Hopefully the results can be a starting point for durability of concrete research in Indonesia.



2019 ◽  
Vol 12 (1) ◽  
pp. 56-62 ◽  
Author(s):  
A. O. Nedosekin ◽  
A. V. Smirnov ◽  
D. P. Makarenko ◽  
Z. I. Abdoulaeva

The article presents new models and methods for estimating the residual service life of an autonomous energy system, using the functional operational risk criterion (FOR). The purpose of the article is to demonstrate a new method of durability evaluation using the fuzzy logic and soft computing framework. Durability in the article is understood as a complex property directly adjacent to the complex property of system resilience, as understood in the Western practice of assessing and ensuring the reliability of technical systems. Due to the lack of reliable homogeneous statistics on system equipment failures and recoveries, triangular fuzzy estimates of failure and recovery intensities are used as fuzzy functions of time based on incomplete data and expert estimates. The FOR in the model is the possibility for the system availability ratio to be below the standard level. An example of the evaluation of the FOR and the residual service life of a redundant cold supply system of a special facility is considered. The transition from the paradigm of structural reliability to the paradigm of functional reliability based on the continuous degradation of the technological parameters of an autonomous energy system is considered. In this case, the FOR can no longer be evaluated by the criterion of a sudden failure, nor is it possible to build a Markov’s chain on discrete states of the technical system. Assuming this, it is appropriate to predict the defi ning functional parameters of a technical system as fuzzy functions of a general form and to estimate the residual service life of the technical system as a fuzzy random variable. Then the FOR is estimated as the possibility for the residual life of the technical system to be below its warranty period, as determined by the supplier of the equipment.



2019 ◽  
Vol 12 (1) ◽  
pp. 18-21
Author(s):  
V. A. Tikhonov

The influence of the periodicity of diagnostic measurements on the operational state of high-voltage transformers is considered. Examples of defects of switching devices of converter transformers and methods for their detection are given. The rationale for the importance of recognition of defects at an early stage of their occurrence is given. The influence of the multiplicity of overvoltages on the service life of converter transformers in the aluminum industry is investigated. Based on the analysis of the service life of converter transformers of one of the powerful aluminum plants, where 83% of converter transformers have exhausted their standard service life, it is shown that in 40% of cases it would be possible to avoid their failures, with timely detection and elimination of emerging defects. Examples of defects of OLR (on-load regulators) of converter transformers and methods for their detection are given. The importance of recognition of defects at an early stage of their occurrence is substantiated. A method for chromatographic analysis of dissolved gases in transformer oil has been developed for the qualitative determination of defects and ways to eliminate them. Examples of diagnostics of converter transformers at operating voltage and working load are given, providing the best quality operational characteristics of converter transformers. The periodicity of diagnostic measurements and the reduction of defects and failures has been substantiated. The question of diagnosing the state of the converter transformer TDNP-40000/10 at an enterprise of the aluminum industry is investigated. Currently, diagnostic methods are being developed based on chromatographic analysis of dissolved gases in transformer oil. The presented method of evaluating the operating parameters of transformers allows for the safe operation of high-voltage transformers and enables to increase the reliability of the power supply scheme of aluminum industry plants.



2019 ◽  
Author(s):  
Gregory T. Schueneman ◽  
Steven J. Lacher ◽  
Christopher G. Hunt
Keyword(s):  


Sign in / Sign up

Export Citation Format

Share Document